My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2130 E 17th St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Seventeenth St
>
2130 E Seventeenth St Unit# A
>
2130 E 17th St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:40:33 PM
Creation date
5/30/2025 8:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
101112794
Full Address
2130 E Seventeenth St Unit# A
Document Relationships
101112794 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Seventeenth St\2130 E Seventeenth St Unit# A
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ESR-1308 | Most Widely Accepted and Trusted Page 18 of 21 <br />10. Hanger Wire: Number 12 SWG galvanized wire must be twist-tied to steel joists or cold-rolled steel channels. When the ceiling consists <br />of nominal 24-by-24-inch panels or 24-by-48-inch panels, hanger wires must be spaced a maximum of 48 inches on center on main <br />runners adjacent to cross tee intersections. Hanger wires must occur at all four corners of light fixtures, at midspan of cross tees adjacent <br />to 4-foot light fixtures and air duct outlets, and adjacent to each main runner splice. When the ceiling consists of nominal 20-by-60-inch <br />panels, hanger wires must be spaced 40 inches on center along main runners, and one wire must occur at each corner of light fixtures, at <br />midspan of all cross tees, and adjacent to each main runner splice. <br />11. Air Duct: Minimum 0.019-inch-thick (26 gage) galvanized steel. Total area of duct openings must not exceed 576 square inches per <br />each 100 square feet of ceiling area. Area of individual duct openings must not exceed 576 square inches. Maximum opening dimension <br />is 18 inches. Inside and outside faces of duct throat must be protected with 1/16-inch-thick ceramic fiber paper, laminated to the metal. <br />Maximum dimension of opening is 30 inches. Duct supported by 11/2-inch-deep, minimum 0.053-inch-thick (16 gage) cold-rolled steel <br />channels spaced not over 48 inches on center, suspended by No. 12 SWG galvanized steel wire. <br />12. Damper: Minimum 0.056-inch-thick (16 gage) galvanized steel, sized to overlap duct opening a minimum of 2 inches. Protected on both <br />sides with 1/16-inch-thick ceramic fiber paper, laminated to the metal, and held open with a fusible link. <br />13. Fixtures, Recessed Light: Fluorescent-lamp-type steel housing, nominally 2 by 4 feet or 20 by 60 inches in size. Fixtures must be <br />spaced so their total area does not exceed 24 square feet per each 100 square feet of ceiling area. When 20-by-60 inch fixtures must be <br />used, fixture stabilizers formed from No. 16 gage steel channels, must be used in addition to the hanger wires at midspan of the cross <br />tees. Fixture must be wired in conformance with the National Electrical Code. Fixture and ballasts must be considered for ambient <br />temperature conditions before installation. <br />14. Fixture Protection—Acoustical Material—Armstrong World Industries, Inc.: Type 5/8-inch P (S) or 5/8-inch PC (S) is cut to form a <br />five-sided enclosure, trapezoidal in cross section, approximately 1/2 inch longer and wider, and 5/8 inch higher, than the light fixture <br />housing. For 2-by-4-foot fixtures, the protection consists of a 233/ 4-by-473/4-inch top piece, two 5 7/8-by-473/4-inch side pieces, and two <br />41/2-by-233/4-inch end pieces. For 20-by-60-inch fixtures, the protection consists of a nominal 20-by-60-inch top piece, two nominal 6-by- <br />60-inch side pieces, and two nominal 41/2-by-20-inch end pieces. The top edge of each fixture protection side piece may be provided with <br />a 1-inch-deep-by-maximum-20-inch-long notch near its midpoint. The side and top pieces must be laid in place and the end pieces must <br />be held in place with three 8d nails spaced 8 inches on center. (S) - Surface perforations. <br />15. Steel Framing Members—Armstrong World Industries, Inc.: Type 8500 systems with a 15/16-inch-wide flange grid must be used. Main <br />runners, nominally 12 feet long, must be spaced 4 feet on center. Cross tees, nominally 4 feet long, must be installed perpendicular to <br />main runners and spaced 2 feet on center. Cross tees, nominally 2 feet long, must be installed perpendicular to 4-foot cross tees and <br />spaced 4 feet on center. Grid modules containing light fixtures must employ a fixture-centering clip at each corner. The No. 24 gage <br />electrogalvanized steel clip is nested on the flange of the intersecting grid tees, has two 1 7/16-inch-long legs with their sides perpendicular <br />to each other, and has a U-shaped return at the top of each leg for engaging over the bulb of the intersecting grid tees. <br />16. Acoustical Material: Nominal 24-by-24-inch or -48-inch lay-in panels. Border panels must be supported at walls by minimum 0.016-inch- <br />thick (26 gage) painted steel angles with 7/ 8-inch legs; or, minimum 0.016-inch-thick (26 gage) painted steel channels, 1 1/8 inches deep <br />with 7/8-inch flanges. <br />17. Hold-down Clips: (Not shown) Number 24 MSG spring steel, placed over cross tees at 2 feet on center. <br />FIGURE 6—8500 SERIES ONE-HOUR FIRE-RESISTANCE-RATED ASSEMBLY (Continued) <br />1. Beam: <br />2. Normal-weight Concrete <br />3. Welded Wire Fabric <br />4. Steel Form Units <br />5. Steel Joists <br />6. Bridging <br />7. Hanger Wire <br />8. Air Duct <br />9. Damper: No. 16 MSG minimum galvanized steel, sized to overlap duct opening 2 inches, minimum. Protected on both sides with <br />1/16-inch-thick ceramic fiber paper laminated to the metal with adhesive and held open with a listed fusible link. <br />10. Fixtures, Recessed Light <br />11. Fixture Protection—Batts and Blankets <br />12. Steel Framing Members—Worthington Armstrong Venture <br />13. Acoustical Material <br />14. Hold-down Clips (Not illustrated) <br />For SI: 1 inch = 25.4 mm. <br />FIGURE 7—TWO-HOUR FIRE-RESISTANCE-RATED FLOOR-CEILING ASSEMBLY (REFER TO SECTION 4.6 OF THIS REPORT) <br />2130 E 17th St - <br />10111279406/07/23
The URL can be used to link to this page
Your browser does not support the video tag.