My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
106 E 4th St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
106 E Fourth St
>
106 E 4th St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:53:51 AM
Creation date
6/1/2025 11:53:45 AM
Metadata
Fields
Template:
Plan
Permit Number
20180879
101116506
Full Address
106 E Fourth St
Document Relationships
101116506 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fourth St\106 E Fourth St
20180879 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fourth St\106 E Fourth St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 11:53 AM
Modified:
5/30/2025 11:39 AM
Text:
www
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project Name: <br />George Hansen <br />Property address: <br />106 E 4th St, <br />Santa Ana, CA 92701 <br />DATE: 08/ 18/2023 <br />VICINITY MAP <br />SCALE: NTS <br />PV SOLAR SYSTEM DETAILS <br />ELECTRICAL INFORMATION: <br />EXISTING <br />MAIN SERVICE PANEL BUS SIZE: 150A <br />MAIN SERVICE BREAKER SIZE: 150A <br />MOUNTING SYSTEM: <br />BUILDING INFORMATION: <br />CONSTRUCTION TYPE: V-B <br />OCCUPANCY: M <br />ROOF: <br />SYSTEM SIZE: DC STC: 15.190 KW <br />SYSTEM SIZE: AC CEC: 10.819 KW <br />SOLAR MODULES: ( ) <br />SATELLITE VIEW <br />SCALE: NTS <br />MAIN <br />3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED <br />4. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO <br />INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING <br />COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, <br />UTILITY CO. AND CITY INSPECTORS AS NEEDED. <br />5. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF <br />SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY <br />AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. <br />6. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL <br />BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL <br />BE COORDINATED WITH OTHER TRADES. <br />7. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV <br />INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS <br />RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING <br />THE EXTRA WEIGHT. <br />8. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE <br />CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE <br />WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS <br />APPROPRIATE. <br />9. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE <br />DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED <br />BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE <br />SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF <br />THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. <br />10. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, <br />ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE <br />COMPLETION OF WORK <br />PHOTOVOLTAIC NOTES: <br />1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL <br />BE TESTED, LISTED AND IDENTIFIED BY RECOGNIZED ELECTRICAL <br />TESTING LABORATORY <br />2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL <br />VENTS <br />3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. <br />5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL <br />NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING <br />ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR <br />OUTPUT CIRCUIT GROUNDED CONDUCTORS. <br />4. SOLAR INVERTER SHALL BE LISTED TO UL1741. <br />6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND <br />WIRING SHALL BE PROTECTED FROM PHYSICAL DAMAGE. <br />7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT <br />CIRCUITS OVER 150V TO GROUND SHALL NOT BE <br />ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE <br />ENERGIZED. <br />8. INVERTER IS EQUIPED WITH INTEGRATED GFDI, THUS <br />PROVIDING GROUND FAULT PROTECTION <br />9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG <br />RATED <br />10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY. <br />11. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE <br />USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC <br />GROUNDING, AC GROUNDING AND BONDING BETWEEN <br />AC AND DC SYSTEMS. <br />12. NON-CURRENT CARRYING METAL PARTS OF <br />EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. <br />BOND BOTH ENDS OF RACEWAYS. <br />GENERAL NOTES <br />1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED <br />ELECTRICAL TESTING LABORATORY <br />CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED <br />BY THE MANUFACTURER ATTESTING TO ITS SAFETY <br />2. OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED OR BETTER <br />31 Silfab 490 Watt <br />IRONRIDGE <br />FOAM ROOF <br />INVERTERS: ( ) Enphase IQ8A Microinverters31 <br />ROOF PLAN <br />SINGLE LINE DIAGRAM <br /> ATTACHMENT LAYOUT <br />SIGNAGE <br />RSD DATA SHEET <br />INVERTER DATA SHEET <br />1 <br />INDEX <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />SITE PLAN <br />MODULE DATA SHEET <br />RACKING DATA SHEET <br />ATTACHMENT DATASHEET <br />ECB DATA SHEET11 <br />: RAFTER 2 X 10 @ 36" O.C. <br />THE INSTALLATION OF SOLAR ARRAYS AND <br />PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH <br />THE FOLLOWING CODES: <br />·2020 National Electrical Code <br />·2022 California Building Code <br />·2022 California Residential Code <br />·2022 California Green Building Standard Code <br />·2022 California Plumbing Code <br />·2022 California Mechanical Code <br />·2022 California Electrical Code <br />·2022 California Fire Code <br />·2022 California Energy Code <br />·2016 International Property Maintenance Code <br />AD ADOPTED BY THE STATE OF CALIFORNIA <br />ALL OTHER ORDINANCE ADOPTED BY THE <br />LOCAL GOVERNING AGENCIES <br />2 X 10 @ 60" O.C. <br />PEAK POWER SOLUTIONS <br />360 E 1ST STREET #947, <br />TUSTIN, CA 92780 <br />Phone: 714-258-3900 <br />License # 973253 C10 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2023-4620 Structural Only <br />August 24, 2023 <br />The scope of the plans is for the installation of the solar <br />photovoltaic system only and the approval is subject to compliance <br />with all applicable city and state codes and regulations regarding <br />construction. The approval of the plans does not constitute any <br />certification of the accuracy, completeness, or building permit <br />status of the existing buildings and structures as shown. <br />Bldg# 101116506 <br />Elec# 20180879 <br />Issued 10/10/23 <br /> <br />Approvals: <br />PLNG: FArias <br />BLDG: JLo <br />ELEC: MSmith <br />106 E 4th St - 101116506 <br />& 2018087910/10/2023
The URL can be used to link to this page
Your browser does not support the video tag.