Laserfiche WebLink
Exhibit A: Master Compliance Record (MCR) <br />PLEASE RECORD MARKING INFORMATION IDENTIFIED ON SIGN:Instructions: the manufacturer must complete this form for each sign or family of sign <br />manufactured. As an alternate, the manufactured may use their own document or form provided the <br />following content is available for review by the UL field representative curing UL factory <br />Inspection visits. Electronics records are acceptable. <br />Electrical Ratings <br />120 Volts 1.5 Amps <br />Frequency (HZ) <br />Date Code Listing mark serial # <br />07/22/13 N/A <br />The products identified below were reviewed for compliance with applicable requirement <br />current version of UL 48 Standard, UL Follow-up Inspedion Instructions, SAM, applicable, <br />bulletins, and times note below: <br />UL mark applied Applied <br />I Yes , O Ne " 541' O 6..'el,ORivul <br />Grounding Bonding StatementAccordance with <br />Article 600 NEC inctuded I Yes / O\JO <br />UL File #:Volume #: <br />Product type Identlfication: <br />(list model no,, pan no. customer name, etc ) <br />Unique Identification <br />(list date code, senal #, lot #, or other unique identifier) <br />Sign Construction type: <br />O Outdoor O Cabinet Sign <br />1 Indoor 0 Section (no. of sedions:_J <br />Date of Manufacture <br />BAG IN STYLE <br />Illumination Sourse: <br />Ofluorescent ONeon ILED <br />HID Incandescent <br />1. Please record information for critical components and material used in the sign construction <br />2. As an alternate, the manufacturer may choose to attach a parts list (hard copy or electrical )in <br />lieu of completing the following list. If parts list is attached, please check box here. <br />3. Critical components include the fallowing components: <br />ballasts, transtormers, power supplies <br />heat producing components, plastics, fiexible signs face materials, gaskets, boots. sleeving <br />lanip holders and electrodes, switches, AWM and wiring materials, etc. <br />all components shall be 1. listed, 2. recognized in sign components manual: 3. classified for use with sign <br />4. FUS procedure described, <br />Construction Review (see notes): <br />The sign(s) was evaluated using this <br />criteria and found to comply with UL 48 <br />requirements: <br />Performance Review (see notes): <br />The sign (s) was evaluation using the following criteria <br />and found to comply with requirements: <br />LED CHANNEL LETTERS <br />SIGN COMPONENTS / SPECS <br />>< LED LIGHT COMPANY NAME SS LIGHT SERIES WHITE <br />1. Frame and Enclosure <br />2. Ventilating Openings <br />3. Sign face / Panels <br />4. Resistance to Moisture / Drain Holes <br />5. Ground and Bonding <br />6. Electrical & Thermal spacings <br />7. Wire Routing & support <br />8. General workmanship <br />a. e.g. no metal shavings or sharp <br />edges, etc. <br />9. Correct Hardware <br />a. e.g. wire nuts, fasteners, <br />1. mechanical tests <br />2. Exclusion of water test <br />3. Strain relief test <br />4. Grounding Continuity <br />5. List other tests performed. <br />LED TRANSFORMER <br />X MODEL <br />DC VOLTAGE <br />RATED CURRENT <br />RATED RANGE <br />RATED POWER <br />CLASS 2 POWER <br />LED CABLES <br />UL#: E346996 <br />2 <br />FAHUA E <br />MODEL: HMA·100NU-RX 8 <br />12V <br />8A <br />I.SA <br />100 W / <br />12V/2 CIRCUIT <br />.E <br />SLOAN CABLE SLO- CABLE- M <br />fittings, gaskets, etc. <br />10. Electrical / Supply connections <br />a. Electrical Schematics <br />11. Installation instructions (provided with sign) <br />12. Correct Components <br />(complete Critical components list next page) <br />PLASTICS 3/16'-r. <br /> METALS .090 THICK Z <br />LEXAN NAME GE PLASTICS,150 THICKNESS <br />LEXAN MSG4101-4 <br />TRIMCAP 3/4'JEWEL TRIP CAP m2 <br />For construction Review and Performance Review: <br />All of the above criteria was met satisfactorily in compliance with UL 48 : I YES <br />if NO or N/A, describes specifies: <br />C]NO [ZIN/A <br />SCREWS SELF TAP /MACHINE <br />For any box checked 'No' above, what <br />containment action was taken ? <br />O Sign reworked and repaired <br />O Sign shipped but is not labeled w/ UL mark <br />O Sign scrapped other disposition : <br />If Sign was repaired, describe reqork actions below <br />Was sign re-inspected or retested and found to comply <br />with requiremetns? <br />U Yes INo IN/A <br />SWITCH <br />WIRE NUTS <br />POLYCARBONATE <br />WHITE UV <br />TUF GLASS <br />TOGGLE <br />UL LIST EC) ORANGE _ RED_ BLUE _ <br />SPARTECH PLASTICS <br />.150 THICKNESS <br />MSG45-4 <br />SPARTECH PLASTICS TUF GLASS <br />-177 THICKNESS <br />MTG17-42 <br />Notel · If results do not comply products must be re-worked and bought and back into compliance or not with UL Mad<. <br />If re-worked, products must be re-ininspected or retested to verify compliance. <br />Note 2: Record O4etails ot results if no-contormances are identified, Including disposition and rework details. Recorded <br />Corrective actions taken to bring the product into conforniance. <br />By Con,wo#ng 0)0 intomm#an bdow, ; contimi chal thi p,odusts #*zodabovo woriman,flac:un,d, in,poctod, fostod Ind doto,minid to be b oompling• with UL ioquwornonti, <br />Completed by Manufacturer SIGNCOMM CHRIS LEE 07-22-13 <br />Technical representative Company Name Print Name -Date. ,