Laserfiche WebLink
JOB NO.: U1932.3053.211 <br />SUBJECT: WIND PRESSURE <br />PROJECT: Gomez, Guillermina Residence <br />Label: Note: Calculations per ASCE 7-16 <br />SITE-SPECIFIC WIND PARAMETERS: <br />Basic Wind Speed [mph]: 95 Notes: <br />Exposure Category: C <br />Risk Category: II <br />Importance Factor, I: <br />ADDITIONAL INPUT & CALCULATIONS: <br />Height of Roof, h [ft]:15 (Approximate) <br />Comp/Cladding Location:(GCrn)nom, w=9.46° <br />Enclosure Classification: <br />Zone 1 (GCrn)nom:0.92 Zone 1 γ a:0.78 <br />Zone 2 (GCrn)nom:1.23 Zone 2 γa:0.78 <br />Zone 3 (GCrn)nom: 1.45 Zone 3 γa:0.78 <br />γa:0.40 <br />α: 9.5 Table 26.11-1 <br />zg [ft]: 900 Table 26.11-1 <br />Kh: 0.85 Table 26.10-1 <br />Ke: 1.00 Table 26.9-1 <br />Kzt: 1 Equation 26.8-1 <br />Kd: 0.85 Table 26.6-1 <br />Velocity Pressure, qh [psf]: 16.6 Equation 26.10-1 <br />γE: 1.50 Section 29.4.3 <br />γC: 0.94 Section 29.4.3 <br />γP: 1.20 Section 29.4.3 <br />p = q h (GC p )(γE )(γa ) <br />p = q h (GC rn ), (GC rn ) = (γ p )(γc )(γ E )(GC rn ) nom <br />Zone 1, p [psf]: 25.7 psf (1.0 W) <br />Zone 2, p [psf]: 34.5 psf (1.0 W) <br />Zone 3, p [psf]: 40.7 psf (1.0 W) <br />(2h = 30 ft) <br />Fig. <br />29.4-8 <br />WIND PRESSURES: Equation 29.4-5 <br />Solar Panel Array <br />Enclosed Buildings <br />Figure 29.4-7 <br />(negative coeff.) <br />Components and Cladding Wind Calculations <br />2235 S. Park Drive <br />03/14/22