Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)1084 @ 2"12031 (3.50")Passed (9%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)518 @ 1' 3"6452 Passed (8%)0.90 1.0 D (All Spans) <br />Moment (Ft-lbs)1287 @ 3' 6 1/2"12274 Passed (10%)0.90 1.0 D (All Spans) <br />Live Load Defl. (in)0.003 @ 3' 6 1/2"0.225 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in)0.013 @ 3' 6 1/2"0.338 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />System : Floor <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2018 <br />Design Methodology : ASD <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Stud wall - DF 3.50"3.50"1.50"800 283 1084 Blocking <br />2 - Stud wall - DF 3.50"3.50"1.50"800 283 1084 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)7' 1" o/c <br />Bottom Edge (Lu)7' 1" o/c <br />Dead Roof Live <br />Vertical Loads Location (Side)Tributary Width (0.90)(non-snow: 1.25)Comments <br />0 - Self Weight (PLF)0 to 7' 1"N/A 16.0 -- <br />1 - Uniform (PSF)0 to 7' 1" (Front)10'15.0 -Ext. Wall <br />2 - Uniform (PSF)0 to 7' 1" (Front)4'15.0 20.0 Roof <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. <br />MEMBER REPORT PASSED <br />Low Roof & Floor, BM-8 <br />1 piece(s) 6 x 12 DF No.1 <br />ForteWEB Software Operator Job Notes 10/8/2023 6:53:29 PM UTC <br />Rong Lei <br />RL Engineering <br />(415) 887-8691 <br />leirongyao@gmail.com <br />ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: 23-1017 1005 S Virlee St, Santa Ana <br />Page 15 / 24 <br />Page 22 of 48 <br />1005 S Virlee St <br />Unit# 28/26/2024