HOMEOWNER: DENNIS HOANG <br />PH: 714.588.4468 <br />ADDRESS: 1202 S. KAREN AVENUE <br />SANTA ANA, CA 92704 <br />DATE: 5/2/22DATE: 5/2/22 <br />(&262/$5 86$ <br />(/(&75,&$///& <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />6&23(2):25. <br />INSTALL (17) SUNPOWER SPR-X22-360-E-AC SOLAR <br />ELECTRIC MODULES ON THE EXISTING 1ST STORY <br />COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING <br />HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND <br />GROUNDING. INSTALL (1) LOAD CENTER, (1) AC DISCONNECT, <br />AND INSTALL OCPD IN MAIN SERVICE PANEL. <br />(/(&75,&$//,1(',$*5$0 <br />6+((7 <br />127,&( <br />$1<&+$1*(67225 86(62)7+(6('2&80(176'5$:,1*6:,7+2877+( <br />:5,77(1&216(172)-(11,)(5 .(00(25 6&277+$55,6$5(675,&7/<352+,%,7(' <br />2) <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />MAIN SERVICE INFO: <br />100 A, 120/240 VAC, <br />1Ø, 3-WIRE <br />METER #222013-843290 <br />30A <br />100A <br />EXISTING BUILDING <br />GROUNDING <br />ELECTRODE SYSTEM <br />M <br />EXISTING SERVICE PANEL: <br />125 A BUS RATED, 240 VAC, 1ØSOURCE CIRCUIT #1: <br />9 MODULES, 240 VAC <br />L1 <br />L2 <br />L1 <br />L2 <br />L1 <br />L2 <br />SOURCE CIRCUIT #2: <br />8 MODULES, 240 VAC <br />NEMA 3R, 240 VAC <br />JUNCTION BOX <br />L1 <br />L2 <br />L1 <br />L2 <br />L1 <br />L2 <br />+ <br />- <br />+ <br />- <br />+ <br />- <br />+ <br />- <br />+ <br />- <br />+ <br />- <br />USE SUNPOWER INTEGRATED GROUNDING TO <br />GROUND ALL MODULES, JUNCTION BOXES AND <br />ANY OTHER METAL PARTS AND GROUND LUGS <br />WITH #6 AWG SOLID COPPER WHERE NEEDED <br />12 AWG (TYP) <br />SUNPOWER <br />SPR-X22-360-E-AC <br />SUNPOWER <br />SPR-X22-360-E-AC <br />SUNPOWER <br />SPR-X22-360-E-AC <br />SUNPOWER <br />SPR-X22-360-E-AC <br />SUNPOWER <br />SPR-X22-360-E-AC <br />SUNPOWER <br />SPR-X22-360-E-AC <br />(4) 10 AWG THWN-2 & <br />(1) 10 AWG GROUND <br />IN 3 4" EMT CONDUIT <br />20A <br />20A <br />LOAD CENTER <br />125 A BUS RATED <br />240 VAC, 1Ø <br />(3) 10 AWG THWN-2 & <br />(1) 10 AWG GROUND <br />IN 3 4" EMT CONDUIT <br />QUAD BREAKERS TO <br />MAKE SPACE FOR <br />SOLAR BREAKER <br />20A <br />TO <br /> <br />M <br />O <br />N <br />I <br />T <br />O <br />R <br />I <br />N <br />G <br />G <br />L1 <br />L2 <br />60 A, 240 VAC, 1Ø <br />AC DISCONNECT <br />LOCKABLE, VISIBLE <br />KNIFE-BLADE TYPE <br />(3) 10 AWG THWN-2 & <br />(1) 10 AWG GROUND <br />IN 3 4" EMT CONDUIT <br />1202 S Karen Ave <br />06/29/22