Laserfiche WebLink
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 <br />STATE OF CALIFORNIA <br />Outdoor Lighting <br />NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 <br />Page 2 of 9 <br />CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br />Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: <br />Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 <br />D. EXCEPTIONAL CONDITIONS <br />This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. <br /> <br />Table F. Outdoor Lighting Fixture Schedule Permit Applicant Notes: <br /> UU5: Fixture is necessary for compliance with AB 244, banking security law; ECEMPTION 3 to 130.2(b). <br />Table H. Outdoor Lighting Controls Permit Applicant Notes: <br /> Sidewalk Lighting <br />: Lighting is required for compliance to California Finance Code Section 13000-13070 for footcandle requirements for ATM's. Dimming fixtures would lower footcandles to below <br />minimum requirements. <br />E. ADDITIONAL REMARKS <br />This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. <br />F. OUTDOOR LIGHTING FIXTURE SCHEDULE <br />Table Instructions: For new or altered lighting systems demonstrating compliance with §140.7 (ie Table I has expanded for input), include all luminaires being installed and any <br />existing luminaires remaining or being moved within the spaces covered by the permit application in the Table below. For altered lighting systems using the Existing Power <br />method per §141.0(b)2L (ie Table N has expanded for input), include only new luminaires being installed and replacement luminaires being installed as part of the project scope <br />(ie, do not include existing luminaires remaining or existing luminaires being moved). <br />Designed Wattage: <br />01 <br />Name or <br />Item Tag <br />02 <br />Complete Luminaire Description <br />03 <br />Watts per <br />luminaire1,2 <br />04 <br />How Wattage is <br />determined <br />05 <br />Total <br />number <br />luminaires² <br />06 <br />Luminaire Status³ <br />07 <br />Excluded <br />per <br />§140.7(a) <br />08 <br />Design Watts <br />09 <br />Cutoff Req. ≥ <br />6,200 initial lumen <br />output <br />§130.2(b)⁴ <br />10 <br />Field Inspector <br />Pass Fail <br />BO1 Canopy Mount Fixture Linear 20 Mfr. Spec¹ 4 Altered 80 NA: <6,200 lumens <br />B02 Canopy Mount Fixture Linear 20 Mfr. Spec¹ 3 New 60 NA: <6,200 lumens <br />DX1 Canopy Mount Fixture Linear 11 Mfr. Spec¹ 9 Altered 99 NA: <6,200 lumens <br />DX2 Canopy Mount Fixture Linear 11 Mfr. Spec¹ 6 New 66 NA: <6,200 lumens <br />DZ1 Canopy Mount Fixture Linear 19.6 Mfr. Spec¹ 1 Altered 19.6 NA: <6,200 lumens <br />EK1 Ressed Canopy Mount Linear 32 Mfr. Spec¹ 2 Altered 64 NA: <6,200 lumens <br />SA1 Wall Mount Fixture Linear 25 Mfr. Spec¹ 3 Altered 75 NA: <6,200 lumens <br />Table Continued <br />2020-161485 <br />12/15/20