Laserfiche WebLink
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 <br />STATE OF CALIFORNIA <br />Outdoor Lighting <br />NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 <br />Page 3 of 9 <br />CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br />Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: <br />Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 <br />01 <br />Name or <br />Item Tag <br />02 <br />Complete Luminaire Description <br />03 <br />Watts per <br />luminaire1,2 <br />04 <br />How Wattage is <br />determined <br />05 <br />Total <br />number <br />luminaires² <br />06 <br />Luminaire Status³ <br />07 <br />Excluded <br />per <br />§140.7(a) <br />08 <br />Design Watts <br />09 <br />Cutoff Req. ≥ <br />6,200 initial lumen <br />output <br />§130.2(b)⁴ <br />10 <br />Field Inspector <br />Pass Fail <br />SH1 Wall Mount Fixture Linear 25 Mfr. Spec¹ 5 Altered 125 NA: <6,200 lumens <br />UU1 Pole Mount Fixture Linear 74.3 Mfr. Spec¹ 2 Altered 148.6 NA: <6,200 lumens <br />UU2 Pole Mount Fixture Linear 74.3 Mfr. Spec¹ 3 New 222.9 NA: <6,200 lumens <br />UU3 Pole Mount Fixture Linear 136.4 Mfr. Spec¹ 3 New 409.2 Yes <br />UU4 Pole Mount Fixture Linear 189 Mfr. Spec¹ 3 New 567 Yes <br />UU5 Pole Mount Fixture Linear 289.1 Mfr. Spec¹ 1 New 289.1 Exempt* <br />Linear 0 <br />Total Designed Watts: 2,225.4 <br />* NOTES: Selections with a * require a note in the space below explaining how compliance is achieved. <br />EX: Luminaire is lighting a statue; EXCEPTION 2 to §130.2(b). <br />UU5 Fixture is necessary for compliance with AB 244, banking security law; ECEMPTION 3 to 130.2(b). <br /> <br />¹ FOOTNOTES: Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per §130.0(c) <br />² For linear luminaires, wattage should be indicated as W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 05 instead of number of <br />luminaires. <br />³ Select “New” for new luminaires in a new outdoor lighting project or for added luminaires in an alteration. Select “Altered” for replacement luminaires in an alteration. Select <br />“Existing to Remain” for existing luminaires within the project scope that are not being altered and are remaining. Select “Existing Reinstalled” for existing luminaires which are <br />being removed and reinstalled as part of the project scope <br />⁴ Compliance with mandatory cutoff requirements is required for luminaires with initial lumen output ≥ 6,200 unless exempted by §130.2(b). <br />G. CUTOFF REQUIREMENTS (BUG) <br />Table Instructions: Complete this table for fixtures of ≥ 6,200 initial luminaire lumens indicated on Table F as needing to comply with Cutoff Requirements. Maximum lumens <br />can be found in Title 24, Part 11, Section 5.106.8. <br />Table Continued <br />2020-161485 <br />12/15/20