LEGEND <br />CT-1 <br />USG FROST -SEE FINISH SCHEDULE <br />2x2, PAINT DIFFUSER WITH RUSTOLEUM <br />TO MATCH <br />GYP BD. CEILING <br />HEIGHT OF CEILING / SOFFIT+ X'-X" <br />SUPPLY AIR DIFFUSER (SEE HVAC PLANS) <br />RETURN AIR DIFFUSER (SEE HVAC PLANS) <br />LIGHT FIXTURES PER ELECT. DWGS. <br />"WM" DESIGNATES WALL-MOUNTED & <br />"UC" DESIGNATES UNDER-CABINET <br />SHADED FIXTURE SYMBOLS INDICATE <br />FIXTURE IS CONNECTED TO THE LIFE <br />SAFETY SYSTEM <br />CEILING ACCESS PANEL <br />EXIT SIGNAGE PER ELECTRICAL DRAWINGS <br />CT-2 <br />VINYL FACED GYP BD PANELS WHITE <br />2x4 (KITCHEN CEILING), STAINLESS STEEL <br />AROUND EXHAUST DUCTS <br />LT7 <br />LT5 <br />LT8 <br />CT-2 <br />CT-2 <br />CEILING TILE , REFER TO <br />FINISH SCHEDULE. <br />UPLIFT PREVENTION CLIP. <br />CEILING TILE , REFER TO <br />FINISH SCHEDULE. <br />8'-3 3/4" <br />T.O. WALK-IN COOLER <br />PER PLAN <br />B.O. CEILING <br />P-3 <br />6" <br />8" MAX. <br />3 5/8" MTL WALL STUD. <br />#10 TEK SCREW @ EA STUD. <br />CEILING GRID RUNNER. <br />PERIMETER HANGER WIRE. <br />#10 SCREW @ EA STUD. <br />5/8" GYP BD. <br />WALL TRACK. <br />PAINT , REFER TO <br />FINISH SCHEDULE. <br />8'-0" AFF <br />BOTTOM OF SOFFIT <br />8'-6" AFF <br />BOTTOM OF CEILING <br />LIGHTING WITHIN THE WALK-IN TO <br />BE PROVIDE BY THE WALK-IN <br />MANUFACTURER & INSTALLED BY <br />THE ELECTRICAL CONTRACT <br />CT-1: 2'x2' <br />CEILING SYST <br />CT-2: 2'x4' CEILING SYST <br />LT5 <br />A951 <br />5 <br />4 <br />A951 <br />4 <br />A951A951 <br />5 <br />LT5 <br />LT7 <br />A <br />A5.1 <br />B <br />A5.1 <br />BY WALK-IN <br />SUPPLIER <br />BY WALK-IN <br />SUPPLIER <br />1 <br />AW1 <br />WD <br />A3 <br />5 <br />A951 1 <br />A951 <br />5 <br />A951 <br />LT8 LT8 <br />LT8 <br />LT8 <br />LT8LT8 <br />LT8 <br />2 <br />A951 <br />6 <br />A951 <br />5 <br />A951 <br />20 GA. METAL STUD TRACK <br />W/ RAMSET - 0.177" SHANK <br />x 1" SHOT PINS @ 24" O.C. <br />(ICC ESR-1166 OR EQUAL.) <br />OR 1/4" DIA. x 3.5" LONG @ <br />24" OC. <br />2x BLKG @ 48" O.C. W/ (N) T.N. <br />EA END, WHERE OCCURS. <br />3-5/8" x20 GA @ 16" <br />O.C. METAL STUDS W/ <br />MATCHING RUNNER <br />TRACK ICC-ESR-1166 <br />OR EQUAL <br />1/2 GYPSUM BOARD <br />W/ 5d COOLER NAIRS <br />@ 8"O.C. TO ALL <br />FRM'G MEMBERS <br />(E) CONC. FLOOR <br />VA <br />R <br />I <br />E <br />S <br />3.SEAL ALL PENETRATIONS <br />EXCEPT AT STUDS. <br />NO GYP. BD. JTS. <br />TO RUN VERTICALLY. <br />ALL GYP. BD. JTS. <br />TYPICAL NOTES <br />2. <br />1. <br />(E) CEILING JOISTS <br />CONT. TRACK <br />RUNNER W/ 2#8 <br />SCREWS @ 16" O.C. <br />FIRE STOP SEALANT <br />GLASS FIBER INSULATION <br />(OPTIONAL) <br />3/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />HEAD OF WALL - 1 HR <br />UL DESIGN: HW-D-0079 <br />UL DESIGN: HW-D-0083 <br />PARTITION - 1HR <br />UL DESIGN: U465 <br />UL DESIGN: V438 <br />NOTE: WHERE STUDS <br />ARE OVER 14'-0" IN <br />HEIGHT USE 3-5/8" x 22 GA <br />STUDS @ 16" O.C. <br />Scale <br />Project number <br />Date <br />Drawn by <br />Checked by <br />This document, and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of Everett Smith, and is not to be used in whole or <br />in part, for any other project without the written authorization <br />of Everett Smith/ ESDESIGNS. All Rights Reserved <br />PREPARED BY: <br />Email: everett@everettsmithdesigns.com <br />PROJECT: <br />CLIENT NAME: <br />PROJECT ADDRESS: <br />REVISIONS: <br />IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. HIDDEN CONDITIONS MAY EXIST, AND ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY AND BRING TO THE DESIGNERS ATTENTION. <br />MENIFEE, CA 92584 <br />EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH DDDDEEEESSSSIIIIGGGGNNNNSSSS,,,, IIIINNNNCCCC <br />2023 <br />DDDDD S E <br />30141 ANTELOPE RD. D774 <br />8/2/2024 5:40:36 PM <br />As indicated <br />8/ <br />2 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />5 <br />: <br />4 <br />0 <br />: <br />3 <br />6 <br /> <br />P <br />M <br />Z:\Shared\Everett Smith Designs\___ES Design Jobs\23-2292 BCAL Marcos Orange\23-2292 Orange Marcos Pizza 2024.07.25.rvt <br />A3 <br />R.C.P. <br />23-2292 <br />J.D. PHAM <br />RS <br />ES <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br />MA <br />R <br />C <br />O <br />S <br /> <br />P <br />I <br />Z <br />Z <br />A <br />100 N.HARBOR BLVD. <br />SUITE C-3 <br />SANTA ANA CA 92703 <br />COLOR VINYL FACED GYP BD PANELS WHITE <br />SIZE 2X4 <br />ITEM # <br />CT-2 09 51 00 MANUFA... ARMSTRONG <br />COLOR FACTORY FINISH - PER FINISH SCH. <br />SIZE 2X2 <br />ITEM # <br />CT-1 09 51 00 MANUFA...ARMSTRONG <br />CODE SPECIFICATION DESCRIPTION <br />09 51 00 ACOUSTICAL CEILINGS <br />1 1/2" = 1'-0"2 Ceiling to Walk-In Cooler <br />3" = 1'-0"3 Soffit Restroom <br />R.C.P. GENERAL NOTES: <br />1. ALL ELECTRIC FOR SIGNAGE TO BE PROVIDED BY THE CONTRACTOR. <br />2. COORDINATE ALL LIGHTING WITH TH ELECTRICAL DRAWINGS. <br />3. U.N.O. ALL SUSPENDED LIGHT FIXTURES TO BE CENTERED ABOVE <br />TABLES OR IN SPACE AS SHOWN. <br />4. ALL EMERGENCY LIGHTING TO BE INSTALLED AT LOCATIONS <br />INDICATED ON ELECTRICAL DRAWINGS. <br />5. ALL LIGHTS ABOVE ALL FOOD PREP / COOK / SERVE AREAS MUST <br />HAVE A SHATTERPROOD LENS INSTALLED. <br />1/4" = 1'-0"1 RCP <br />3/4" = 1'-0"WD 1-HR RATED DEMISING WALL DETAIL <br />REFLECTED CEILING NOTES: <br />SUSPENDED CEILINGS ARE BEING USED WITHIN THE <br />PROPOSED TENANT <br />IMPROVEMENT. PLEASE PROVIDE NOTES ON THE PLANS <br />TO SHOW THE SUSPENDED CEILINGS IN SEISMIC <br />DESIGN CATEGORIES D, E & F COMPLY WITH ASCE 7-16 <br />SECTION 13.5.6.2.2 AS FOLLOWS: <br />A. THE WIDTH OF THE PERIMETER SUPPORTING <br />CLOSURE ANGLE OR CHANNEL SHALL BE NOT LESS <br />THAN 2.0 IN. UNLESS QUALIFIED PERIMETER <br />SUPPORTING CLIPS ARE USED. <br />B. CLOSURE ANGLES OR CHANNELS SHALL BE <br />SCREWED OR OTHERWISE POSITIVELY <br />ATTACHED TO WALL STUDS OR OTHER SUPPORTING <br />STRUCTURES. PERIMETER SUPPORTING CLIPS SHALL <br />BE QUALIFIED IN ACCORDANCE WITH APPROVED TEST <br />CRITERIA PER SECTION 13.2.5. <br />C. PERIMETER SUPPORTING CLIPS SHALL BE ATTACHED <br />TO SUPPORTING CLOSURE ANGLE OR CHANNEL WITH A <br />MINIMUM OF TWO SCREWS PER CLIP AND SHALL BE <br />INSTALLED AROUND THE ENTIRE CEILING PERIMETER. <br />D. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE <br />END OF THE CEILING GRID SHALL BE ATTACHED TO THE <br />CLOSURE ANGLE, CHANNEL, OR PERIMETER <br />SUPPORTING CLIP. THE OTHER END OF THE CEILING <br />GIRD IN EACH HORIZONTAL DIRECTION SHALL HAVE A <br />MINIMUM 0.75-IN CLEARANCE FROM THE WALL AND <br />SHALL REST UPON AND BE FREE TO SLIDE ON A <br />CLOSURE ANGLE, CHANNEL, OR PERIMETER <br />SUPPORTING CLIP. <br />E. CEILING AREAS OVER 2500 FT.² MUST HAVE SEISMIC <br />SEPARATION JOINTS OR FULL HEIGHT PARTITIONS. <br />F. CEILINGS WITHOUT RIGID BRACING MUST HAVE 2” <br />OVERSIZE TRIM RINGS FOR SPRINKLERS AND OTHER <br />CEILING PENETRATIONS. <br />No. Description Date <br />100 N Harbor Blvd #C-3 - <br />101118438, 20182225, <br />30146961, 4013888710/31/2024