Laserfiche WebLink
JOB NO.: U1932.3053.211 <br />SUBJECT: SEISMIC LOADS <br />PROJECT: Gomez, Guillermina Residence <br />CHECK INCREASE IN OVERALL SEISMIC LOADS <br />10.0 psf <br />500 ft2 <br />10 psf <br />8 ft <br />32 ft <br />6.3 k <br />2.8 psf <br />226 ft2 <br />45% <br />6.9 k <br />9.9% <br />Proposed Seismic Weight <br />Roof Area <br />Wall Dead Load <br />Wall Height <br />Roof Perimeter <br />Estimated Roof Dead Load <br />Solar Dead Load <br />Existing Seismic Weight <br />Solar Area <br />% Roof Covered <br />The installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 9.9%. <br />Because the increase is less than 10%, this addition meets the requirements of the exception in Section 503.4 of <br />the 2019 CEBC. Thus the existing structure is permitted to remain unaltered. <br />Addt'l Seismic Weight <br />2235 S. Park Drive <br />03/14/22