My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2329 S Park Drive - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Park Dr
>
2329 S Park Dr
>
2329 S Park Drive - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:41:11 PM
Creation date
5/30/2025 8:00:53 AM
Metadata
Fields
Template:
Plan
Permit Number
20176224
101110490
Full Address
2329 S Park Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
· ALL GROUNDING PER CEC 250 & 690 <br />· THE DE-RATE FACTOR FOR CONDUCTORS <br />IN RACEWAY THRU AN ATTIC PER [NEC <br />310.15(2)(B)], THE LOCATION OF THE DC <br />RACEWAYS BENEATH THE ROOF, TO NOT BE <br />CLOSER THAN, & RUN PERPENDICULAR TO, <br />10" OF THE ROOF DECK AS REQUIRED BY, <br />PROVIDE A VISUAL BREAK UTILITY <br />DISCONNECT AT THE SERVICE METER <br />LOCATION <br />· THE PHOTOVOLTAIC INSTALLATION MEETS <br />RPU INTERCONNECT STANDARDS THRU THE <br />INSTALLATION OF A UTILITY DISCONNECT W/ <br />VISUAL BREAK BLADES, IN ADDITION THE <br />INVERTER MANUFACTURE MEETS ALL [UL <br />1741] ANTI ISLANDING CRITERIA. <br />· WORKING CLEARANCES AROUND THE <br />EXISTING ELECTRICAL EQUIPMENT, AS WELL <br />AS, THE NEW ELECTRICAL EQUIPMENT WILL <br />BE MAINTAINED IN ACCORDANCE <br />· SPACING MUST BE MAINTAINED BETWEEN <br />ANY PLUMBING SEWER VENTS EXTENDING <br />THROUGH THE ROOF & THE UNDERSIDE OF <br />THE PHOTOVOLTAIC PANELS MAINTAIN 12” <br />MINIMUM HORIZONTALLY THE <br />PHOTOVOLTAIC INVERTER WILL BE LISTED AS <br />[UL 1741] COMPLIANT <br />· ALL METALLIC RACEWAYS & EQUIPMENT <br />SHALL BE BONDED & ELECTRICALLY <br />CONTINUOUS. <br />· PHOTOVOLTAIC ARRAYS SHALL BE PROVIDED <br />W/ DC GROUND-FAULT PROTECTION. <br />· DC GROUNDING ELECTRODE CONDUCTOR <br />SHALL BE SIZED ACCORDINGLY <br />· AC GROUNDING ELECTRODE CONDUCTOR <br />SHALL BE SIZED OR DWELLINGS <br />· GROUND BUSHINGS ARE REQUIRED AROUND <br />PRE-PUNCHED CONCENTRIC KNOCKOUTS ON <br />THE DC SIDE OF THE SYSTEM <br />· THE GROUNDING ELECTRODE CONDUCTOR <br />MUST BE PROTECTED FROM PHYSICAL <br />DAMAGE BETWEEN THE GROUNDING <br />ELECTRODE AND THE PANEL (OR INVERTER) IF <br />SMALLER THAN #6 COPPER WIRE <br />· THE GROUNDING ELECTRODE CONDUCTOR <br />WILL BE CONTINUOUS, EXCEPT FOR SPLICES <br />WITH IRREVERSIBLE COMPRESSION TYPE <br />CONNECTOR <br />· THE BACKFED PV BREAKER(S) AT THE MAIN <br />PANEL WILL BE INSTALLED AT THE OPPOSITE <br />END OF THE BUS BAR FROM THE MAIN <br />BREAKER AND THAT A PERMANENT <br />WARNING LABEL WITH THE FOLLOWING <br />MARKING WILL BE PROVIDED ADJACENT TO <br />THE BREAKER(S): "WARNING PHOTOVOLTAIC <br />CONNECTION. DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE." <br />DRAWING FOR ILLUSTRATION PURPOSE ONLY <br />GROUNDING NOTES <br />PREPARED BY:DATE: <br />PROJECT #: <br />SHEET NAME: <br />SHEET #: <br />PROPOSED EQUIPMENT:SCOPE OF WORK:HOMEOWNER: CONTRACTOR: <br />PV-G.02 <br />GROUNDING NOTES <br />#10-24 S.S. LOCK NUT <br />#10-24 S.S. EXTERNAL TOOTH <br />LOCK 'STAR' WASHER <br />#10-24 x 3 4" S.S. HCS BOLT <br />S.S. SET SCREW INCLUDED <br /> S.S. HARDWARE <br />'RAIL TO RAIL BONDING' <br />LAY IN LUG TERMINAL <br />AL/CU DUAL RATED <br />(TIN PLATED CU) <br />LOCKNUT <br />BONDING BASE <br />'SPLICE BAR' <br />'EMT' CONDUIT <br />'EMT' CONNECTOR <br />CONTINUOUS <br />GROUND STRIP <br />INSULATION <br /># 6 AWG BARE <br />CU WIRE <br />SEALING LOCKNUT <br />AS NEEDED <br />GROUND BUSHING <br />W/ LAY-IN LUG <br />## AWG BARE CU WIRE <br /># 6 AWG BARE CU WIRE <br />MICRO-INVERTER / OPTIMIZER <br />*SELF GROUNDED <br />BONDING BASE <br />'SPLICE BAR' <br />JUNCTION BOX <br />MODULE(TYP.) STANDARD RAIL <br />*SELF GROUNDED <br />LARSUN SOLAR <br />CSLB: #583458 (C-46) <br />ADDRESS: 439 E HARRISON ST. UNIT E <br />CITY|ZIP: CORONA | CA | 92879 <br />PHONE: (951) 298-9007 <br />best solar <br />3/15/2022 <br />HP-102 <br />INSTALL A NEW 10.56kW (DC)|9.74kW(AC)|9.76kW (CEC AC) PV SOLAR SYSTEM ON AN <br />(E) RESIDENTIAL ROOF. ALL WORK TO BE CONDUCTED UNDER AN ACTIVE CSLB LICENSE <br />& SHALL ADHERE TO ALL FEDERAL|STATE|LOCAL LAWS & CODES. PLEASE REFERENCE <br />ALL CODE(S) THROUGHOUT THIS PLAN SET FOR FULL COMPLIANCE. <br />THE ROD SELLON RESIDENCE <br />2329 PARK DR. <br />SANTA ANA | CA | 92707 <br />APN #: 14014234 <br />ALL-AMERICAN <br />SOLAR SERVICES <br />L.L.C. <br />x AJC <br /> (24) M SOLAR: HC 144BB-440W MOD. <br /> (24) SOLAREDGE: P485 OPTMZR. <br /> (1) SOLAREDGE: SE10000H-US INV. <br />2329 S. Park Drive <br />06/03/22
The URL can be used to link to this page
Your browser does not support the video tag.