Project No. D-3885-06 <br />Christ Our Savior Catholic Parish <br />Grouting shall be sequenced so that grouting does not take place within l5 feet of <br />locations grouted in past 24 hours. <br />a <br />Quality Control <br />Quality control should be performed by the Site Superintendent ensuring that all <br />production data is present in the compaction grout logs and is in accordance with the <br />drawings. These logs were reviewed by Project Manager on a daily basis and provided to <br />the Engineer from General Contractor and also to our representative on daily basis. The <br />date of drilling and date of grouting for each Primary Holes should be tabulated in Table <br />and the detail daily grout logs should be presented, under supervision of Geotechnical <br />Engineer of Record. <br />Compaction of Upper Layer: <br />After compaction grouting is complete, the surficial subgrade soils should be over- <br />excavated and re-compacted to minimum 93 percent of ASTM D-1557, 3-feet below <br />bottom of mat footing. <br />Verification Testing (Cone Penetration Test or Hollow Stem Auger Drilling) <br />We propose to perfonn two cone penetration (CPT) soundings after the grouting to veriry <br />and check whether ground has been stabilized and the static settlernent as well as <br />liquefaction settlement are calculated to verifr that the settlements are drastically reduced. <br />Alternatively, hollow stem auger may be used to drill and get undisturbed sample to <br />verifu and document the increase in blow counts as well as the increased density and <br />calculate the new compression Index, Cc and other consolidation parameters to verift the <br />reduction in settlements. <br />3l <br />n <br />E <br />E <br />u <br />f <br />u <br />I <br />! <br />n <br />I <br />T <br />E <br />E <br />T <br />E <br />T <br />f <br />t-l <br />E <br />r Primary holes are grouted first followed by secondary holes, if necessary. <br />e Final Grouting Design should be reviewed by this office.