Laserfiche WebLink
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed <br />as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as <br />to any finding or other matter in this report, or as to any product covered by the report. <br />Copyright © 2022 ICC Evaluation Service, LLC. All rights reserved. Page 19 of 21 <br />ICC-ES Evaluation Report ESR-1308 LABC Supplement <br />Reissued December 2022 <br />This report is subject to renewal December 2023. <br />www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® <br />DIVISION: 09 00 00—FINISHES <br />Section: 09 22 26—Suspension Systems <br />Section: 09 53 00—Acoustical Ceiling Suspension Assemblies <br />REPORT HOLDER: <br />WORTHINGTON ARMSTRONG VENTURE (WAVE) <br />EVALUATION SUBJECT: <br />FIRE- AND NONFIRE-RESISTANCE-RATED SUSPENDED CEILING FRAMING SYSTEMS <br />1.0 REPORT PURPOSE AND SCOPE <br />Purpose: <br />The purpose of this evaluation report supplement is to indicate that Fire- and Nonfire-Resistance-Rated Suspended Ceiling <br />Framing Systems, described in ICC-ES evaluation report ESR-1308, have also been evaluated for compliance with the code <br />noted below as adopted by the Los Angeles Department of Building and Safety (LADBS). <br />Applicable code edition: <br /> 2020 City of Los Angeles Building Code (LABC) <br />2.0 CONCLUSIONS <br />The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Framing Systems described in Sections 2.0 through 7.0 of the <br />evaluation report ESR-1308, comply with the LABC Chapters 8, 16 and 25, and the LARC, and are subject to the conditions <br />of use described in this supplement. <br />3.0 CONDITIONS OF USE <br />The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Framing Systems described in this evaluation report supplement <br />must comply with all of the following conditions: <br />• All applicable sections in the evaluation report ESR-1308. <br />• The design, installation, conditions of use and identification of the Fire- and Nonfire-Resistance-Rated Suspended Ceiling <br />Framing Systems are in accordance with the 2018 International Building Code ® (IBC) provisions noted in the evaluation <br />report ESR-1308. <br />• The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as <br />applicable. <br />• Main runners shall be identified by indentation or by nontransferable decal with letter not less than 1/4–inch high and shall <br />include manufacturer’s name and runner designation. <br />This supplement expires concurrently with the evaluation report, reissued December 2022. <br />2130 E 17th St - <br />10111279406/07/23