My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3606 S Ross Street - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Ross St
>
3606 S Ross St
>
3606 S Ross Street - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:43:23 PM
Creation date
5/30/2025 8:00:55 AM
Metadata
Fields
Template:
Plan
Permit Number
20176278
101110575
Full Address
3606 S Ross St
Document Relationships
101110575 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Ross St\3606 S Ross St
20176278 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Ross St\3606 S Ross St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
N <br />Rev <br />PH <br />I <br /> <br />N <br />G <br />U <br />Y <br />E <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />36 <br />0 <br />6 <br /> <br />S <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />Date Description <br />REVISIONS <br />Signature with Seal <br />Project Name & <br />Address <br />Sheet Size <br />Sheet Number <br />ANSI B <br />11" X 17" <br />E 1.3 <br />Sheet Name <br />QC BY <br />---- <br />Initial Design 0004/11/2022 <br />SUNERGY, INC. <br />1 GAMELLA STREET, <br />LADERA RANCH CA, 92694 <br />PH. NO.- (562) 544-7394 <br />LICENSE NO.- 1061794 <br />WARNING <br />LABELS <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />MAIN SERVICE PANEL <br />UTILITY METER <br />36 <br />0 <br />6 <br /> <br />S <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />. <br />NOTES AND SPECIFICATIONS: <br />x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 <br />ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED <br />BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. <br />x SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING <br />EFFECTIVE WORDS, COLORS AND SYMBOLS. <br />x LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR <br />WIRING METHOD AND SHALL NOT BE HAND WRITTEN. <br />x LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED. <br />x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT <br />SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />x DO NOT COVER EXISTING MANUFACTURER LABELS. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED <br />ELECTRICAL SHOCK HAZARD <br />WARNING ! <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECTS. <br />PER CODE(S): CEC 2016: 690.35(F), NEC 2014: <br />690.35(F), NEC 2011: 690.35(F) <br />WARNING! <br />SOURCES: UTILITY GRID <br />AND PV SOLAR ELECTRIC <br />SYSTEM <br />DUAL POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN SERVICE <br />PANEL. <br />PER CODE(S): NEC 2014: 705.12(D)(3), <br /> NEC 2011: 705.12(D)(4) <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />LABEL LOCATION: <br />INVERTER(S), ENPHASE ENVOY ENCLOSURE <br />(IF APPLICABLE). <br />PER CODE(S): CEC 2019: 690.15, <br />NEC 2014: 690.5(C), NEC 2011: 690.5(C) <br />! <br />ELECTRICAL SHOCK HAZARD <br />WARNING ! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2019: 690.17(B), <br />NEC 2014: 690.17(E), NEC 2011: 690.17(4) <br />WARNING ! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF APPLICABLE). <br />PER CODE(S): CEC 2019: 705.12(B), <br />NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). <br />PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC <br />2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH <br />TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL <br />BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): CEC 2019: 690.13, NEC 2014: 690.31(G)(3), <br />690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: <br />605.11.1.4 <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2019: 690.53, NEC 2014: 690.54, NEC 2011: 690.54 <br />PHOTOVOLTAIC AC DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL <br />LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, <br />PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN <br />DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) <br />SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID <br />SHUTDOWN <br />TURN RAPID <br />SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV <br />SYSTEM AND <br />REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR <br />ELECTRIC <br />PV PANELS <br />COMBINER PANEL 4 <br />3606 S. Ross <br />Street - Solar06/08/22
The URL can be used to link to this page
Your browser does not support the video tag.