Laserfiche WebLink
M <br />120/240 VAC <br />SINGLE PHASE SERVICE <br />(E)GROUND <br />EXISTING 200A <br />MAIN BREAKER <br />(END FED) <br />EXISTING 200A <br />METER/MAIN PANEL <br />20A PV BREAKER <br />INSTALLED AT OPPOSITE END OF <br />BUSBAR FROM MAIN BREAKER <br />20A-2P <br />200A <br />NO CENTER-FED <br />MAIN BREAKER <br />C <br />J-BOX <br />NEMA3R <br />A B <br />+- <br />DC <br />DC <br />INTEGRATED <br />DC DISCONNECT & AFCI <br />AC <br />DC <br />SOLAREDGE TECHNOLOGIES <br />SE3800H-US (240V) <br />HD WAVE INVERTER STRING 1: <br />(12)MSOLAR <br /> (HC 144BB-440W) 440 WATT <br />SOLAR MODULES PAIRED WITH <br />(12)P505 OPTIMIZERS IN <br />(1)SERIES STRING <br />SOLAREDGE <br />P505 OPTIMIZER <br />E-1.0REV: A <br />GARDOT, MARNI <br />1128 W RIVIERA DR <br />SANTA ANA, CA 92706 <br />APN # 5643-820-900 TEL #: ---- <br />CLIENT: <br />ELECTRICAL <br />1611 POMONA RD.,STE# 206 <br />CORONA, CA 92878 <br />CSLB # 1043108 <br />PHONE 951.298.9007 <br />CONTRACTOR: <br />ELECTRICAL <br />IRONRIDGE INTEGRATED GROUNDING & LAY-IN LUGS ARE UL2703 LISTEDGROUNDING DETAIL <br />scale: NTS <br />RAILS MODULES <br />IRONRIDGE RAIL <br />PV MODULE FRAME <br />IRONRIDGE GROUNDING PIERCES <br />THROUGH ANODIZED COATINGS <br />OF MODULE FRAMES AND RAILS <br />IRONRIDGE UNIVERSAL <br />FASTENING OBJECT <br />LAY-IN LUG TERMINAL <br />AL/CU DUAL RATED <br />(TIN PLATED CU) <br />SS SET SCREW INCLUDED <br />IRONRIDGE RAIL <br />#10-24 SS LOCK NUT <br />6 AWG BARE CU WIRE <br />TE#10-24 X 3/4" SS HCS BOLT <br />#10 SS EXTERNAL TOOTH <br />LOCK (STAR) WASHER <br />∆ <br />TAG CONDUCTOR CONDUCTOR <br />SIZE <br />NUMBER OF <br />CONDUCTORS <br />CONDUIT/CABLE <br />TYPE CONDUIT SIZE <br />A PV-WIRE 10 AWG 2 <br />FREE AIR N/A <br />EGC/GEC: BARE COPPER 6 AWG 1 <br />B THHN/THWN-2 10 AWG 2 <br />EMT 3/4" <br />EGC/GEC: THHN/THWN-2 8 AWG 1 <br />C LINE:THHN/THWN-2 10 AWG 2 <br />EMT 3/4"NEUTRAL: THHN/THWN-2 10 AWG 1 <br />EGC/GEC: THHN/THWN-2 8 AWG 1 <br />SOLAREDGE NOTES: <br />1. STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND MAINTAINED AT NOMINAL 380 VDC. <br />2. STRING VOLTAGE IS LIMITED BY INVERTER TO A MAXIMUM OF 480VDC <br />3. SOLAREDGE DC/DC OPTIMIZERS ARE ALL RUN IN SERIES PER STRING (FIXED SOURCE CIRCUIT VOLTAGE - DC/DC CONVERTERS) <br />4. STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS LIMITED TO 15ADC MAX (PER STRING). <br />5. INTEGRATED SOLAREDGE DC SWITCH DISCONNECTS BOTH POSITIVE AND NEGATIVE CONDUCTORS AS REQUIRED. <br />6. SOLAREDGE INVERTERS ARE ALL RAPID SHUTDOWN READY PER CEC 690.12 <br />7. SOLAREDGE INVERTER IS SMART INVERTER COMPLIANT PER CALIFORNIA RULE 21. <br />SYSTEM NOTES: <br />1. PV SYSTEM IS UNGROUNDED <br />2. MODULES ARE BONDED TO RAIL USING IRONRIDGE INTEGRATED GROUNDING. <br />3. RAILS ARE BONDED USING UL 2703 RATED LAY-IN LUGS <br />4. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA IRREVERSIBLE CRIMP; GEC TO <br />BE CONTINUOUS PER CEC 250.64(C) <br />3/7/22 <br />1128 W Riviera Dr <br />05/31/22