A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS. <br />THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM. <br />A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47, 250.50 THROUGH 60, AND 250.166 SHALL BE PROVIDED. PER CEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE <br />USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE <br />USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN <br />#8 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE OR A COMPLETE GROUND. <br />EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED BY THE MANUFACTURER. <br />EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH CEC 250.134 OR 250.136(A) REGARDLESS <br />OF VOLTAGE. <br />PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED PER CEC 110.26. <br />ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC. <br />HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6' 7" PER CEC 240.24. <br />THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER <br />WIRE PER CEC 250.64(B). THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER CEC 250.64(C). <br />ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES. <br />THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER CEC 705.12 (B)(2)(3)(b). <br />SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. DRAWINGS ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT OF <br />CONSTRUCTION. <br />PER THE CA RESIDENTIAL CODE (CRC) § R314 & R315, 10 YEAR BATTERY CARBON MONOXIDE AND SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING AREA AND HALLWAYS LEADING TO SLEEPING <br />AREAS. <br />WIRELESS <br />SYSTEM INFORMATION <br />SYSTEM SIZE <br />PV MODULES <br />RACKING <br />INVERTER(S) <br />ECOFASTEN ROCK IT <br />SHEET INDEX <br />IE-01 <br />IE-02 <br />IE-03 <br />IE-04 <br />TITLE SHEET <br />MOUNTING LAYOUT <br />ELECTRICAL DIAGRAM <br />IE-05 LABELING <br />APPLICABLE CODES <br />2019 CALIFORNIA ELECTRICAL CODE (CEC) <br />2019 CALIFORNIA BUILDING CODE (CBC) <br />LEGEND <br />SCOPE OF WORK <br />MOUNTING <br />EXISTING BUILDING INFORMATION <br />STRUCTURE TYPE: RESIDENTIAL OCCUPIED BUILDING <br />ROOF FRAMING: 2"X4" TRUSSES, 24" O.C <br />ROOF TYPE: <br />STORIES: 1 <br />CONSTRUCTION NOTES <br />M METER <br />INVERTER <br />GROUND <br />SWITCH <br />BREAKER <br />FUSE <br />CONDUIT RUN <br />VICINITY MAP <br />COMP SHINGLE <br />7 CANADIAN SOLAR: CS3U-395MS <br /> 7 ENPHASE ENERGY: IQ8PLUS-72-2-US <br />2019 CALIFORNIA RESIDENTIAL CODE (CRC) <br />ECOFASTEN ROCK IT <br />2.765 kW DC <br />SITE PLAN <br />INSTALLATION CONSISTS OF 7 CANADIAN SOLAR: CS3U-395MS PV <br />MODULES,7 MICRO INVERTERS AND RELATED ELECTRICAL METERING <br />(IF USED) AND SAFETY EQUIPMENT. <br />ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE <br />WARRANTED <br />ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLE <br />CODES AND LOCAL UTILITY COMPANY REQUIREMENTS. <br />AIR CONDITIONER <br />CHIMNEY <br />A/C <br />DESIGN CRITERIA <br />WIND SPEED: 95 MPH <br />SNOW LOAD: 0 PSF <br />PROJECT INFORMATION <br />AHJ SIGNATURE AND DATE <br />SHEET TITLE <br />SHEET NUMBER <br />PCGI <br />31566 Railroad Canyon Rd. <br />STE 2-29 <br />Canyon Lake, CA 92587 <br />CSLB#: 1074469 <br />DRAWN BY: <br />DATE: <br />NAME: <br />ADDRESS: <br />CITY: <br />STATE, ZIP: <br />AHJ: <br />FINANCE TYPE: <br />7/21/2022 <br />TITLE SHEET <br />IE-01 <br />APN#: <br />C7.8 <br />JAY.PEPITO <br />SAUL DELGADO <br />625 SOUTH BROADWAY UNIT #3 <br />SANTA ANA <br />CA,92701 <br />SUNNOVA <br />CITY OF SANTA ANA <br />JAY.PEPITO <br />01015307 <br />Bldg permit #101112459 <br />Elect permit #201777720 <br />Permits issued on 11/3/22 <br />625 S Broadway <br />11/03/22