My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 S Standard Ave - Soils Report
PBA
>
Building
>
Soils Reports
>
S
>
Standard Ave
>
2215 S Standard Ave
>
2215 S Standard Ave - Soils Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2021 9:12:16 AM
Creation date
6/28/2021 9:12:10 AM
Metadata
Fields
Template:
Soils Report
Full Address
2215 S Standard Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Repon of Soils Investigation <br />221 5 South Standard Ave., Proposed Addition <br />Santa Ara. California <br />Page l8 of 27 <br />Job No 40-061 3 <br />April 5. 1999 <br />I <br />.1 <br />dependent on the type of compaction equipment utilized. Generally, fill soils <br />should be placed in uniform horizontal lifts not exceeding 8-inches in loose <br />thickness. Placement and compaction of fill should be performed in general <br />conformance with geotechnical recommendations and local ordinances. <br />10.2.8 Transition Pad Condition <br />Based on site elevations and materials present, there is no anticipated transition <br />condition. Based on all excavation recommendations, it is anticipated that all <br />footings will be founded on properly compacted materials. If deep foundations <br />are proposed, additional earthwork recommendations will be provided. <br />10.3 Foundation Design <br />Foundation and slabs should be designed in accordance with structural considerations and <br />the following recommendations. These recommendations assume that the soils exposed <br />at the finished pad grade will have a low potential for expansion as anticipated. <br />10.3.1 Footines <br />The proposed building may be supported by continuous and spread footings <br />founded at a minimum depth of 24 inches below the lowest adjacent subgrade. <br />Continuous footings should have a minimum width of 15 inches and be reinforced <br />with at least four No. 5 reinforcing bars, 2 top and 2 bottom. Isolated interior <br />footings should have a minimum width of 24 inches and be founded at a <br />minimum depth ol 24 inches belou, the lowest adjacent subgrade. No lootings <br />l <br />l <br />I <br />I.j <br />-)