My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179885_1247 S. MAIN - Plan
PBA
>
Building
>
Plans
>
M
>
Main St
>
1247 S Main St
>
10179885_1247 S. MAIN - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2021 11:51:23 AM
Creation date
10/25/2020 5:17:50 PM
Metadata
Fields
Template:
Plan
Permit Number
10179885
Full Address
1247 S Main St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
October 1, 2013 SIGN COMPONENTS MANUAL (SAM)134 <br />1. These products are only suitable for connection to a Class 2 power source, rated 30 Volt DC or less. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage <br />and energy limits and which is rated greater than 30 V DC. <br />3. These products are each rated max. 100 Watts per unit. When units are connected to a Class 2 circuit, they are not to draw a <br />total wattage of greater than the secondary or output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations when rated maximum 30 VDC. <br />5. These products are not required to be enclosed or protected from the weather in the end product when rated 30 VDC or less. <br />6. These products may be secured in place in the end product by any means available. <br />7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall <br />be considered. <br />LED Strips, Cat. No. 701174,701181 and 701i195 with suffix -R, -Y, -A, -B, -W or -G followed by -1" through -24" <br />1. These products are only suitable for connection to a UL Listed or Recognized Class 2,24 volt AG power source. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 <br />voltage and energy limited supplies. <br />3. These products may be cut into segments through a black mark provided on the printed wiring board. No other cut across the <br />board is permitted. <br />4. Cat. No. 701174 is rated for 4.2 watts per foot, Cat. No. 701181 is rated for 9.2 watts per foot and Cat. No. 701195 is rated at <br />1.5 Watts per' foot. T.he total number of feet of each type and inches for the inch unit are nbt to produce a total wattage of <br />greater than 60 watts per Class 2 circuit. <br />5. These products are suitable for use in dry, damp and wet locations. <br />6. These products are not required to be enclosed or protected from weather. <br />Class 2 LED Module, Cat. No 701946-XXYYYYYYZZZ series, where XX, YYYYYYand ZZZ may be replaced with any <br />alphanumeric characters or blank. <br />1. These products are suitable for use in dry, damp and wet locations and supplied only with a Class 2 power source rated 24 Volt <br />DC or less. <br />2. When units are connected toia Class 2 circuit, they are not to draw a total wattage of'greater than the secondary or output rating <br />of the Class 2 supply, <br />3. These products are not required to be enclosed or protected from the weather in the end product. <br />4. These products may be secured in place in the endl product by any means available. <br />Class 2 power supply. Model 701285. <br />1. Power supply is intended to power LEDs in signs. <br />2. Power supply model is intended for permanent connection only. <br />3. These units are suitable for use in dry location without a need for an additional endlosure and in damp locations when installed <br />inside a sign that complies with the Exclusion of Water Test in UL 48. <br />4. If the power supply output wiring is extended longer than the 5 foot leads provided, the spliced connections shall be made <br />inside a Listed junction box suitable for the application included with proper grounding. <br />Class 2 power supply: Cat. Nos. 701349, 701351. <br />1, Power supply models 701349 and 701351 are intended to power LEDs in signs. <br />2. Power supply model 701349 and 701351 are intended for permanent connection only <br />3. These units are' suitable for use In dry location without a need for an addjtional enclosure and in damp locations when installed <br />inside a sign that complies with the Exclusion of Water Test in UL 48. <br />5. These power supplies have two outputs. The Class 2 output circuits are riot to be conductively connected to each other in the <br />sign by wiring or other type of component. <br />6. The maximum rated output power for Model 701349 is 42 watts at each Class 2 output. The maximum rated output power fof <br />Model 701351 is 60 watts at each Class 2 output. <br />Class 2 power supplies, Models 701507-MOD, 701507-MOD277 (800603277/347-SLN). All may be followed by alphanumeric <br />suffix. <br />1. These power supplies have a maximum of one Class 2 output. The output of these power supplies has been evaluated to Class <br />2 Output requirements for dc circuits. <br />2. These products with Class 2 outputs are suitable for use in dry, damp -and wet locations. <br />3. In the end product, power supply spacing to other heat producing components shall be minimum 4 inches spacing to sidewalls, <br />and minimum 2 inches spacihg to top of enclosure. <br />4 When used in wet locations, each unit shall be provided with Listed (QCR\,9 1/2 inch, liquid tight conduit fittings oh primary <br />circuit. <br />5. When used in a cord connected product. the need for conducting a leakage current test shall be considered in the end product. <br />6. When not marked for Dry and Damp Locations Only the power supply primary bracket shall be provided with min. 3.5 threads <br />and maximum 5 threads tapered for connection lo liquid tight conduit fitting. If less than 3. 5 threads, the liquid tight shall be <br />provided with watertight fitting Listed (QCR\,9 1/2 inch, liquid tight conduit fittings. <br />7. The suitability of grounding connection shall be determined in the end-use product. <br />Class 2 power supply, Model 701680. <br />1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate <br />application. <br />2. These units are provided with a Class 105(A) insulation system. <br />3. The suitability of the input and output connections shall be determined in each end use application. <br />4. These power units are intended for dry or damp location use only <br />5. Strain Relief on input lead construction and Impact Tests have not been investigated. <br />6. The polymeric enclosure of each unit has riot been evaluated as ultimate enclosure. The flame class of pelymeric enclosure of <br />each unit is V-2, and the necessity of additional fire barriers shall be determined in end product. <br />7. Multiple power supplies shall be spaced at least 25mm (1 in.) end to end or 102min (4 in.) in other directions. If lesser spacings <br />are used, then the Temperature Test shall be conducted in the end use product. For reference the maximum enclosure (case) <br />temperature on Ihe power supply was 90°C when tested at 58.4° ambient. <br />Class 2 power supply, Model 701680-MIW, <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class.2 <br />output.
The URL can be used to link to this page
Your browser does not support the video tag.