Laserfiche WebLink
June 19, 2013 SIGN COMPONENTS MANUAL (SAM) 74 <br />4. These products are not required to be enclosed or protected from the weather in the end product. <br />5. These products may be secured in place in the end product by any means available. <br />KEYSTONE TECHNOLOGIES LLC E356111 <br />PO BOX 246 <br />AMBLER, PA 19002 <br />Class 2 LED Modules, Models KTLD-80-1-24V, KTLD-60-1-12V, KTLD-60-1-24V, KTLD-60-1-24\ASC, KTLD-60-UV-24V, KTLD- <br />60-UV-24V-SC, KTLD-60-UV-24V-DIW, KTLD-60-UV-1214V, KTLD-60-UV-1214V-SC. <br />1. These LED drivers have been evaluated using resistive load resulting in the electrical input and output noted on page 1. <br />2. These LED drivers are provided with Class 2 output. <br />3. These LED drivers are intended to be operated jn_ a maximum ambient (Ta) noted as below: <br />Model Ta (°C) <br />TLD-80-1-24V 40 <br />KTLD-60-1-12\/ 40 <br />:KTLD-60-1-24V 40 <br />'KTLD-60-1-24V-SC 40 <br />®TLD-60-UV-24V 40 <br />f KTLD-60-UV-24\ASC 40 <br />kTLD-60-UV-24\ADIW 52 <br />1<TLD-60-UV-1214V 40 <br />1<TLD-60-UV-1214\ASC 40 <br />4. These LED drivers are intended for use in dry and damp locations except that models KTLD-60-UV-1214V and KTLD-60-UV- <br />1214\ASC are suitable for dry location only. <br />5. These LED drivers are provided with 18 AWG AWM input and output leads. The suitability of the wiring and the need for a <br />suitable enclosure shall be considered in the end product. <br />6. These LED drivers are intended to be operated on a maximum 20 A branch circuit. <br />7. The need of the grounding means shall be determined in the end product. <br />8. These LED drivers shall be enclosed within a suitable end product enclosure. <br />9. For model KTLD-60-UV-24\ADIW, the conduit knockout test was not conducted. The suitability is to be determined in end <br />product. <br />10. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />11. In the end product, LED Drivers shall be located not less than 1 inch (25.4 mm) apart when arranged end-to-end, and not less <br />than 4 inches (102 mm) apart when arranged otherwise. <br />KING BILLION (ASIA) LTD E362583 <br />UNIT A 3/F CHEONG SUN TOWER <br />116-118 WING LOK ST <br />SHEUNG WAN, HONG KONG <br />Class 2 LED Modules, designated as XXXX YYYYD/M series, where XXXX and YYYY may be combinations of any numbers. <br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. <br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy <br />limited circuits. <br />3. When these units are connected to a Class 2 supply circuit, they are not to draw a total wattage of greater than the secondary <br />or output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations. <br />5. These products are not required to be enclosed or protected from the weather in the end product. <br />6. These products may be secured in place in the end product by any means available. <br />KOLEDO INTERNATIONAL BV <br />EKKERSRIJT 7051 <br />E346915 <br />5692 HB SON EN BREUGEL, THE NETHERLANDS <br />LED Light Strings, LED Strings Series 12NC - "Affinium High Powered LED Light Strings", Part Nos. 9290 004 61903, 9290 004 <br />62103, 9290 004 62203,9290 004 62303,9290 004 62403. <br />1. These components are only suitable for connection to a UL Listed or R/C (UYMR2), Component - Sign Accessory Class 2 <br />power source, rated 30V DC or less. <br />2. These components have not been evaluated for use and connection to a power source supply with outputs parameters <br />exceeding the limitations for a Class 2 circuit. <br />3. Class 2 LED Strings when connected to a Class 2 source, are not to draw a total current or wattage of greater than the <br />secondary or output rating of the Class 2 circuit. <br />4. These components are suitable for use in Dry, Damp, and wet locations and are not and are not required to be enclosed or <br />protected from the weather in the end product when connected to Class 2 source of supply with 30 V DC or less maximum <br />voltage. <br />5. These products described in this section may be cut into segments per manufacture's installation instructions. <br />LED Posterbox modules, Models LPM8W6300K325mm (12.8")300, LPM13W6300K565mm (22.2")300, LPM8W6300K565mm <br />(22,2")300, LPM6W6300K325mm (12.8")300, LPM8W4000K325mm(12.8")330, LPM13W4000K565mm(22.2")300 or Alternate <br />Catalog Numbers: 9290 004 834,9290 004 835,9290 004 836,9290 004 837,9290 006 007,9290 006 008. Models LPM6300K <br />371 mm 4leds 400, LPM6300K 565mm 6leds 400, LPM2700K 371 mm 4leds 400, LPM2700K 565mm 6leds 400, LPM4000K