Laserfiche WebLink
Power Optimizer <br />For North America <br />P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 <br />Optimizer model <br />(typical module <br />compatibility) <br />P320 <br />(for 60-cell <br />modules) <br />P340 <br />(for high- <br />power <br />60-cell <br />modules) <br />P370 <br />(for higher- <br />power <br />60 and 72- <br />cell <br />modules) <br />P400 <br />(for 72 & <br />96-cell <br />modules) <br />P401 <br />(for high <br />power 60 <br />and 72 cell <br />modules) <br />P405 <br />(for high- <br />voltage <br />modules) <br />P485 <br />(for high- <br />voltage <br />modules) <br />P505 <br />(for higher <br />current <br />modules) <br />INPUT <br />Rated Input DC Power(1)320 350 370 400 485 505 W <br />Absolute Maximum Input Voltage <br />(Voc at lowest temperature)48 60 80 60 125(2)83(2)Vdc <br />MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc <br />Maximum Short Circuit Current <br />(Isc)11 11.02 11 10.1 11.75 11 14 Adc <br />Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc <br />Maximum Efficiency 99.5 % <br />Weighted Efficiency 98.8 98.6 % <br />Overvoltage Category II <br />OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) <br />Maximum Output Current 15 Adc <br />Maximum Output Voltage 60 85 Vdc <br />OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) <br />Safety Output Voltage per Power <br />Optimizer 1 ± 0.1 Vdc <br />STANDARD COMPLIANCE <br />EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 <br />Safety IEC62109-1 (class II safety), UL1741 <br />Material UL94 V-0, UV Resistant <br />RoHS Yes <br />INSTALLATION SPECIFICATIONS <br />Maximum Allowed System <br />Voltage 1000 Vdc <br />Compatible inverters All SolarEdge Single Phase and Three Phase inverters <br />Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 <br />/ 5.1 x 6 x 1.3 <br />129 x 153 x 29.5 <br />/ 5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 <br />/ 5.1 x 6.4 x 2.3 <br />mm <br />/ in <br />Weight (including cables)630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb <br />Input Connector MC4(3)Single or dual <br />MC4(3)(4)MC4(3) <br />Input Wire Length 0.16 / 0.52 0.16 or 0.9 <br />/0.52 or 2.95(5)0.16 / 0.52 m / ft <br />Output Wire Type / Connector Double Insulated / MC4 <br />Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft <br />Operating Temperature Range(6)-40 to +85 / -40 to +185 ˚C / ˚F <br />Protection Rating IP68 / NEMA6P <br />Relative Humidity 0 - 100 % <br />(1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power ”. Modules with up to +5% power tolerance are allowed <br />(2) NEC 2017 requires max input voltage be not more than 80V <br />(3) For other connector types please contact SolarEdge <br />(4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to <br /> one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals <br />(5) Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx <br />(6) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details <br />PV System Design Using a <br />SolarEdge Inverter(7)(8) <br />Single Phase <br />HD-Wave Single phase Three Phase for <br />208V grid <br />Three Phase for <br />277/480V grid <br />Minimum String Length <br />(Power Optimizers) <br />P320, P340, P370, <br />P400, P401 8 10 18 <br />P405, P485, P505 6 8 14 <br />Maximum String Length (Power Optimizers)25 25 50(9) <br />Maximum Power per String <br />5700 (6000 with <br />SE7600-US - SE11400- <br />US) <br />5250 6000(10)12750(11) W <br />Parallel Strings of Different Lengths or Orientations Yes <br />(7) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf <br />(8) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string <br />(9) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement <br />(10) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W <br />(11) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W <br />© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. <br />All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2021 DS-000044-1.2-NA. Subject to change without notice. <br />405 <br />723 S Orange Ave <br />03/14/22