My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2880 N Main St - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2880 N Main St
>
2880 N Main St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 5:15:14 AM
Creation date
5/30/2025 8:00:55 AM
Metadata
Fields
Template:
Plan
Permit Number
20171818
101104398
Full Address
2880 N Main St
Street Number
2880
Street Direction
N
Street Name
Main
Street Suffix
St
Document Relationships
101104398 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2880 N Main St
20171818 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2880 N Main St
Text box
ID:
1
Creator:
Import Agent
Created:
5/30/2025 4:42 PM
Modified:
5/30/2025 9:07 AM
Text:
http://www.energy.ca.gov/title24/2019standards
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 <br />STATE OF CALIFORNIA <br />Outdoor Lighting <br />NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 <br />Page 4 of 8 <br />CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br />Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: <br />Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 <br />Table Instructions: Complete this table demonstrating compliance with controls requirements for all new or altered luminaires installed as part of the permit application. For <br />alteration projects, luminaires which are existing to remain (ie untouched) and luminaires which are removed and reinstalled (wiring only) do not need to be included in this table <br />even if they are within the spaces covered by the permit application. <br />When an option having a * is selected, the notes section of this table must be completed. The lighting controls section of the Compliance Summary Table on the first page will <br />show "DOES NOT COMPLY" if the notes are left blank. For each requirement in columns 02 through 04, do not leave the field blank, instead select NA or Exempt* from the <br />dropdown list to indicate not applicable or an exemption. <br />Mandatory Controls <br />01 <br />Area Description <br />02 <br />Shut-Off <br />§130.2(c)1 <br />03 <br />Auto-Schedule <br />§130.2(c)2 <br />04 <br />Motion Sensor <br />§130.2(c)3 <br />05 <br />Field Inspector <br />Pass Fail <br />Parking Lot Photocontrol Yes - EMCS Exempt * <br />*NOTES: Controls with a * require a note in the space below explaining how compliance is achieved. <br />EX: Not permitted by health & safety to be turned off; EXCEPTION 1 to §130.2(c). <br />Parking Lot Lighting is required for compliance to California Finance Code Section 13000-13070 for footcandle requirements for ATM's. Dimming <br />fixtures would lower footcandles to below minimum requirements. <br />I. LIGHTING POWER ALLOWANCE (per §140.7) <br />Table Instructions: Please complete this table for areas using the <br />allowance calculations per §140.7. General Hardscape Allowance <br />is per Table 140.7-A while "Use it or lost it" Allowances are per <br />Table 140.7-B. Indicate which allowances are being used to <br />expand sections for user input. Luminaires that qualify for one of <br />the "Use it or lose it" allowances shall not qualify for another "Use <br />it or lose it" allowance. <br />01 <br />General <br />Hardscape <br />Allowance <br />✔ Per Application ✔ Sales Frontage Ornamental ✔ Per Specific Area✔ <br />"Use it or lose it" Allowances (select all that apply) <br />Table I (below) Table J Table K Table L Table M <br />Calculated General Hardscape Lighting Power Allowance per Table 140.7-A (LZ 2 & 3) <br />02 04 05 06 <br />Area Wattage Allowance (AWA) <br />Area Description Illuminated <br />Area (ft²) <br />Allowed Density <br />(W/ft²) <br />Area Allowance <br />(Watts) <br />03 <br />Surface Type <br />07 08 09 <br />Linear Wattage Allowance (LWA) <br />Perimeter <br />Length (lf) <br />Allowed Density <br />(W/lf) <br />Linear Allowance <br />(Watts) <br />10 <br />Total General <br />AWA + LWA <br />(Watts) <br />Sidewalk Concrete 0 0.03 0 0.4 0 0 <br />Parking Area Asphalt 26,953 0.025 673.825 0.25 0 673.825 <br />Table Continued <br />2020-160821 <br />12/07/20
The URL can be used to link to this page
Your browser does not support the video tag.