My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1005 S Virlee St Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Virlee St
>
1005 S Virlee St Unit# 2
>
1005 S Virlee St Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:14:26 PM
Creation date
6/1/2025 11:52:13 AM
Metadata
Fields
Template:
Plan
Permit Number
101118024
Full Address
1005 S Virlee St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)624 @ 4' 3 1/2"3281 (1.50")Passed (19%)--1.0 D + 1.0 L (All Spans) <br />Shear (lbs)340 @ 3' 4 1/4"4725 Passed (7%)1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)643 @ 2' 2 3/4"6768 Passed (10%)1.00 1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in)0.001 @ 2' 2 3/4"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in)0.003 @ 2' 2 3/4"0.206 Passed (L/999+)--1.0 D + 1.0 L (All Spans) <br />System : Floor <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2018 <br />Design Methodology : ASD <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor Live Factored Accessories <br />1 - Stud wall - DF 3.50"3.50"1.50"362 312 674 Blocking <br />2 - Hanger on 11 1/4" DF beam 3.50"Hanger¹1.50"380 330 709 See note ¹ <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)4' 4" o/c <br />Bottom Edge (Lu)4' 4" o/c <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger LUS48 2.00"N/A 6-10dx1.5 4-10d <br />•Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />Dead Floor Live <br />Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments <br />0 - Self Weight (PLF)0 to 4' 3 1/2"N/A 10.0 -- <br />1 - Uniform (PSF)0 to 4' 7" (Front)10'10.0 -Int. Wall <br />2 - Uniform (PSF)0 to 4' 7" (Front)3' 6"15.0 40.0 Floor <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. <br />MEMBER REPORT PASSED <br />Low Roof & Floor, BM-9 <br />1 piece(s) 4 x 12 DF No.1 <br />ForteWEB Software Operator Job Notes 10/8/2023 6:53:29 PM UTC <br />Rong Lei <br />RL Engineering <br />(415) 887-8691 <br />leirongyao@gmail.com <br />ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: 23-1017 1005 S Virlee St, Santa Ana <br />Page 16 / 24 <br />Page 23 of 48 <br />1005 S Virlee St <br />Unit# 28/26/2024
The URL can be used to link to this page
Your browser does not support the video tag.