My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
723 S Orange Ave - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Orange Ave
>
723 S Orange Ave
>
723 S Orange Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 5:01:06 PM
Creation date
5/30/2025 8:01:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20175614
101109708
Full Address
723 S Orange Ave
Document Relationships
101109708 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Orange Ave\723 S Orange Ave
20175614 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Orange Ave\723 S Orange Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) <br />Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 <br />5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, <br />making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into <br />the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): <br /> If the cables at the top are red and black from left to right, connect as shown below. <br />Figure 2: Rapid shutdown cable connected – option 1 <br />If the cables at the top are black and red from left to right, connect as shown below. <br /> <br />Figure 3: Rapid shutdown cable connected – option 2 <br />6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection <br />spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from <br />the switch to the DC+ terminal block. <br />7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. <br />8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. <br />Red (+) Black (-) <br />Black (-) <br />DC+ DC- <br />Red (+) with rapid <br />shutdown resistor <br />Black (-) Red (+) <br />Black (-)Red (+) with rapid <br />shutdown resistor <br />DC+ DC- <br />723 S Orange Ave <br />03/14/22
The URL can be used to link to this page
Your browser does not support the video tag.