My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3606 S Ross Street - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Ross St
>
3606 S Ross St
>
3606 S Ross Street - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:43:23 PM
Creation date
5/30/2025 8:00:55 AM
Metadata
Fields
Template:
Plan
Permit Number
20176278
101110575
Full Address
3606 S Ross St
Document Relationships
101110575 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Ross St\3606 S Ross St
20176278 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Ross St\3606 S Ross St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Rev <br />PH <br />I <br /> <br />N <br />G <br />U <br />Y <br />E <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />36 <br />0 <br />6 <br /> <br />S <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />Date Description <br />REVISIONS <br />Signature with Seal <br />Project Name & <br />Address <br />Sheet Size <br />Sheet Number <br />ANSI B <br />11" X 17" <br />E 1.2 <br />Sheet Name <br />QC BY <br />---- <br />Initial Design 0004/11/2022 <br />SUNERGY, INC. <br />1 GAMELLA STREET, <br />LADERA RANCH CA, 92694 <br />PH. NO.- (562) 544-7394 <br />LICENSE NO.- 1061794 <br />NOTES <br />NOTES <br />120% RULE <br />BUS BAR RATING X 120%) - MAIN BREAKER RATING <br />= MAX. PV OCPD <br />(225A x 120%) - 200 = 70A <br />1. THIS SYSTEM SHALL COMPLY WITH ALL APPLICABLE CODES INCLUDING: THE 2019 <br />CALIFORNIA BUILDING CODE, CALIFORNIA FIRE CODE, CALIFORNIA ELECTRIC CODE, <br />CALIFORNIA MECHANICAL CODE CALIFORNIA RESIDENTIAL CODE, CALIFORNIA <br />PLUMBING CODE, CALIFORNIA BUILDING STANDARDS CODE, CALIFORNIA HEALTH AND <br />SAFETY CODE, IEEE STANDARD 929, UL STANDARD 1741, 2019 RESIDENTIAL CODE, AND <br />THE MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. <br />2. ALL WORK TO COMPLY WITH CEC ARTICLE 690 <br />3. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM <br />4. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT <br />DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE <br />CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR <br />5. ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY <br />6. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT <br />AT 25° C; WIRE SHALL BE WET RATED AT 90°C <br />7. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV <br />TYPE WIRE. <br />8. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS (NEC 314.15) <br />9. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY <br />CONTINUOUS (NEC 250.90, 250.96) <br />10. FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS <br />SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT <br />DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED, AND <br />AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO <br />AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS (CEC 690.35(C)) <br />11. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT <br />FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT (CEC 250.64C) <br />12. ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY <br />PHYSICAL DAMAGE <br />13. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND <br />MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE <br />SECURED BY REMOVABLE FASTENERS <br />14. FOR GROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT <br />PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION <br />15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE <br />BREAKERS SHALL NOT READ "LINE AND LOAD" <br />16. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT OF LESS THAN 4 PSF <br />17. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 45 LBS <br />18. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL <br />AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC <br />110.26 <br />19. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT <br />20. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED <br />ONTO THE EXISTING DWELLING AS PER THE 2016 CRC. THESE SMOKE ALARMS ARE <br />REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON <br />EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE <br />RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE <br />HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC <br />PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES <br />INSIDE THE HOME; OTHERWISE, THE ALARMS MUST BE HARD WIRED AND <br />INTERCONNECTED. (CRC R314, R315) <br />21. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS R314 <br />AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE FIELD. <br />22. WHEN APPLYING THE 120% RULE OF CEC 705.12(D)(2), THE SOLAR BREAKER TO BE <br />POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER <br />705.12(D)(7) <br />23. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY <br />SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED <br />OR OBSTRUCTED <br />THIS PANEL IS FED BY MULTIPLE SOURCES <br />(UTILITY AND SOLAR) <br />AC OUTPUT CURRENT <br />NOMINAL AC VOLTAGE 240V <br />ENPHASE Q CABLE TO BE ATTACHED TO <br />RAIL MIN. 3-1/2" ABOVE ROOF SURFACE <br />Rooftop conductor ampacities designed in compliance with <br />art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), <br />310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. <br />Location specific temperature obtained from ASHRAE 2017 <br />data tables <br />AMBIENT TEMP (HIGH TEMP 2%) <br />RECORD LOW TEMP 2° <br />31° <br />CONDUIT HEIGHT 0.5" <br />ROOF TOP TEMP 53° <br />CONDUCTOR TEMPERATURE RATE 90° <br />SYSTEM NOTES: <br />1. ENPHASE IQ8A-72-2-US, 240V, MICROINVERTERS DO NOT <br />REQUIRE GROUNDING ELECTRODE CONDUCTORS OR <br />EQUIPMENT GROUNDING CONDUCTORS. THE MICROINVERTERS <br />ITSELF HAS CLASS II DOUBLE-INSULATED RATING, WHICH <br />INCLUDES GROUND FAULT PROTECTION. <br />2. ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLE <br />INSULATED CABLING) <br />3. MODULES ARE BONDED TO RAIL USING IRONRIDGE INTEGRATED <br />GROUNDING. <br />4. RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS <br />5. SYSTEM IS UNGROUNDED <br />6. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA <br />IRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC <br />250.64(C) <br />7. SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTAL <br />BRANCH CIRCUIT. <br />8. ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRAL <br />TO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PER <br />ENPHASE INSTALLATION INSTRUCTIONS. <br />9. ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READY <br />PER CEC 690.12 <br />MICRO-INVERTER SPECIFICATIONS <br />MANUFACTURER <br />MAX. POWER AT 40 C <br />60 VOLTS <br />NOMINAL AC VOLTAGE <br />349 WATTS <br />MAX. AC CURRENT <br />240 VOLTS <br />MAX. OCPD RATING <br />MAX. PANELS/CIRCUIT <br />SHORT CIRCUIT CURRENT <br />1.45 AMPS <br />20 AMPS <br />MAX. DC VOLT RATING <br />11 <br />15 AMPS <br />ENPHASE IQ8A-72-2-US, 240V <br />PV MODULE RATING @ STC <br />MANUFACTURER <br />MAX. POWER-POINT CURRENT (IMP) <br />MAX. POWER-POINT VOLTAGE (VMP) <br />OPEN-CIRCUIT VOLTAGE (VOC) <br />SHORT-CIRCUIT CURRENT (ISC) <br />9.51 AMPS <br />42.1 VOLTS <br />48.8 VOLTS <br />10.10 AMPS <br />NOM. MAX. POWER AT STC (PMAX) <br />MAX. SYSTEM VOLTAGE <br />VOC TEMPERATURE COEFFICIENT <br />400 WATT <br />1000V <br />-0.24° %/°C <br />REC400AA PURE BLACK(400W) <br />3606 S. Ross <br />Street - Solar06/08/22
The URL can be used to link to this page
Your browser does not support the video tag.