FLOOR SINK <br />(SEE PLUMBING PLAN) <br />INSTALL NEW LAYER OF 5/8" GYP. BD FROM FLOOR <br />TO ROOF DECK & R-13 BATT. INSULATION WHILE <br />USING EXISTING WOOD STUDS TO COMPLETE 1-HR <br />FIRE BARRIER. ALL PENETRATIONS SHALL BE IN <br />ACCORDANCE WITH UL DETAILS. THE CONTRACTOR <br />SHALL PERMANENTLY LABEL EACH SIDE OF THE <br />DEMISING WALL ABOVE THE CEILING WITH 2" HIGH <br />LETTERS SPACED EVERY 12'-0". THE FOLLOWING <br />WORDING IS RECOMMENDED : <br />"1 HOUR FIRE AND SMOKE BARRIER PROTECT ALL <br />OPENINGS." <br />A SIGN CLEARLY STATING THAT SMOKING IS PROHIBITED <br />SHALL BE CONSPICUOUSLY POSTED BY THE BUILDING <br />OWNER, AGENT, OPERATOR, PERSON IN CHARGE OR <br />PROPRIETOR AT EACH ENTRANCE OR IN A POSITION CLEARLY <br />VISIBLE UPON ENTRY INTO THE BUILDING. ACCEPTABLE <br />SIGNS SHALL DISPLAY EITHER "NO SMOKING" OR THE <br />INTERNATIONAL "NO SMOKING SYMBOL (CONSISTING OF A <br />PICTORIAL REPRESENTATION OF A BURNING CIGARETTE <br />ENCLOSED IN A RED CIRCLE WITH A RED BAR ACRO <br />A5 <br />1 <br />TYPE I HOOD II SEE MECHANICAL <br />ALL BUSINESS TRANSACTION AREAS MUST MEET THE <br />REQUIREMENTS OF THE ACCESSIBILITY CODE WITH A <br />PORTION OF EACH TRANSACTION COUNTER CONSTRUCTED <br />WITH A SECTION OF THE COUNTER HAVING A MAXIMUM <br />HEIGHT OF 34" FOR A MINIMUM LENGTH OF 36". IT IS <br />RECOMMENDED THAT THIS ISSUE IS DISCUSSED WITH THE <br />BUILDING INSPECTOR PRIOR TO CONSTRUCTION AND/OR <br />INSTALLATION. <br />INSULATION NOTE: <br />CONTRACTOR SHALL INSULATE ALL FURRED OUT WALLS <br />THAT ARE AGAINST INTERIOR AND EXTERIOR MASONRY / <br />CONCRETE WALLS. CONTRACTOR SHALL ALSO INSULATE ALL <br />RESTROOM WALLS AND CEILIN <br />WALL BLOCKING/ BACKING NOTE: <br />ALL WALLS WITH SHELVING IN THE KITCHEN AREA AS WELL <br />AS ANY WALL WITH A WALL MOUNTED T.V. AND ANY <br />RESTROOM WALL WITH A MOUNTED FIXTURE SHALL HAVE <br />BACKING AND BLOCKING. (U.N <br />DIMENSIONAL NOTE: <br />* -EXISTING DIMENSION TO BE FIELD VERIFIED -ALL <br />DIMENSIONS PULLED FROM EXISTING BUILDING <br />WALLS ARE FROM THE FACE EXISTING MATE <br />CONTRACTOR SHALL LABEL ALL EXTERIOR DOORS <br />AND ELECTRICAL DISCONNECT WITH THE SUITE <br />NUMBER IN ACCORDANCE WITH THE INTERNATIONAL <br />BUILDING COD <br />TACTILE SIGNAGE: <br />PROVIDE EXIT TACTILE SIGNAGE IN ACCORDANCE WITH <br />NFPA-101:7.10.1.3, INTERNATIONAL FIRE PREVENTION CODE <br />AND ANSI A117.1, 2009 EDITIO <br />WALL BRACING NOTE: <br />ALL WALLS, OVER 6' IN HEIGHT, SHALL BE BRACED IN <br />ACCORDANCE WITH A-1 <br />WD <br />A3 <br />1 <br />AW1 <br />FRONT DOOR TO BE SELF-CLOSING <br />AND TIGHT FITTING. <br />RESTROOM DOOR TO SELF CLOSE <br />11B-404.2.5 THRESHOLDS <br />THRESHOLDS, IF PROVIDED AT DOORWAYS, <br />SHALL BE 1/2 INCH (12.7 MM) HIGH MAXIMUM. <br />RAISED THRESHOLDS AND CHANGES IN <br />LEVEL AT DOORWAYS SHALL COMPLY WITH <br />SECTIONS 11B-302 AND 11B-303. <br />PROVIDED FIRE RETARDANT TREATED <br />BLOCKING ON ALL WALLS IN THE <br />RESTROOM(S) & KITCHEN FOR <br />PLUMBING FIXTURES & ACCESSORIE <br />NEW WALK-IN COOLER -INSTALL <br />STAINLESS STEEL CLOSURE STRIPS AT <br />THE WALLS || CONTRACTOR SHALL <br />INSTALL WALK-IN WITH A MINIMUM OF <br />2" CLEARANCE TO GYPSUM BOARD <br />WALLS <br />A <br />A5.1 <br />B <br />A5.1 <br />ADD DIAMOND PLATE <br />KICK-PLATE TO WALK-IN <br />COOLER DOOR <br />"THE SUITE LETTER <br />OF THE SUITE WILL <br />BE POSTED ON THE <br />EXTERIORS OF <br />FRONT AND BACK <br />EXIT DOORS TO <br />IDENTIFY THE SUITE." <br />"PROVIDE SIGN ABOVE INTERIOR OF DOOR <br />STATING, "THIS DOOR TO REMAIN UNLOCKED <br />WHEN BUILDING IS OCCUPIED."" <br />58 <br />' <br />- <br />5 <br />" <br />4'-11"12'-6" <br />THE MAIN EXTERIOR DOOR OR DOORS ARE <br />PERMITTED TO BE EQUIPPED WITH KEY-OPERATED <br />LOCKING DEVICES THAT ARE READILY <br />DISTINGUISHABLE FROM THE EGRESS SIDE AND A <br />SIGN IS POSTED STATING: “THIS DOOR TO REMAIN <br />UNLOCKED WHEN THIS SPACE IS OCCUPIED.” THE <br />SIGN SHALL BE IN LETTERS 1”HIGH ON A <br />CONTRASTING BACKGROUND. (CBC 1010.1.9.4) <br />INTERNATIONAL SYMBOL <br />OF ACCESSIBILITY <br />2'-10" HIGH COUNTER, 36" LONG <br />ENTRY DOOR REQUIREMENTS <br />ALL ENTRANCES AND EXTERIOR GROUND-FLOOR EXITS TO <br />BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE <br />TO PERSONS WITH DISABILITIES IN ACCORDANCE WITH <br />SECTION 11B-206.4. ENTRANCE DOORS, DOORWAYS AND <br />GATES SHALL COMPLY WITH SECTION 11B-404 AND SHALL <br />BE ON AN ACCESSIBLE ROUTE COMPLYING WITH SECTION <br />11B-402. (CBC 11B-206.4) <br />A. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH <br />OF 32”MEASURED BETWEEN THE FACE OF THE <br />DOOR AND THE STOP; WITH THE DOOR OPEN 90 <br />DEGREES. (CBC 11B-404.2.3) <br />B. THE FLOOR OR LANDING SHALL BE NOT MORE <br />THAN ½”LOWER THAN THE THRESHOLD OF THE <br />DOORWAY. CHANGE IN LEVEL BETWEEN ¼“AND <br />½“SHALL BE BEVELED WITH A SLOPE NO GREATER <br />THAN ONE UNIT VERTICAL TO 2 UNITS HORIZONTAL <br />(50% SLOPE). (CBC 11B-303.2, 11B-303.3, <br />11B-404.2.5) PROVIDE DETAIL ON PLANS. <br />C. THE LEVEL AREA (2% MAXIMUM SLOPE IN ANY <br />DIRECTION) FOR MANEUVERING CLEARANCES AT <br />DOORS SHALL HAVE A LENGTH IN THE DIRECTION <br />OF DOOR SWING OF AT LEAST 60”AND THE <br />LENGTH OPPOSITE THE DIRECTION OF DOOR <br />SWING OF 48”AS MEASURED AT RIGHT ANGLES TO <br />THE PLANE OF THE DOOR IN ITS CLOSED POSITION. <br />(CBC 11B-404.2.4) <br />D. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO <br />WHICH THE DOOR SWINGS SHALL EXTEND 24 <br />INCHES PAST THE STRIKE EDGE OF THE DOOR FOR <br />EXTERIOR DOORS AND 18 INCHES PAST THE <br />STRIKE EDGE FOR INTERIOR DOORS. (CBC <br />11B-404.2.4) THE WIDTH OF THE LEVEL AREA ON <br />THE SIDE TO WHICH THE DOOR SWINGS AWAY <br />SHALL EXTEND 12 INCHES PAST THE STRIKE EDGE <br />IF THE DOOR IS EQUIPPED WITH BOTH A LATCH <br />AND A CLOSER PER CBC FIGURE 11B-404.2.4.1. <br />E. HAND-ACTIVATED DOOR OPENING HARDWARE, <br />HANDLES, PULLS, LATCHES, LOCKS AND OTHER <br />OPERATING DEVICES ON ACCESSIBLE DOORS <br />SHALL BE OPERABLE WITH ONE HAND AND SHALL <br />NOT REQUIRE TIGHT GRASPING, PINCHING OR <br />TWISTING OF THE WRIST. (CBC 11B-309.4, <br />11B-404.2.7) <br />3'-0" <br />7' <br />- <br />1 <br />1 <br />" <br />2' <br />- <br />8 <br />" <br />35 <br />' <br />- <br />4 <br />" <br />3' <br />- <br />7 <br />" <br />2' <br />- <br />8 <br />" <br />6' <br />- <br />4 <br />" <br />2'-2"8'-1" <br />7'-2" <br />SPACES AND ELEMENTS WITHIN EMPLOYEE <br />WORK AREAS SHALL ONLY BE REQUIRED <br />TO COMPLY WITH SECTIONS 11B-207.1, <br />11B-215.3, 11B-302, 11B-303, 11B-308.1.1, <br />11B-308.1.2 11B-404.2.3 AND SHALL BE <br />DESIGNED AND CONSTRUCTED SO THAT <br />INDIVIDUALS WITH DISABILITIES CAN <br />APPROACH, ENTER, AND EXIT THE <br />EMPLOYEE WORK AREA. (CBC 11B-203.9) <br />THE CLEAR WIDTH OF WALKING SURFACES <br />SHALL BE 36”MINIMUM. (CBC 11B-403.5.1) <br />8 <br />A5.2 <br />7 <br />A5.2 <br />LOCKERS <br />30"x48" <br />11B-305.1 General <br />Clear floor or ground space shall comply with Section 11B-305. <br />11B-305.2 Floor or Ground Surfaces <br />Floor or ground surfaces of a clear floor or ground space shall comply with Section <br />11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not <br />be permitted. <br />11B-305.3 Size <br />The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches <br />(1219 mm) minimum. <br />3 <br />3'-0" <br />FEC <br />LOBBY <br />01 <br />RESTROOM <br />05 <br />FEC <br />7' <br />- <br />1 <br />0 <br />" <br /> <br />4 <br />' <br />- <br />8 <br />" <br />37 <br />' <br />- <br />1 <br />1 <br />" <br />7' <br />- <br />1 <br />1 <br />" <br />24" <br />30 <br />" <br />x <br />4 <br />8 <br />" <br />FLOOR PLAN <br />(E) 1-HOUR RATED CORRIDOR PARTITION <br />PROVIDE 1-HOUR FIRE PROTECTION FOR ALL <br />PENETRATIONS <br />(E) WALL TO REMAIN <br />1i NEW WALL TYPE <br />INFILL OF EXISTING WALL <br />NEW ELECTRICAL / AUDIO-VIDEO COMPONENT: <br />SEE CONSULTANT PLANS FOR MORE INFORMATION. <br />NEW PLUMBING FIXTURE: <br />SEE CONSULTANT PLANS FOR MORE INFORMATION. <br />NEW STORAGE / CASEWORK: <br />SEE FINISH INTERIOR ELEVATIONS AND ROOM <br />FINISH SCHEDULE A4 <br />FEC FIRE EXTINGUISHER CABINET <br />*PLEASE PROVIDE AT LEAST ONE 2A:10B:C FIRE EXTINGUISHER <br />IN A CENTRAL LOCATION OF THE SUITE AND ANOTHER, CLASS <br />K, EXTINGUISHER NEAR THE COOKING EQUIPMENT. (IF USING <br />GREASE FRYING EQUIPMENT) <br />DOOR TAG SEE DOOR SCHEDULE A2### <br />ADA DOOR CLEARANCE <br />(E) SUITE DEMISING PARTITION -BUILD <br />PARTITION TO UNDERSIDE OF FLOOR DECK <br />STRUCTURE ABOVE. <br />(N) PARTITION WALL METAL STUD @ 16" O.C. <br />(SEE DETAIL 1/AW1)3 <br />A CB <br />DOOR TYPES <br />2" <br />VARIES <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />1' <br />- <br />0 <br />" <br />ALUM. <br />STOREFRONT <br />W/ FULL <br />LIGHT <br />2" <br />TYP <br />FRAME, SEE <br />SCHEDULEWOOD DOOR <br />HOLLOW <br />CORE <br />METAL <br />DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE SEE SCHEDULESEE SCHEDULE <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />Scale <br />Project number <br />Date <br />Drawn by <br />Checked by <br />This document, and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of Everett Smith, and is not to be used in whole or <br />in part, for any other project without the written authorization <br />of Everett Smith/ ESDESIGNS. All Rights Reserved <br />PREPARED BY: <br />Email: everett@everettsmithdesigns.com <br />PROJECT: <br />CLIENT NAME: <br />PROJECT ADDRESS: <br />REVISIONS: <br />IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. HIDDEN CONDITIONS MAY EXIST, AND ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY AND BRING TO THE DESIGNERS ATTENTION. <br />MENIFEE, CA 92584 <br />EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH DDDDEEEESSSSIIIIGGGGNNNNSSSS,,,, IIIINNNNCCCC <br />2023 <br />DDDDD S E <br />30141 ANTELOPE RD. D774 <br />8/2/2024 5:40:35 PM <br />As indicated <br />8/ <br />2 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />5 <br />: <br />4 <br />0 <br />: <br />3 <br />5 <br /> <br />P <br />M <br />Z:\Shared\Everett Smith Designs\___ES Design Jobs\23-2292 BCAL Marcos Orange\23-2292 Orange Marcos Pizza 2024.07.25.rvt <br />A2 <br />FLOOR PLAN <br />23-2292 <br />J.D. PHAM <br />RS <br />ES <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br />MA <br />R <br />C <br />O <br />S <br /> <br />P <br />I <br />Z <br />Z <br />A <br />100 N.HARBOR BLVD. <br />SUITE C-3 <br />SANTA ANA CA 92703 <br />1/4" = 1'-0"1 PROPOSED PLAN <br />DOOR SCHEDULE <br />Mark Description Door Type Finish Width <br />Lock <br />set <br />Frame Type / <br />Finish Frame Material <br />3' - 0" <br />16 WOOD, PAINT GRADE 1-3/4" Thick, Solid <br />Core Construction <br />3070 3' - 0" <br />O-06 0' - 0" <br />REACH IN REQUIREMENTS <br />1. ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY <br />THE OCCUPANT TO CONTROL; LIGHTING AND RECEPTACLE OUTLETS, <br />APPLIANCES OR COOLING, HEATING ELECTRICAL CONTROLS AND <br />SWITCHES INTENDED TO BE USED BY THE OCCUPANT TO CONTROL; <br />LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, <br />HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED WITHIN <br />ALLOWABLE REACH RANGES AND SHALL COMPLY WITH CBC <br />11B-308.1.1 REFER TO DETAIL 16 ON SHEET A-6. <br />2. ELECTRICAL RECEPTACLES OUTLETS ON BRANCH CIRCUITS OF 30 <br />AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES <br />SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES AND SHALL <br />COMPLY WITH CBC 11B-308.1.2. REFER TO DETAIL 16 AND SHEET A-6. <br />11B-404.2.7 DOOR AND GATE HARDWARE <br />HANDLES, PULLS, LATCHES, LOCKS, AND <br />OTHER OPERABLE PARTS ON DOORS AND <br />GATES SHALL COMPLY WITH SECTION <br />11B-309.4. OPERABLE PARTS OF SUCH <br />HARDWARE SHALL BE 34 INCHES (864 MM) <br />MINIMUM AND 44 INCHES (1118 MM) MAXIMUM <br />ABOVE THE FINISH FLOOR OR GROUND. <br />WHERE SLIDING DOORS ARE IN THE FULLY <br />OPEN POSITION, OPERATING HARDWARE <br />SHALL BE EXPOSED AND USABLE FROM <br />BOTH SIDES. <br />EXCEPTIONS: <br />1. EXISTING LOCKS SHALL BE PERMITTED <br />IN ANY LOCATION AT EXISTING GLAZED <br />DOORS WITHOUT STILES, EXISTING <br />OVERHEAD ROLLING DOORS OR <br />GRILLES, AND SIMILAR EXISTING <br />DOORS OR GRILLES THAT ARE <br />DESIGNED WITH LOCKS THAT ARE <br />ACTIVATED ONLY AT THE TOP OR <br />BOTTOM RAIL. <br />2. ACCESS GATES IN BARRIER WALLS <br />AND FENCES PROTECTING POOLS, <br />SPAS, AND HOT TUBS SHALL BE <br />PERMITTED TO HAVE OPERABLE <br />PARTS OF THE RELEASE OF LATCH ON <br />SELF-LATCHING DEVICES AT 54 INCHES <br />(1372 MM) MAXIMUM ABOVE THE FINISH <br />FLOOR OR GROUND PROVIDED THE <br />SELF-LATCHING DEVICES ARE NOT <br />ALSO SELF-LOCKING DEVICES AND <br />OPERATED BY MEANS OF A KEY, <br />ELECTRONIC OPENER, OR INTEGRAL <br />COMBINATION LOCK. <br />11B-404.2.9 DOOR AND GATE OPENING <br />FORCE THE FORCE FOR PUSHING OR <br />PULLING OPEN A DOOR OR GATE SHALL BE <br />AS FOLLOWS: <br />1. INTERIOR HINGED DOORS AND GATES: <br />5 POUNDS (22.2 N) MAXIMUM. <br />2. SLIDING OR FOLDING DOORS: 5 <br />POUNDS (22.2 N) MAXIMUM. <br />3. REQUIRED FIRE DOORS: THE MINIMUM <br />OPENING FORCE ALLOWABLE BY THE <br />APPROPRIATE ADMINISTRATIVE <br />AUTHORITY, NOT TO EXCEED 15 <br />POUNDS (66.7 N). <br />4. EXTERIOR HINGED DOORS: 5 POUNDS <br />(22.2 N) MAXIMUM. <br />THESE FORCES DO NOT APPLY TO THE <br />FORCE REQUIRED TO RETRACT LATCH <br />BOLTS OR DISENGAGE OTHER DEVICES <br />THAT HOLD THE DOOR OR GATE IN A <br />CLOSED POSITION. <br />WINDOWS ARE FIXED <br />AND NON-OPERABLE <br />No. Description Date <br />3 BUILDING <br />CORR. <br />2024.05.15 <br />100 N Harbor Blvd #C-3 - <br />101118438, 20182225, <br />30146961, 4013888710/31/2024