Laserfiche WebLink
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 <br />STATE OF CALIFORNIA <br />Outdoor Lighting <br />NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 <br />Page 3 of 8 <br />CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br />Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: <br />Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 <br />01 <br />Name or <br />Item Tag <br />02 <br />Complete Luminaire Description <br />03 <br />Watts per <br />luminaire1,2 <br />04 <br />How Wattage is <br />determined <br />05 <br />Total <br />number <br />luminaires² <br />06 <br />Luminaire Status³ <br />07 <br />Excluded <br />per <br />§140.7(a) <br />08 <br />Design Watts <br />09 <br />Cutoff Req. ≥ <br />6,200 initial lumen <br />output <br />§130.2(b)⁴ <br />10 <br />Field Inspector <br />Pass Fail <br />UU2 Pole Mount Fixture Linear 115 Mfr. Spec¹ 2 New 230 Exempt* <br />UU3 Pole Mount Fixture Linear 77 Mfr. Spec¹ 1 Altered 77 Exempt* <br />UU4 Pole Mount Fixture Linear 229 Mfr. Spec¹ 1 Altered 229 Exempt* <br />UU5 Pole Mount Fixture Linear 77 Mfr. Spec¹ 2 Altered 154 Exempt* <br />Total Designed Watts: 1,289 <br />* NOTES: Selections with a * require a note in the space below explaining how compliance is achieved. <br />EX: Luminaire is lighting a statue; EXCEPTION 2 to §130.2(b). <br />UU1 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). <br />UU2 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). <br />UU3 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). <br />UU4 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). <br />UU5 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). <br /> <br />¹ FOOTNOTES: Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per §130.0(c) <br />² For linear luminaires, wattage should be indicated as W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 05 instead of number of <br />luminaires. <br />³ Select “New” for new luminaires in a new outdoor lighting project or for added luminaires in an alteration. Select “Altered” for replacement luminaires in an alteration. Select <br />“Existing to Remain” for existing luminaires within the project scope that are not being altered and are remaining. Select “Existing Reinstalled” for existing luminaires which are <br />being removed and reinstalled as part of the project scope <br />⁴ Compliance with mandatory cutoff requirements is required for luminaires with initial lumen output ≥ 6,200 unless exempted by §130.2(b). <br />G. CUTOFF REQUIREMENTS (BUG) <br />This Section Does Not Apply <br />H. OUTDOOR LIGHTING CONTROLS <br />2020-160821 <br />12/07/20