ESR-1308 | Most Widely Accepted and Trusted Page 2 of 21
<br />3.1.2 EAC Main Runners, Low Voltage, Nonfire-
<br />resistance-rated: Main runners for use with low voltage
<br />powered lighting systems include the following: EAC
<br />Prelude Main Runners: DC730112, DC730110, DC730108,
<br />and DC730106; non-powered 730106; EAC Suprafine Main
<br />Runners: DC750112, DC750110, DC750108, and
<br />DC750106; the non-powered 750106; EAC Silhouette Main
<br />Runners: DC760112, DC760110, DC760108, and
<br />DC760106; and the non-powered 760106. The EAC
<br />Prelude, EAC Silhouette, and EAC Suprafine are classified
<br />as heavy-duty in accordance with ASTM C635. See Table 2
<br />for the listed runners, and Figure 1 for a profile of these
<br />runners.
<br />The EAC main runners are cold-formed from ASTM A568
<br />steel. The runners have a hot-dipped galvanized coating
<br />and a factory-installed, polyester-painted steel cap along the
<br />entire length of the bottom flange. The EAC Silhouette
<br />series has a painted coating in addition to the hot-dipped
<br />galvanized coating and have no cap on the bottom flange.
<br />The EAC Prelude, EAC Silhouette, and EAC Suprafine
<br />main runners have a snap-on upper polymerprofile that
<br />supports two tin-plated copper conducted strips that serve
<br />to carry the low voltage current. The EAC Silhouette main
<br />runners also have a lower conductive snap-on polymer
<br />conductive strip in the lower box profile in addition to the
<br />upper conductive snap-on polymer profile. The snap-on
<br />polymer has a flame-spread index of 25 or less and a
<br />smoke-developed index of 50 or less, when tested in
<br />accordance with ASTM E84.
<br />The EAC main runners are used in conjunction with the
<br />XL 7300 (Prelude), XL 7500 (Suprafine) and XL 7600
<br />(Silhouette) cross runners listed in Table 3 of this report.
<br />3.1.3 Main Runners, Gravity Loaded, and Nonfire-
<br />resistance-rated: Main runners for use to support gravity
<br />loads only in non-fire-resistance-rated ceiling assemblies
<br />include 730145 series. The suspended ceiling framing
<br />system must be installed in accordance with the IBC Section
<br />808 for ceiling systems up to 4 psf (19.5 kg/m2) of uniform
<br />gravity load. The 730145 main runners are cold-formed from
<br />ASTM A568 steel. The runners have a hot-dipped
<br />galvanized coating and a factory-installed, polyester-
<br />painted steel cap along the entire length of the bottom
<br />flange. The 730145 main runners are used in conjunction
<br />with XL7325 and XL 7345 cross runners listed in Table 3 of
<br />this report. Profiles of the runners are shown in Figure 1.
<br />3.1.4 Cross Runners, Nonfire-resistance-rated: Cross
<br />runners for use in nonfire-resistance-rated ceiling
<br />assemblies are the XL6100 series (Interlude), XL6500
<br />series (Sonata), XL7100 series (Prelude), XLAL7200 series
<br />(Aluminum Prelude), XLSS7200 series (Stainless Prelude),
<br />XL7300 series (Prelude), XL7500 series (Suprafine),
<br />XL7600 series (Silhouette), XL76008 series (Silhouette),
<br />EA7900 series (Aluminum 15/16 inch Clean Room), EA7903
<br />series (Aluminum 11/2 inch Clean Room), and ES7900
<br />series (Steel 15/16 inch Clean Room).
<br />The XL 6100 series, XL6500 series, XL7100 series,
<br />XL7300 series, XL7500 series, XL7600 series and XL76008
<br />series ES7900 series cross runners are cold-formed from
<br />ASTM A568 steel. The cross runners have a hot-dipped
<br />galvanized coating and a factory-installed polyester-painted
<br />steel cap or aluminum cap along the entire length of the
<br />bottom flange. The XL 6100 XL6500, ES7900 and XL7600
<br />and XL 76008 series have a baked polyester painted
<br />coating in addition to the hot-dipped galvanized coating, and
<br />have no capping on the lower flange. The XLAL 7200,
<br />EA7900 and EA7903 series runners are cold-formed from
<br />3003-H14 aluminum and have a baked polyester painted
<br />coating. The XL6500 series, ES7900 series, EA7900 series
<br />and EA7903 series runners have a polyurethane-filled upper
<br />bulb in addition to a polyurethane-coated lower flange. The
<br />XLSS 7200 runners are cold-formed from 300 series
<br />stainless steel complying with ASTM A480. Table 3
<br />specifies dimensions, lengths, and allowable transverse
<br />loads.
<br />3.1.5 Main Runners, Fire-resistance-rated: Main
<br />runners for use in fire-resistance-rated ceiling assemblies
<br />are the HD 8201, 8300, 8301, 8500 and 8501 runners listed
<br />in Table 2. The 8300 and 8500 runners are classified
<br />structurally as intermediate-duty in accordance with ASTM
<br />C635; Models 8301, 8501, and HD 8201 main runners are
<br />classified as heavy-duty. Profiles of runners are shown in
<br />Figure 1.
<br />All members have an inverted T-shape. Members are
<br />cold-formed from ASTM A568 steel with a hot-dipped
<br />galvanized coating.
<br />Models 8300, HD 8201 and 8301 have a factory-installed
<br />steel cap along the entire length of the bottom flange. The
<br />HD 8201 member has a hot-dipped galvanized coating and
<br />a bottom flange cap made from either 3003-H16 or 3105-
<br />H16 aluminum. Table 2 specifies dimensions, lengths and
<br />allowable transverse loads.
<br />3.1.6 Cross Runners, Fire-resistance-rated: Cross
<br />runners for use in fire-resistance-rated ceiling assemblies
<br />are the XL 8200 series (Prelude Plus Fire Guard), XL8300
<br />series (Prelude Fire Guard), and XL 8500 (Prelude
<br />Suprafine Fire Guard) series runners listed in Table 3.
<br />Profiles of runners are shown in Figure 1. Members are
<br />cold-formed from ASTM A568 steel with a hot-dipped
<br />galvanized coating. The XL 8300 and XL 8500 series have
<br />a factory-installed steel cap along the entire length of the
<br />bottom flange. The XL 8200 series members have a
<br />hot-dipped galvanized coating and a bottom flange cap
<br />made from either 3003-H16 or 3105-H-16 aluminum. Table
<br />3 specifies dimensions, lengths and allowable transverse
<br />loads.
<br />3.1.7 Cross Runners, Gravity Loaded, and Nonfire-
<br />resistance-rated: Cross runners for use to support gravity
<br />loads only and in non-fire-resistance rated ceiling
<br />assemblies are the XL 7325 and XL 7345 series runners
<br />listed in Table 3. The suspended ceiling framing system
<br />must be installed in accordance with the 2015, 2012, and
<br />2009 IBC Section 808 for ceiling systems up to 4 psf
<br />(19.5 kg/m2) of uniform gravity load. Profiles of the runners
<br />are shown in Figure 1. Members are cold-formed from
<br />ASTM A568 steel with a hot-dipped galvanized coating and
<br />a factory-installed, polyester-painted steel cap along the
<br />entire length of the bottom flange. Table 3 specifies
<br />dimensions, lengths, and allowable transverse loads.
<br />3.1.8 Materials: Steel runners are cold formed from ASTM
<br />A653 CS Type B steel and have a hot-dipped galvanized
<br />minimum protective zinc coating of G30, G60, or G90. The
<br />steel runners have a carbon steel composition that conforms
<br />to ASTM A568 and a zinc protective coating that conforms
<br />to ASTM A653. Aluminum runners are cold-formed from
<br />3003-H14 and 3105-H24 aluminum, and the stainless steel
<br />runners are cold formed from 300 series stainless steel.
<br />3.2 Hanger Wire:
<br />Hanger wire for suspended ceilings, framing members, and
<br />any fixtures must comply with Section 13.5.6 of ASCE 7 and
<br />IBC Section 2506.2.1.
<br />3.3 BERC Clip:
<br />The BERC (Beam End Retaining Clip) System is illustrated
<br />in Figure 3. The BERC clip is used to connect main and
<br />2130 E 17th St -
<br />10111279406/07/23
|