My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2329 S Park Drive - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Park Dr
>
2329 S Park Dr
>
2329 S Park Drive - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:41:11 PM
Creation date
5/30/2025 8:00:53 AM
Metadata
Fields
Template:
Plan
Permit Number
20176224
101110490
Full Address
2329 S Park Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1/16" = 1'-0"1/16" = 1'-0" <br />MOUNTING & RACKING NOTES <br />·SEE ATTACHED MANUFACTURE DATA-SHEET(S) FOR RACKING SPECIFICATION(S) & MOUNTING INSTALLATION <br />·ALL WIRING IN THE BUILDING / STRUCTURE TO BE INSTALLED IN CONDUIT <br />·ALL CONDUIT MOUNTED ON THE EXTERIOR OF THE BUILDING SHALL BE SECURELY ATTACHED TO THE BUILDING <br />·LABELS TO BE LOCATED AT THE METER ALTERING THE "PRESENCE OF AN ALTERNATE POWER SOURCE" AT THE SERVICE PANEL <br />·EXISTING B-VENT TERMINATORS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE EXTENDED 12" ABOVE THE <br />MODULES' TOP SURFACE TO COMPLY W/ CMC 802.6.2(1) & CPC 509.2(1) <br />· EXISTING DWV PLUMBING VENT TERMINATORS, WHERE ADJACENT TO THE PROPOSED MODULES & MUST BE 12" MIN. FROM EDGE OF MODULES & BE <br />EXTENDED 6" ABOVE THE MODULES' TOP SURFACE TO COMPLY W/ CPC 906.1 <br />·TWO INDEPENDENT SUPPORT RAILS PER PANEL W/ PORTRAIT ORIENTATION, OR SHARED INTERMEDIATE RAILS W/ PANELS IN LANDSCAPE ORIENTATION <br />·COLD WATER GROUNDING CONNECTED W/IN 5' OF POINT OF ENTRANCE OF WATER INTO HOUSE <br />·RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END (CEC 250.64 (E)) <br />·MAXIMUM END CANTILEVER OF ALUMINUM SUPPORT RAIL TO BE VERIFIED WHEN TABLE SPAN IS SUBMITTED. ALLOWABLE SPAN IN THE ROOF WIND PRESSURE <br />ZONE OF THE CANTILEVER FOR DC EQUIPMENT INSTALLED ON THE ROOF, CONDUIT, WIRING SYSTEMS & RACEWAYS SHALL BE LOCATED AS CLOSE AS POSSIBLE <br />TO THE RIDGE, HIP, OR VALLEY & SHALL RUN FROM THE RIDGE, HIP OR VALLEY DIRECTLY TO AN OUTSIDE WALL. DC COMBINER BOXES SHALL BE LOCATED SO AS <br />TO MINIMIZE CONDUIT RUNS IN PATHWAYS BETWEEN ARRAYS. DC WIRING LOCATED INSIDE OF BUILDING SHALL BE METALLIC CONDUIT OR IN RACEWAYS & <br />SHALL BE RUN ALONG THE BOTTOM OF LOAD BEARING STRUCTURAL FRAMING MEMBERS WHERE EVER FEASIBLE <br />MOUNTING DETAIL <br />EQUIPMENT DETAIL <br />ELECTRICAL DETAIL <br />PREPARED BY: DATE: <br />PROJECT #: <br />SHEET NAME: <br />SHEET #: <br />PROPOSED EQUIPMENT:SCOPE OF WORK:HOMEOWNER: CONTRACTOR: <br />S <br />E <br />N <br />W <br />S <br />E <br />N <br />W <br />PV-D.01 <br />SYSTEM DETAILS <br />SCALE SCALE <br />PLACE SEALANT AROUND LAG BOLT & <br />UNDER STANDOFF BASE <br />(E) TAR & GRAVEL &/OR <br />ROLLED COMP. <br />CHEMLINK <br />E-CURB SYSTEM <br />PREDRILLED 3 <br />(2) <br />16 <br />5 <br />" HOLE <br />16 <br />2 <br />" S.S. LAG BOLT W/ <br />1 2" EMBEDMENT (MIN.) <br />IRONRIDGE: QBASE ROOF MOUNT W/ CHEM CURB <br />(TYP.) ROOF SHEATHING <br />FOR ROLLED COMP. | TAR & GRAVEL ROOF <br />(TYP.) ROOF FRAMING <br />IRONRIDGE: XR-10 RAIL(S) <br />NEMA 3R <br />JUNCTION BOX <br />3/4" EMT <br />RAN ON ROOFTOP <br />(EXACT LOCATION TO VARY) <br />·MEMBER SIZE: 2x6 RAFTER @ 24" O.C. <br />·MEMBER SPECIES: DOUGLAS FIR <br />·MEMBER GRADE: N/A <br />·RAIL SPAN: SEE DETAILS <br />SYSTEM PROCUREMENT <br /># OF MODULES 24 <br /># OF MID-CLAMPS {+/-} 34 <br /># OF END-CLAMPS {+/-} 28 <br />RAIL LENGTH (IN.) {+/-} 2304 <br /># OF ATTACH. {+/-} 56 <br />IRONRIDGE: QBASE ROOF MOUNT <br />W/ CHEMLINK CHEM CURB <br />· MOUNTS SET @ 4-FT O.C. <br />· TAR & GRAVEL <br />· SLOPE @ 11° <br />MSP | UTILITY <br />AC DISCONNECT 60A|240V <br />SOLAREDGE:SE10000H-US INVERTER #1 <br />1'-6" <br />1'-6" <br />1'-6" <br />1'-6" <br />1'-6" <br />3'-0" <br />MSP | UTILITY <br />AC DISCONNECT 60A|240V <br />SOLAREDGE:SE10000H-US INVERTER #1 <br />(E <br />) <br /> <br />P <br />A <br />T <br />I <br />O <br />(E <br />) <br /> <br />P <br />A <br />T <br />I <br />O <br />(E <br />) <br /> <br />P <br />A <br />T <br />I <br />O <br />(E <br />) <br /> <br />P <br />A <br />T <br />I <br />O <br />LARSUN SOLAR <br />CSLB: #583458 (C-46) <br />ADDRESS: 439 E HARRISON ST. UNIT E <br />CITY|ZIP: CORONA | CA | 92879 <br />PHONE: (951) 298-9007 <br />best solar <br />3/15/2022 <br />HP-102 <br />INSTALL A NEW 10.56kW (DC)|9.74kW(AC)|9.76kW (CEC AC) PV SOLAR SYSTEM ON AN <br />(E) RESIDENTIAL ROOF. ALL WORK TO BE CONDUCTED UNDER AN ACTIVE CSLB LICENSE <br />& SHALL ADHERE TO ALL FEDERAL|STATE|LOCAL LAWS & CODES. PLEASE REFERENCE <br />ALL CODE(S) THROUGHOUT THIS PLAN SET FOR FULL COMPLIANCE. <br />THE ROD SELLON RESIDENCE <br />2329 PARK DR. <br />SANTA ANA | CA | 92707 <br />APN #: 14014234 <br />ALL-AMERICAN <br />SOLAR SERVICES <br />L.L.C. <br />x AJC <br /> (24) M SOLAR: HC 144BB-440W MOD. <br /> (24) SOLAREDGE: P485 OPTMZR. <br /> (1) SOLAREDGE: SE10000H-US INV. <br />This item has been digitally <br />signed and sealed on <br />03/17/2022 <br />2329 S. Park Drive <br />06/03/22
The URL can be used to link to this page
Your browser does not support the video tag.