My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179147_2140 E. 17TH - Plan
PBA
>
Building
>
Plans
>
S
>
Seventeenth St
>
2140 E Seventeenth St
>
10179147_2140 E. 17TH - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:12 PM
Creation date
10/25/2020 5:15:00 PM
Metadata
Fields
Template:
Plan
Permit Number
10179147
Full Address
2140 E Seventeenth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
51 SIGN COMPONENTS MANUAL (SAM)November 14,2012 <br />LED Driver with Class 2 Output, Models GEPS12D-60U, GEPS24D-80U. <br />1. These LED Drivers have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 output. <br />2. These products are provided with the following electrical ratings: <br />Model No.Input Voltage (V Input Freq Input Current Output Voltage Output Current Output <br />ac) (HZ) (A) (V dc) (A) Power (W) <br />GEPS24D-80U 100-277 50/60 1.1 24 3.3 80 <br />GEPS12D-60U 100-277 |50/60 0.85 12 5.0 60 <br />3. The load powered by the Class 2 output of the LED drivers are suitable for use in dry, damp and wet locations. <br />4. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and <br />minimum 2 inches spacing to top of enclosure. <br />5. In the end product, LED Drivers shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less <br />than 4 inches (102mm) apart when arranged otherwise. <br />6. These products shall be enclosed in the end product. <br />7. The unit is intended for being used in permanently wired signs. <br />8. The suitability of output leads, rated No. 24 AWG minimum, rated 80°C minimum, 600 V, shall be determined in end product <br />use. <br />9. These units may provided with Dimming Input (Purple and Gray wires) to control output current range, the suitability shall be <br />determined in each end-use application. <br />10. These products are intended for use in dry and damp locations <br />LED Driver with Class 2 Output, Model 1110PS-60S. <br />1. These LED drivers have been evaluated using resistive load resulting in the electrical input and output noted on page 1. <br />2. These LED drivers are provided with Class 2 output. <br />3. These LED drivers are intended to be operated in a maximum ambient (Ta) noted as below: <br />Model Ta (°C) <br />LD-60-UV-1214V 40 <br />4. These LED drivers are intended for use in dry and damp locations except that models LD-60-UV-1214V and LD-60-UV-1214\A <br />SC are suitable for dry location only. <br />5. These LED drivers are provided with 18 AWG AWM input and output leads. The suitability of the wiring and the need for a <br />suitable enclosure shall be considered in the end product. <br />6. These LED drivers are intended to be operated on a maximum 20 A branch circuit. <br />7. The need of the grounding means shall be determined in the end product. <br />8. These LED drivers shall be enclosed within a suitable end product enclosure. <br />9. For model LD-60-UV-24V-DIW, the conduit knockout test was not conducted. The suitability is to be determined in end product. <br />10. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />11. In the end product, LED Drivers shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less <br />than 4 inches (102mm) apart when arranged otherwise. <br />LED Driver with Class 2 Output, Model GEPS12-180U. <br />1. The output (Red/Black) of each unit complies with Class 2 criteria of UL 1310. <br />2. The device is provided with 18 AWG input and output leads. The suitability of input and output connections shall be determined <br />in end-use application. <br />3. The suitability of grounding means shall be determined by end product. <br />4. The device is not intended for field wiring used. <br />5. The device is intended to be connected to a maximum 20 A branch circuit. <br />6. The devices are of the constant current type that requires the proper number of LED modules and controllers that does not <br />exceed the maximum output voltage/current. <br />7. The measured maximum external enclosure temperature (Tc) is 77.2 degree C when the room ambient temperature are 60 <br />degree C. The suitability shall be determined in end application. <br />8. The devices employ input surge suppression protection, Cat. No. S14K385E2K1 under UL File E321126, which is intended end- <br />use SPD type 2. The suppressed voltage rating is 385 Vac. The suitability of use of this component shall be determined in the <br />end-product application. <br />9. No mechanical test has been conducted for the models and the metal chassis is considered as dead metal. The devices shall <br />be mounted in the intended manner in an enclosure, having adequate strength and thickness with acceptable spacing being <br />provided. <br />10. The device has been evaluated for dry and damp locations use only. <br />11. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />12. In the end product, LED Drivers shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less <br />than 4 inches (102mm) apart when arranged otherwise. <br />LED Driver with Class 2 Output, Model No. GEPSJB60. <br />1. The j-Box Enclosure has been evaluated only for use and connection to LED Class 2 Drivers GEPS 12-60, GEPS12O-604 <br />GEPS24-80, and GEPS24O-80U. <br />2. These products complete the electrical enclosure when installed over the primary wiring of the LED driver. <br />3. The suitability of the mounting shall be determined in end use application. <br />4. The enclosure has been evaluated only for use in Dry and damp locations only <br />5. Supply connection shall be determined in the end used application. <br />6. Ground Screw size is No. 6 thread forming screw with cupped washer is provided for grounding. The maximum size ground <br />wire that can be used is 14AWG. The maximum size branch circuit that the units can be connected to is 15A unless a 16- <br />14AWG six inch pigtail lead supplied by sign company is connected to ground terminal and then spliced to 12AWG ground wire <br />of a 20 A branch circuit. <br />7. Cover Screw shall not be of a thread forming or self-tapping type. <br />8. To keep the enclosure from rotating, the Enclosure shall be secured by at least one mechanical fastener.
The URL can be used to link to this page
Your browser does not support the video tag.