My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1202 S Karen Ave - Plan
PBA
>
Building
>
ProjectDox
>
K
>
Karen Ave
>
1202 S Karen Ave
>
1202 S Karen Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 8:01:20 AM
Creation date
5/30/2025 8:00:27 AM
Metadata
Fields
Template:
Plan
Permit Number
20176280
101110579
Full Address
1202 S Karen Ave
Document Relationships
101110579 - Permit
(Permit - Plan)
Path:
\Building\Permits\K\Karen Ave\1202 S Karen Ave
20176280 - Permit
(Permit - Plan)
Path:
\Building\Permits\K\Karen Ave\1202 S Karen Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HOMEOWNER: DENNIS HOANG <br />PH: 714.588.4468 <br />ADDRESS: 1202 S. KAREN AVENUE <br />SANTA ANA, CA 92704 <br />DATE: 5/2/22DATE: 5/2/22 <br />(&262/$5 86$ <br />(/(&75,&$///& <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />6&23(2):25. <br />INSTALL (17) SUNPOWER SPR-X22-360-E-AC SOLAR <br />ELECTRIC MODULES ON THE EXISTING 1ST STORY <br />COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING <br />HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND <br />GROUNDING. INSTALL (1) LOAD CENTER, (1) AC DISCONNECT, <br />AND INSTALL OCPD IN MAIN SERVICE PANEL. <br />9,&,1,7<0$3 <br />HOANG <br />RESIDENCE <br />6+((7,1'(; <br />SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK <br />SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL <br />SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />SHEET 4 CALCULATIONS, SIGNS <br />ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />STRUCTURAL REPORT <br />NTS <br />6+((7 <br />127,&( <br />$1<&+$1*(67225 86(62)7+(6('2&80(176'5$:,1*6:,7+2877+( <br />:5,77(1&216(172)-(11,)(5 .(00(25 6&277+$55,6$5(675,&7/<352+,%,7(' <br />2) <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />(17) SUNPOWER SPR-X22-360-E-AC <br />AC MODULES <br />PEAK POWER = 360 W <br />MAX OUTPUT CURRENT = 1.31 A <br />MAX OCPD = 20 A <br />MAX NUMBER IN SERIES = 12 <br />TEMP. COEFF. OF POWER = -0.29%/°C <br />DIMENSIONS = 61.3" X 41.2" X 1.8" <br />WEIGHT = 42.9 LBS <br />*(1(5$/127(6 <br />1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />3+27292/7$,&62/$5 352-(&7,1)250$7,21 <br />SYSTEM SIZE: 6.120 kW (DC) <br />MODULES: <br />ARRAY:INSTALLED WEIGHT = 2.9 PSF <br />ROOF COVERAGE = 300 SF, <br />LESS THAN 50% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: SUNPOWER INVISIMOUNT RAIL <br />UNIRAC STANDOFF W/ <br />CHEM CURB ATTACHMENTS <br />5 16" STAINLESS STEEL LAG BOLTS @ <br />72" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 1 STORY, ROLLED COMPOSITION <br />2 X 6 RAFTERS @ 24" OC <br />Bldg #101110579 <br />Elect #20176280 <br />Permits issued on 6/29/22 <br />1202 S Karen Ave <br />06/29/22
The URL can be used to link to this page
Your browser does not support the video tag.