Laserfiche WebLink
tk1sc project number: B2305501.000 <br />drawn by:checked by: <br />drawing no.: <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />pl <br />a <br />n <br />n <br />i <br />n <br />g <br />in <br />t <br />e <br />r <br />i <br />o <br />r <br />s <br />tB <br />P <br />/ <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />46 <br />1 <br />1 <br /> <br />T <br />e <br />l <br />l <br />e <br />r <br /> <br />A <br />v <br />e <br />n <br />u <br />e <br />Ne <br />w <br />p <br />o <br />r <br />t <br /> <br />B <br />e <br />a <br />c <br />h <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />6 <br />0 <br />ph <br />: <br /> <br />9 <br />4 <br />9 <br />. <br />6 <br />7 <br />3 <br />. <br />0 <br />3 <br />0 <br />0 <br />consultant <br />agency <br />owner <br />date: <br />drawing title: <br />description:date:Rev: <br />tBP project number : <br />architect <br />THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER INFORMATION <br />CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK OF tBP/ARCHITECTURE AND <br />SHALL REMAIN THE PROPERTY OF tBP/ARCHITECTURE IN PERPETUITY. NO PART <br />THEREOF SHALL BE REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR <br />OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS WRITTEN CONSENT <br />OF tBP/ARCHITECTURE. <br />ph: 714.667.2700 <br />SANTA ANA, CA 92701 <br />20 CIVIC CENTER PLAZA <br />SANTA ANA PLANNING AND BUILDING AGENCY <br /># <br />DA <br />N <br />C <br />E <br /> <br />S <br />T <br />U <br />D <br />I <br />O <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />09/06/2023 <br />11870 Pierce Street, Suite 160 <br />Riverside, California 92505 <br />951.299.4160 www.tk1sc.com <br />Project Leader - Bill Voller <br />tk1sc Job #: B2305501.000 <br />Electrical Lead - Marie Rothenberger <br />City Submittal 09/06/23- <br />FIRE ALARM <br />FA0-0 <br />ALARM SIGNALING CIRCUITS. <br />MANUAL FIRE PULL STATIONS. <br />REMOTE ANNUNCIATE. <br />MANUAL STATIONS: FURNISH AND INSTALL WHERE INDICATED ON DRAWINGS OR AS REQUIRED BY LOCAL AH. DEVICE SHALL BE <br />ADDRESSABLE UNLESS OTHERWISE NOTED. STATION SHALL BE KEYED ALIKE AS THE CONTROL PANEL. <br />SMOKE AND HEAT DETECTORS - INCLUDING THOSE REQUIRED UNDER OTHER SECTIONS. <br />THE UDACT SHALL BE CAPABLE OF TRANSMITTING EVENTS IN AT LEAST NINE DIFFERENT FORMATS. THIS ENSURES <br />COMPATIBILITY WITH EXISTING AND FUTURE TRANSMISSION FORMATS. ACCEPTED FORMATS INCLUDE 3+1 STANDARD, 4+1 <br />STANDARD, DECO CONTACT ID OR 4+1 AND 4+2 DECO.QUALITY ASSURANCE: WORK SHALL BE PERFORMED BY A QUALIFIED SYSTEMS CONTRACTOR HOLDING A <br />C-10 LICENSE. <br />4. <br />ACCEPTANCE TESTING: FINAL ACCEPTANCE WILL BE GIVEN AFTER SUCCESSFUL ACCEPTANCE TESTING AND <br />SUBMISSION OF APPROVED AS-BUILT DOCUMENTATION AND OPERATION AND MAINTENANCE MANUALS. <br />ACCEPTANCE TESTING OF FIRE DETECTION SYSTEM SHALL BE AS REQUIRED BY THE STATE FIRE MARSHAL AND <br />LOCAL AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING REQUIRED <br />TESTING, COORDINATING SCHEDULING, AND CONDUCTING TEST NECESSARY TO ACHIEVE OCCUPANCY <br />CERTIFICATION. TESTS SHALL INCLUDE THE FOLLOWING: <br />ZONING: THE BUILDING SHALL BE DIVIDED INTO ZONES FOR ALARM ANNUNCIATION AND SYSTEM CONFIGURATION <br />PER THE REQUIREMENTS OF THE LOCAL FIRE MARSHAL AND/OR AUTHORITY. A ZONE WILL BE ASSIGNED FOR <br />EACH SPRINKLER FLOW SWITCH AND EACH TAMPER SWITCH. AIR-HANDLING SYSTEMS REQUIRING IN-DUCT <br />DETECTION SHALL BE ZONED PER UNIT. UNIT SHALL BE SHUT DOWN DIRECTLY BY AUXILIARY RELAY CONTROLLED <br />BY DUCT SMOKE DETECTOR. <br />PROOF THAT THE FIRE ALARM CONTRACTOR IS UNDERWRITERS LABORATORIES, INC. (U.L.) LISTED UNDER <br />THE CLASSIFICATION OF "PROTECTIVE SIGNALING SERVICES- LOCAL, AUXILIARY, REMOTE STATION AND <br />PROPRIETARY (UUJS) AND CENTRAL STATION PROTECTIVE SIGNALING SERVICES (UUFX)." <br />OPERATION OF SYSTEM ON STANDBY POWER WITH PRIMARY POWER OFF. <br />NFPA 72, CHAPTER 7, INSPECTION TESTING AND MAINTENANCE COMPLETE THE INSPECTION AND TESTING FORM IN <br />ITS ENTIRETY. SUBMIT A COPY TO THE OWNER, ARCHITECT AND FIRE AUTHORITY. <br />FIRE ALARM SYSTEM SCHEMATIC <br />B. <br />A. <br />PART II - EXECUTION <br />CERTIFICATION OF INSTALLATION COMPANY: <br />AN OPERATION OF EACH INITIATING DEVICE. <br />OPERATION OF SUPERVISORY FEATURES OF SYSTEM. <br />AN OPERATION OF EACH INDICATING DEVICE (ALARM, HORN, AND ALARM LAMP). <br />OPERATION OF ALL FEATURES OF SYSTEM UNDER NORMAL OPERATION. <br />COPY OF THE FOLLOWING (NICET) CERTIFICATES. PROOF THAT THE CERTIFICATE HOLDERS ARE A PART OF <br />THE FIRE ALARM CONTRACTOR'S LOCAL FACILITY SERVICING THIS PROJECT AND WILL INSTALL THE FIRE <br />ALARM SYSTEM. NON-NICET INSTALLERS MAY BE UTILIZED ON THE PROJECT TO ASSIST NICET-CERTIFIED <br />INSTALLER ONLY IF DIRECTLY SUPERVISED BY NICET-CERTIFIED INSTALLER. THE RATIO OF <br />NICET-TO-NON-NICET INSTALLERS SHALL NOT EXCEED 1:3. <br />CERTIFIED NICET TECHNICIAN LEVEL 2 (INSTALLER). <br />CERTIFIED NICET TECHNICIAN LEVEL 4 (SUPERVISOR)2. <br />1. <br />THE UDACT SHALL INCLUDE INDEPENDENT ZONE/POINT REPORTING IN THE CONTACT ID FORMAT. IN THIS FORMAT THE UDACT <br />SHALL SUPPORT TRANSMISSION OF UP TO 2,040 POINTS. THIS ENABLES THE CENTRAL STATION TO HAVE EXACT DETAILS <br />CONCERNING THE ORIGIN OF THE FIRE OR RESPONSE EMERGENCY. <br />ABNORMAL TEST SIGNAL (PER URL REQUIREMENTS) <br />EIA-485 COMMUNICATIONS FAILURE <br />INDEPENDENT ZONE (ALARM, TROUBLE, NON-ALARM) <br />INDEPENDENT ZONE SUPERVISORY SIGNAL <br />AC (MAINS) POWER LOSS <br />LOW BATTERY AND EARTH FAULT <br />12 AND 24 HOUR TEST SIGNAL <br />COMMUNICATION SHALL INCLUDE VITAL SYSTEM STATUS SUCH AS: <br />6. <br />5. <br />SYSTEM OFF NORMAL <br />MANUAL STATIONS SHALL BE DUAL ACTION WITH A KEYED RESET. KEY SHALL MATCH THE CONTROL PANEL. <br />STATIONS SHALL BE ADA 5 LB. PULL FORCE APPROVED. <br />DESIGN REQUIREMENTS: THE FIRE ALARM SYSTEM SHALL BE RESPONSIBLE FOR CONTINUALLY SUPERVISING AND <br />MONITORING BY ZONE THE FOLLOWING INITIATING, SIGNALING AND MONITORING CIRCUITS (AT A MINIMUM): <br />THE COMPLETE INSTALLATION SHALL CONFORM TO APPLICABLE SECTIONS OF NFPA-72 2016 EDITION OR LATEST <br />ADOPTED VERSION, LOCAL CODE REQUIREMENTS AND NATIONAL ELECTRICAL CODE. <br />CONTROL PANEL SHALL BE FIELD PROGRAMMABLE WITHOUT THE USE OF A LAP TOP COMPUTER OR OTHER <br />SPECIAL INSTRUMENTS. <br />ALL AUDIO VISUAL DEVICES SHALL BE MANUFACTURER'S STANDARD WHITE UNLESS OTHERWISE NOTED. ALL <br />VISUAL DEVICES WITHIN THE SAME AREA SHALL BE SYNCHRONIZED. <br />CONTROL PANEL SHALL EMPLOY AUTOMATIC DRIFT COMPENSATION OF SMOKE DETECTORS. CONTROL PANEL <br />SHALL MEET THE REQUIREMENTS OF NAPA CHAPTER 7 FOR CALIBRATED TEST. <br />PART 1 - GENERAL REQUIREMENTS <br />FIRE ALARM SYSTEM POWER SUPPLY (FAPS): THE FAPS IS A DEVICE DESIGNED FOR USE AS EITHER A REMOTE 24 VOLT POWER <br />SUPPLY OR USED TO POWER NOTIFICATION APPLIANCES. THE FAPS SHALL OFFER UP TO 6.0 AMPS (4.0 AMPS CONTINUOUS) OF <br />REGULATED 24 VOLT POWER. IT SHALL INCLUDE AN INTEGRAL CHARGER DESIGNED TO CHARGE 7.0 AMP HOUR BATTERIES AND TO <br />SUPPORT 60 HOUR STANDBY. THE FAPS SHALL HAVE TWO INPUT TRIGGERS. THE INPUT TRIGGER SHALL BE A NOTIFICATION <br />APPLIANCE CIRCUIT (FROM THE FIRE ALARM CONTROL PANEL) OR A RELAY. FOUR OUTPUTS (TWO STYLE Y OR Z AND TWO STYLE Y) <br />SHALL BE AVAILABLE FOR CONNECTION TO THE NOTIFICATION DEVICES. THE FAPS SHALL INCLUDE THE ABILITY TO DELAY THE AC <br />FAIL DELAY PER NFPA REQUIREMENTS. <br />THE UDACT SHALL BE COMPLETELY FIELD PROGRAMMABLE FROM A BUILT-IN KEYPAD AND FOUR-CHARACTER RED, <br />SEVEN-SEGMENT DISPLAY. <br />THE UDACT SHALL INCLUDE CONNECTIONS FOR DUAL TELEPHONE LINES (WITH VOLTAGE DETECT), PER U.L./NFPA <br />REQUIREMENTS. IT SHALL INCLUDE THE ABILITY FOR SPLIT REPORTING OF PANEL EVENTS. <br />THE UDACT SHALL BE COMPACT IN SIZE, MOUNTING IN A STANDARD MODULE POSITION OF THE FIRE ALARM CONTROL CABINET. <br />THE CONNECTION BETWEEN THE UDACT AND THE CONTROL PANEL SHALL BE COMPLETELY SUPERVISED. <br />UNIVERSAL DIGITAL ALARM COMMUNICATOR TRANSMITTER (UDACT): THE UDACT IS AN INTERFACE FOR COMMUNICATING DIGITAL <br />INFORMATION BETWEEN A FIRE ALARM CONTROL PANEL AND A URL LISTED CENTRAL STATION. <br />MONITOR MODULE: MONITOR RELAYS FOR MONITORING SMOKE DOORS, GENERATORS, AUTOMATIC TRANSFER SWITCHES, FIRE <br />SUPPRESSION SYSTEMS, ETC. AND WHERE INDICATED ON THE DRAWINGS OR AS REQUIRED BY LOCAL AH. <br />TAMPER SWITCHES: SPRINKLER VALVE TAMPER SWITCHES COVER REMOVAL SHALL BE SUPERVISED. SWITCH SHALL BE PROVIDED <br />WITH EITHER ONE OR TWO SETS OF S.P.D.T. MICRO SWITCHES AS REQUIRED. TAMPER SWITCH SHALL BE URL LISTED FOR ITS <br />INTENDED PURPOSE. DEVICE TO BE FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. <br />WATERFLOW SWITCHES: WATERFLOW SWITCHES SHALL BE PROVIDED WITH A TAPPED 1/2" CONDUIT CONNECTION. THE FLOW <br />SWITCH SHALL BE U.L. LISTED FOR ITS INTENDED PURPOSE. DEVICE TO BE FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. <br />SPRINKLER BELL: PROVIDE WHERE INDICATED ON DRAWINGS OR AS REQUIRED BY LOCAL AH. INCLUDE ALL COSTS IN BASE BID TO <br />PROVIDE AND INSTALL A FLUSH HORN OR BELL PER THE EXTERIOR FLUSH HORN DETAIL. AN EXPOSED EXTERIOR BELL OR HORN IS <br />NOT ACCEPTABLE UNLESS ITS USE IS DIRECTED BY THE LOCAL FIRE MARSHAL. THE FIRE ALARM CONTRACTOR SHALL NOTIFY THE <br />ARCHITECT OF THE USE OF SURFACE MOUNTED BELLS/HORNS PRIOR TO ROUGH-IN. <br />MAGNETIC DOOR HOLDER: PROVIDE WHERE INDICATED ON DRAWINGS OR AS REQUIRED BY LOCAL AH. <br />CONTROL MODULE: PROVIDE WHERE INDICATED ON DRAWINGS OR AS REQUIRED BY LOCAL AH. <br />2. <br />3. <br />1. <br />EQUIPMENT SUBSTITUTIONS MUST BE PRE-APPROVED BY THE ELECTRICAL ENGINEER (10) DAYS PRIOR TO THE BID DATE. <br />CONTRACTOR MUST SHOW OPERATION OF EQUIPMENT AND COMPLIANCE WITH ALL FUNCTIONS AND FEATURES SPECIFIED. <br />EQUIPMENT SUBSTITUTIONS NOT PRE-APPROVED PRIOR TO BID DATE WILL BE REJECTED. <br />PART III - PRODUCTS (FACP) <br />SPEAKER/STROBE: SPEAKER/STROBE DEVICES SHALL BE WALL OR CEILING MOUNTED PER THE DRAWINGS OR AS REQUIRED BY <br />LOCAL AH. SPEAKER/STROBE SHALL OPERATE ON 24 VC POLARIZED CIRCUIT AND SHALL BE PROVIDED WITH A SEMI-FLUSH <br />MOUNTING PLATE. STROBE LIGHT SHALL BE WHITE LEAN WITH "FIRE" ON (2) SIDES. SPEAKER SHALL HAVE DUAL VOLTAGE <br />CAPABILITY AND FIELD SELECTABLE TAPS ADJUSTABLE FROM 1/8 TO 8 WATTS. THE STROBE SHALL HAVE A CANDELA <br />DISTRIBUTION/RATING TO MEET ADA REQUIREMENTS. <br />SPEAKER: SPEAKER DEVICES SHALL BE WALL OR CEILING MOUNTED PER THE DRAWINGS. SPEAKER SHALL OPERATE ON 24 VC <br />POLARIZED CIRCUIT AND SHALL BE PROVIDED WITH A SEMI-FLUSH MOUNTING PLATE. SPEAKER SHALL HAVE DUAL VOLTAGE <br />CAPABILITY AND FIELD SELECTABLE TAPS ADJUSTABLE FROM 1/8 TO 8 WATTS. <br />VOICE EVACUATION PANEL (VEC): THE VC IS SELF-CONTAINED A.V. POWER SUPPLY/TRANSPONDER FOR USE WITH DISTRIBUTED <br />MULTI CHANNEL VOICE SYSTEMS CAPABLE OF UP TO FOUR SIMULTANEOUS MESSAGES (MINIMUM OF EIGHT WHEN USED AS PART OF <br />A MASS NOTIFICATION SYSTEM). IT CONTAINS AN INTEGRATED AUDIO AMPLIFICATION AND DISTRIBUTION SUB SYSTEM CONTROLLED <br />BY THE FLAP. THE TRANSPONDER SHALL BE CAPABLE OF PLAYING UP TO FOUR SIMULTANEOUS MESSAGES OVER (4) INTEGRATED, <br />CONTINUOUSLY SUPERVISED SPEAKER CIRCUITS. A FIREMAN'S MICROPHONE WITH ALL-CALL LOCAL PAGE CAPABILITY SHALL BE <br />PROVIDED. <br />ANNUNCIATOR/NETWORK SYSTEM ANNUNCIATOR: WHERE INDICATED ON DRAWINGS, PROVIDE AND INSTALL A CHARACTER DISPLAY <br />REMOTE ANNUNCIATOR. REMOTE ANNUNCIATOR SHALL BE ELECTRICALLY SUPERVISED FROM CONTROL PANEL. REMOTE <br />ANNUNCIATOR SHALL BE INSTALLED IN A FLUSH OR SURFACE MOUNTED CABINET WITH HINGED DOOR AND LOCK. COORDINATE FINAL <br />LOCATION OF ALL ANUNNCIATORS WITH THE ARCHITECT AND LOCAL AHJ PRIOR TO ROUGH-IN. <br />SMOKE DETECTORS: FURNISH AND INSTALL WHERE INDICATED ON DRAWINGS OR AS REQUIRED BY LOCAL AHJ. SENSORS SHALL BE <br />ANALOG ADDRESSABLE TYPE. <br />BEAM DETECTORS: BEAM DETECTORS SHALL BE REFLECTIVE TRANSMITTER/RECEIVER TYPE WITH INTEGRAL SENSITIVITY <br />TRANSMITTING AN INFRARED SIGNAL TO A REFLECTIVE SURFACE OR RECEIVER. THE BEAM DETECTOR SHALL HAVE A KEYED <br />REMOTE TEST AND ALARM INDICATOR MOUNTED WITHIN 100 FEET OF THE BEAM DETECTOR. FINAL LOCATION TO BE DETERMINED BY <br />ARCHITECT. THE BEAM DETECTOR SHALL HAVE AN INTEGRAL OPTICS ALIGNMENT (TOOL) BUILT IN THE TRANSMITTER. AN <br />ADDRESSABLE, (4) WIRE MONITORING MODULE SHALL COMMUNICATE THE ALARM AND TROUBLE INDICATIONS OF THE BEAM <br />DETECTOR BACK TO THE FIRE ALARM CONTROL PANEL OR TRANSPONDER. <br />HORN/STROBE: HORN/STROBE DEVICES SHALL BE WALL OR CEILING MOUNTED PER DRAWINGS OR AS REQUIRED BY LOCAL AHJ. <br />SOUNDER/STROBE SHALL OPERATE ON 24 VDC POLARIZED CIRCUIT AND SHALL BE PROVIDED WITH A SEMI-FLUSH MOUNTING PLATE. <br />STROBE LIGHT SHALL BE WHITE LEXAN WITH "FIRE" ON (2) SIDES. HORN SHALL HAVE A MINIMUM SOUND OUTPUT OF 100 DB AT 10'-0". <br />THE STROBE SHALL HAVE A CANDELA DISTRIBUTION/RATING TO MEET ADA REQUIREMENTS. <br />INSTALLATION OF THE FIRE ALARM SYSTEM SHALL NOT BE STARTED UNTIL DRAWINGS, INCLUDING STATE FIRE <br />MARSHAL LISTING NUMBERS OF FIRE ALARM COMPONENTS, ARE SUBMITTED TO AND APPROVED BY THE LOCAL <br />FIRE MARSHAL. WRITTEN CERTIFICATION BY FIRE ALARM EQUIPMENT DISTRIBUTOR OR MANUFACTURER SHALL <br />BE SUBMITTED TO THE ARCHITECT AND THE STATE FIRE MARSHAL STATING THAT THE NEW SYSTEM AND ITS <br />COMPONENT PARTS ARE AS "APPROVED AND LISTED" BY THE STATE FIRE MARSHAL AND THAT INSTALLATION <br />CONFORMS IN ALL RESPECTS TO REQUIREMENTS SET FORTH IN ARTICLE 72, TITLE 24, PART 2, CALIFORNIA CODE <br />OF REGULATIONS. FIRE ALARM SYSTEM CONSTRUCTION SHALL NOT BE STARTED UNTIL FIRE ALARM DRAWINGS <br />ARE APPROVED BY AHJ AND ENGINEER. <br />REMOTE LED: PROVIDE REMOTE LED AND/OR REMOTE LED/TEST STATION WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY LOCAL <br />AHJ. DEVICE LOCATION SHALL BE COORDINATED WITH LOCAL AHJ AND ARCHITECT PRIOR TO ROUGH-IN. <br />(FOR HVAC, SHUTOFF, SMOKE FIRE DAMPER CONTROL, ETC.) <br />GENERAL: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE FURNISHING OF ALL FINAL DESIGN, AGENCY <br />APPROVALS, PLAN CHECK FEES, LABOR, EQUIPMENT, MATERIALS, AND PERFORMANCE OF OPERATIONS IN <br />CONNECTION WITH THE INSTALLATION OF A COMPLETE AND FULLY FUNCTIONING CODE APPROVED FIRE ALARM <br />SYSTEM. <br />IT IS THE INTENT OF THE CONTRACT DOCUMENTS, WHICH ARE PRESENTED IN A DIAGRAMMATIC, "DESIGN-BUILD" <br />FORMAT, FOR THE CONTRACTOR TO DESIGN, PROVIDE AND INSTALL A COMPLETE AND FULLY FUNCTIONING, CODE <br />APPROVED FIRE ALARM SYSTEM. IN THE EVENT THAT ADDITIONAL DETAILS OR SPECIAL CONSTRUCTION IS <br />REQUIRED FOR WORK INDICATED OR SPECIFIED IN THIS SECTION OR WORK SPECIFIED IN OTHER SECTIONS, IT <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIAL AND EQUIPMENT WHICH IS <br />USUALLY FURNISHED WITH SUCH SYSTEMS, IN ORDER TO PROVIDE A COMPLETE AND FULLY FUNCTIONING <br />INSTALLATION, WHETHER MENTIONED HEREIN OR NOT. <br />SPRINKLER FLOW / TAMPER SWITCHES - INCLUDING THOSE IN OTHER SECTIONS. <br />PIV / OS&Y DEVICES - INCLUDING THOSE INSTALLED IN OTHER SECTIONS. <br />REQUIRED APPROVALS: THE FIRE ALARM SYSTEM SHALL BE APPROVED BY THE LOCAL FIRE AUTHORITY IN <br />ADDITION TO ANY OTHER REQUIRED APPROVALS. THIS APPROVAL SHALL BE OBTAINED PRIOR TO THE SUBMITTAL <br />OF SHOP DRAWING DOCUMENTATION TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. <br />SYSTEM PERFORMANCE: FURNISH AND INSTALL A COMPLETE FIRE ALARM SYSTEM AS DESCRIBED HEREIN AND <br />AS INDICATED ON DRAWINGS TO BE WIRED, CONNECTED, AND LEFT IN FIRST CLASS OPERATING CONDITION. <br />SYSTEM SHALL USE CLOSED LOOP INITIATING DEVICE CIRCUITS WITH INDIVIDUAL ZONE SUPERVISION, INDIVIDUAL <br />INDICATING APPLIANCE CIRCUIT SUPERVISION, INCOMING AND STANDBY POWER SUPERVISION. INCLUDE A <br />CONTROL PANEL, MANUAL PULL STATIONS, AUTOMATIC FIRE DETECTORS, HORNS, BELLS, FLASHING LIGHTS, <br />ANNUNCIATOR, ALL WIRING, CONNECTIONS TO DEVICES, OUTLET BOXES, JUNCTION BOXES, AND ALL OTHER <br />NECESSARY MATERIAL FOR A COMPLETE OPERATING SYSTEM. <br />WARRANTY: CONTRACTOR SHALL WARRANT COMPLETED FIRE ALARM SYSTEM WIRING AND EQUIPMENT TO BE <br />FREE FROM INHERENT MECHANICAL AND ELECTRICAL DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF <br />COMPLETION AND CERTIFIED TEST, OR FROM DATE OF FIRST BENEFICIAL USE. THE EQUIPMENT MANUFACTURER <br />SHALL MAKE AVAILABLE TO THE OWNER A MAINTENANCE CONTRACT PROPOSAL TO PROVIDE A MINIMUM OF (2) <br />INSPECTIONS AND TESTS PER YEAR IN COMPLIANCE WITH NFPA-72 GUIDELINES. <br />UPON COMPLETION OF INSTALLATION OF FIRE ALARM EQUIPMENT, ELECTRICAL CONTRACTOR SHALL PROVIDE TO <br />THE ENGINEER A SIGNED, WRITTEN STATEMENT CONFIRMING THAT THE FIRE ALARM EQUIPMENT WAS INSTALLED <br />IN ACCORDANCE WITH SPECIFICATIONS, WIRING DIAGRAMS, INSTRUCTIONS AND DIRECTIONS PROVIDED BY <br />MANUFACTURER. A COMPLETE DESCRIPTION OF NATURE AND SCOPE OF TRAINING PROGRAM FOR MAINTENANCE <br />TECHNICIANS, OPERATORS, SYSTEM USERS, AND MANAGEMENT PERSONNEL SHALL BE PROVIDED. CONTRACTOR <br />SHALL PROVIDE A COMPLETE TRAINING PROGRAM FOR SYSTEM USERS, AND A MINIMUM OF (4) COPIES OF <br />OPERATING INSTRUCTIONS. IN ADDITION, CONTRACTOR SHALL PROVIDE A TRAINING PROGRAM FOR THE <br />OWNER'S MAINTENANCE PERSONNEL. THIS TRAINING SHALL BE PROVIDED FOR A MINIMUM OF (3) PERSONS <br />WITHIN ONE YEAR OF COMPLETION DATE. COSTS FOR INSTRUCTION SHALL BE PAID BY CONTRACTOR. TRAINING <br />SHALL BE SCHEDULED AND COORDINATED BY THE OWNER. <br />FIRE ALARM EQUIPMENT SHALL BE U.L. LISTED AND C.S.F.M. LISTED. CATALOG AND MODEL NUMBERS LISTED ARE INTENDED TO <br />ESTABLISH TYPE AND QUALITY OF EQUIPMENT AND SYSTEM DESIGN AS WELL AS OPERATING FEATURES REQUIRED. <br />MANUFACTURER'S SPECIFICATION SHEETS OF EACH ITEM SO LISTED SHALL BE CONSIDERED TO BE A PART OF THESE <br />SPECIFICATIONS AND BINDING HEREIN. ANY DEVIATION FROM INTENDED FUNCTIONS OF SYSTEM SPECIFIED MAY NOT BE APPROVED, <br />AT OPTION OF THE OWNER/ENGINEER. <br />FIRE ALARM CONTROL PANEL (FACP): WHERE INDICATED ON DRAWINGS, PROVIDE AND INSTALL A FIRE ALARM CONTROL PANEL. <br />CONSTRUCTION SHALL BE MODULAR WITH SOLID STATE, MICROPROCESSOR-BASED ELECTRONICS. <br />FATC: PROVIDE FIRE ALARM TERMINAL CABINET AS REQUIRED OR AS SHOWN ON DRAWINGS. <br />PROVIDE ALL NECESSARY CONDUIT(S) AND CONDUCTORS AS REQUIRED TO CONNECT DEVICES REQUIRED TO BE <br />MONITORED BY THE LOCAL AUTHORITY HAVING JURISDICTION. THESE INCLUDE, BUT ARE NOT LIMITED TO, PIV(S), <br />BACKFLOW PREVENTER(S), DETECTOR CHECK VALVE(S), OS&Y VALVE(S), ETC. REFER TO CIVIL/PLUMBING <br />DRAWINGS FOR EXACT LOCATIONS AND QUANTITIES OF THESE DEVICES. <br />HEAT DETECTORS: FURNISH AND INSTALL WHERE INDICATED ON DRAWINGS OR AS REQUIRED BY LOCAL AHJ. SENSORS SHALL BE <br />ADDRESSABLE. <br />DUCT SMOKE DETECTORS: PROVIDE DUCT SMOKE DETECTORS WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY LOCAL AHJ. <br />DUCT SMOKE DETECTORS SHALL BE PHOTOELECTRIC TYPE AND THE INSTALLATION MUST COMPLY WITH NFPA-90A. <br />7. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />ALL SYSTEM EXTENSIONS AND FINAL CONNECTIONS TO THE EXISTING FIRE ALARM (FA) OR CENTRAL <br />MONITORING (CM) SYSTEM SHALL BE MADE BY THE CONTRACTOR INCLUDING FINAL TESTING AND <br />COORDINATION WITH THE FIRE MARSHALL AND BUILDING OWNER'S SECURITY DEPARTMENT. CONTRACTOR IS <br />RESPONSIBLE FOR PRE-BID FIELD INVESTIGATION OF EXISTING FIRE ALARM (FA) OR CENTRAL MONITORING <br />(CM) SYSTEM. <br />THE CONTRACTOR SHALL COORDINATE THE LOGISTICS AND WORK IMPLEMENTATION WITH THE BUILDING <br />OWNER, BUILDING OWNER'S SECURITY STAFF, ALARM MONITORING COMPANY BEFORE STARTING ANY WORK. <br />EVERY SURPLUS FA/CM DEVICE, RESULTING FROM THIS PROJECT, SHALL BE TURNED OVER TO THE BUILDING <br />OWNER. <br />THE CONTRACTOR SHALL DETERMINE THE EXTENT OF THEIR WORK INCLUDING, BUT NOT LIMITED TO, SUCH <br />ITEMS AS CONDUITS, WIRES, "J" BOXES, ETC. THE ACTUAL FINAL CONNECTIONS OF ALL FA/CM DEVICES <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />TO PRECLUDE EXISTING FA/CM SMOKE DETECTOR ACTIVATION DUE TO THE PROXIMITY OF ANY DEMOLITION <br />OR CONSTRUCTION RELATED ACTIVITIES, THE CONTRACTOR SHALL, WHEN WORKING IN THE PROXIMITY OF <br />ANY SENSOR, REQUEST THAT BUILDING OWNER'S ALARM MONITORING COMPANY PUT THE SYSTEM OFF LINE. <br />ON AND OFF LINE ACTIVATION OF THE SYSTEM SHALL BE THOROUGHLY COORDINATED WITH THE BUILDING <br />OWNER. THERE IS A $2,000 PENALTY, ENFORCED BY AND PAID TO THE BUILDING OWNER, FOR EACH <br />OCCURRENCE OF A FALSE ALARM CAUSED BY THE NEGLIGENCE OF CONSTRUCTION ACTIVITIES. <br />COORDINATE ALL SMOKE DETECTOR PROTECTION WITH BUILDING OWNER'S ALARM MONITORING COMPANY <br />TO PREVENT ACTIVATION OF FALSE ALARMS WHEN PUT BACK ON LINE. <br />COORDINATE AND SECURE APPROVAL FROM BUILDING OWNER PRIOR TO THE START OF NOISY <br />CONSTRUCTION ACTIVITIES TO PREVENT COMPLAINTS FROM ADJACENT TENANT SUITES. <br />ALL ROUGH ELECTRICAL, CONDUITS, "J" BOXES AND WIRING SHALL BE FURNISHED AND INSTALLED BY THE <br />CONTRACTOR. <br />ALL INITIAL DISCONNECTION/ DEMOLITION OR FINAL CONNECTION TO THE FA/CM SYSTEM SHALL BE MADE BY <br />CONTRACTOR, INCLUDING FINAL TESTING AND COORDINATION WITH THE FIRE MARSHAL AND OWNER'S <br />ALARM MONITORING COMPANY. IN ESSENCE, THE CONTRACTOR IS RESPONSIBLE FOR ALL THE WORK AND <br />MATERIALS FURNISHED AND INSTALLED BY THEM IN FULL COORDINATION WITH OWNER IN ORDER TO <br />FURNISH A FULLY OPERATIONAL SYSTEM. <br />SMOKE DETECTORS SHALL BE PROTECTED/PROVIDED IN ACCORDANCE WITH CURRENTLY ADOPTED NFPA 72 <br />STANDARD (17.7.1.11.2 &.3) AND LOCAL AHJ REQUIREMENTS FOR SMOKE DETECTION DURING CONSTRUCTION. <br />EXISTING SYSTEM EXTENSION REQUIREMENTS <br />RELAY MODULE: PROVIDE WHERE INDICATED ON DRAWINGS OR AS REQUIRED BY LOCAL AHJ. RELAY(S) SHALL BE RATED FOR <br />CONTINUOUS MOTOR OR INDUCTIVE LOADS SUCH AS COMBINATION SMOKE FIRE DAMPERS (CSFDs), MAGNETIC HOLD OPENS, ETC. <br />QUANTITY OF RELAYS SHALL BE BASED ON PROJECT-SPECIFIC CSFD LOADS WHICH SHALL NOT EXCEED 80% OF MOTOR LOAD RATING <br />OF THE RELAY. INCLUDE ALL COSTS IN BASE BID TO ADD ADDITIONAL 120V CONDUCTORS AS REQUIRED TO PARTITION LOADS ON <br />INDIVIDUAL RELAYS TO MEET THE 80% RELAY MOTOR LOAD LIMIT. <br />FIRE ALARM/CENTRAL MONITORING SYSTEM SYMBOLS <br />FA <br />FIRE ALARM CONTROL PANEL - SEE SPECIFICATIONS. <br />FIRE ALARM ANNUNCIATOR PANEL - SEE SPECIFICATIONS. <br />FIRE ALARM TERMINAL CABINET - SEE SPECIFICATIONS. <br />FIRE ALARM SYSTEM POWER SUPPLY/TRANSPONDER PANEL - SEE SPECIFICATIONS. <br />FIRE ALARM FLASHING LIGHT (ADA APPROVED), WALL MOUNTED - SEE SPECIFICATIONS. CANDELA <br />RATING AS REQUIRED TO MEET ADA COVERAGE REQUIREMENTS. <br />FIRE ALARM FLASHING LIGHT (ADA APPROVED), CEILING MOUNTED DEVICE - SEE SPECIFICATIONS. <br />CANDELA RATING AS REQUIRED TO MEET ADA COVERAGE REQUIREMENTS. <br />FIRE ALARM SPEAKER/FLASHING LIGHT, WALL MOUNTED - SEE SPECIFICATIONS. <br />FIRE ALARM SPEAKER/FLASHING LIGHT, CEILING MOUNTED DEVICE - SEE SPECIFICATIONS. <br />FIRE ALARM SPEAKER, CEILING MOUNTED - SEE SPECIFICATIONS. <br />FIRE ALARM SPEAKER, WALL MOUNTED - SEE SPECIFICATIONS. <br />FIRE ALARM BELL - SEE SPECIFICATIONS. <br />FIRE ALARM MANUAL PULL STATION, WALL MOUNTED - SEE SPECIFICATIONS. <br />FIRE ALARM SMOKE DETECTOR, CEILING MOUNTED - SEE SPECIFICATIONS. <br />FIRE ALARM HEAT DETECTOR, CEILING MOUNTED - SEE SPECIFICATIONS. <br />FIRE ALARM FLOW SWITCH - SEE SPECIFICATIONS. <br />FIRE ALARM TAMPER SWITCH - SEE SPECIFICATIONS. <br />FIRE ALARM POST INDICATING VALVE/OS&Y/DOUBLE BACK CHECK VALVE - SEE SPECIFICATIONS. <br />FIRE ALARM SYSTEM MONITOR MODULE - SEE SPECIFICATIONS. <br />FIRE ALARM SYSTEM CONTROL MODULE - SEE SPECIFICATIONS. <br />CA FIRE MARSHAL-LISTED FIRE ALARM RELAY - SEE SPECIFICATIONS. <br />FIRE ALARM BRANCH CIRCUIT PER FIRE ALARM WIRING DIAGRAMS & SPECIFICATIONS. <br />FIRE ALARM END-OF-LINE RESISTOR - SEE SPECIFICATIONS. <br />FIRE ALARM VOICE EVACUATION SYSTEM CONTROL PANEL - SEE SPECIFICATIONS. <br />FIRE ALARM SYSTEM CONTROL RELAY MODULE - SEE SPECIFICATIONS. <br />SYSTEM CONTROLS SHALL BE U.L. LISTED FOR POWER LIMITED APPLICATIONS PER NEC (OR CEC WHERE <br />ADOPTED) ART. 760.121. SYSTEM SHALL BE CAPABLE OF COMMUNICATING WITH AN OFFICE SITE CENTRAL <br />MONITORING SYSTEM. <br />C. <br />SUBMITTALS: SUBMIT IN ACCORDANCE WITH PROJECT GENERAL REQUIREMENTS SPECIFICATIONS. SHOW <br />EQUIPMENT LOCATIONS, WIRING SCHEMATICS, DETAILS, PANEL CONFIGURATION AND SIZES AND A <br />POINT-TO-POINT SCHEMATICS OF CIRCUITS AND ZONE SCHEDULES. INCLUDE FRONT ELEVATIONS, CABINET <br />DIMENSIONS, TYPE OF MOUNTING, DOORS, BARRIERS, CATALOG NUMBER OF LOCKS, AND FINISHES FOR ALL <br />TERMINAL CABINETS. SHOW INTERFACES TO EQUIPMENT FURNISHED BY OTHERS, IDENTIFYING NUMBERS OF <br />WIRES AND TERMINATION REQUIREMENTS. PROVIDE MANUFACTURER CUT SHEETS FOR ALL SYSTEM <br />COMPONENTS INDICATING U.L. AND CSFM LISTINGS. GENERIC CUT SHEETS ARE UNACCEPTABLE - EACH CUT <br />SHEET SHALL INDICATE/IDENTIFY SPECIFIC COMPONENTS ALONG WITH ANY REQUIRED COMPONENT <br />OPTIONS/ACCESSORIES UTILIZED ON THE PROJECT. PROVIDE COMPLETE SEQUENCE OF OPERATIONS OF <br />SYSTEM. PROVIDE COMPLETE SYSTEM WIRING DIAGRAMS FOR COMPONENTS CONNECTED TO SYSTEM AND <br />INTERFACES TO EXISTING EQUIPMENT. PROVIDE A COPY OF ANY STATE OR LOCAL FIRE ALARM SYSTEM <br />EQUIPMENT APPROVALS. PROVIDE ONE COPY OF ACCEPTANCE TEST PROCEDURES FOR REVIEW. <br />VISUALLY OBJECTIONABLE CONDUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO <br />ADDITIONAL COST. <br />WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, CONDUITS SHALL BE ROUTED NEATLY <br />AND IN PARALLEL TO STRUCTURES OR DUCT WORK. <br />ALL WIRING SHALL BE INSTALLED IN CONCEALED CONDUIT. ROUTE FIRE ALARM SYSTEM WIRING IN SEPARATE <br />CONDUITS FROM ALL OTHER WIRING. ADDITIONALLY: <br />WHEN CONDUIT CANNOT BE CONCEALED, CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL FROM <br />ARCHITECT/ENGINEER TO PROVIDE SURFACE RACEWAYS OR CONDUITS PRIOR TO ANY ROUGH-IN. <br />SURFACE RACEWAYS AND CONDUITS SHALL BE PROPERLY PREPARED AND <br />PAINTED - COLOR AS SELECTED BY ARCHITECT/ENGINEER. <br />1. <br />2. <br />3. <br />a. MONITORING ACCOUNT NUMBER <br />b. PRIMARY RECEIVER PHONE NUMBER <br />c. SECONDARY RECEIVER PHONE NUMBER <br />d. RECEIVER TYPE <br />e. TRANSMISSION FORMAT <br />f. MONITORING COMPANY NAME <br />g. MONITORING COMPANY MAIN PHONE <br />h. CONTACT PERSON AT MONITORING COMPANY <br />UDACT PROVISIONING SHALL BE INCLUDED IN THE BASE BID BASED ON THE FOLLOWING ASSUMPTIONS: <br />ASSUME THE FOLLOWING INFORMATION WILL BE PROVIDED BY THE OWNER TO PROGRAM AN INSTALLED UDACT TO A <br />THIRD-PARTY CENTRAL STATION: <br />ASSUME THIRD-PARTY CENTRAL STATION PROVIDER SHALL PROVIDE 72 HOURS ADVANCE NOTICE FOR FIRE ALARM <br />CONTRACTOR/INSTALLER TO BE PRESENT FOR UDACT PROGRAMMING, PRE-TESTING, TESTING, AND CONNECTION. <br />ASSUME A REPRESENTATIVE FROM THE THIRD-PARTY CENTRAL STATION IS REQUIRED AT LOCATION AT TIME OF PROGRAMMING, <br />PRETEST AND CONNECTION. ADDITIONALLY, THIRD-PARTY CENTRAL STATION PROVIDER SHALL PROVIDE ANY MONITORING <br />REPORTS REQUIRED BY THE FIRE DEPARTMENT. A SEPARATE PERMIT WILL BE SUBMITTED AND PAID FOR BY THE THIRD-PARTY <br />CENTRAL STATION PROVIDER. <br />FIRE ALARM SYSTEM SPECIFICATIONS <br />FACP <br />FAAP <br />FATC <br />FAPS <br />VECP <br />F <br />SF <br />MS <br />F <br />SF <br />S <br />B <br />S <br />SD <br />HD <br />W <br />T <br />PV <br />M <br />C <br />CR <br />R <br />GAMEWELL - FCI LCD-E3 (FOR USE WITH E3 CLASSSIC) <br />GAMEWELL-FCI E3 CLASSIC - FOR USE IN ONE THRU THREE <br />STORY BUILDING WITH OR WITHOUT VEC REQUIREMENT. <br />GAMEWELL - FCI E3 CLASSIC - FOR USE IN ONE THRU FIVE <br />STORY BUILDINGS WITH ELEVATORS IN A CAMPUS <br />ENVIRONMENT WITH OR WITHOUT VEC REQUIREMENT. <br />24"x24"x6" METAL CABINET WITH SCREW COVER (FOR USE WITH <br />NFS2-640 & NFS2-3030) <br />18"x 18"x 4" METAL CABINET WITH SCREW COVER (FOR USE <br />WITH NFS-320) <br />(RETURN AIR, AREA, IN-DUCT AREA) <br />SPEAKER: <br />SPEAKER/ STROBE: <br />FATC: <br />GAMEWELL-FCI #MS-7AF <br />GAMEWELL-FCI #ASD-PL2F PHOTOELECTRIC <br />ANNUNCIATOR: <br />POWER SUPPLY(FAPS): <br />STROBE: <br />MANUAL STATION: <br />SMOKE DETECTORS: <br />GAMEWELL - FCI #HPF24S6 <br />VECP: <br />FIRE ALARM SYSTEM PRODUCTS (GAMEWELL-FCI) <br />SYSTEM SENSOR #FCO-951SMOKE / CO DETECTORS: <br />SOUNDER BASE (INTELLIGENT): <br />AUTHORIZATION LETTERS: LETTER FROM THE FIRE ALARM EQUIPMENT MANUFACTURER STATING THAT THE <br />FIRE ALARM CONTRACTOR IS A FACTORY AUTHORIZED DISTRIBUTOR, AND IS TRAINED AND CERTIFIED FOR <br />THE EQUIPMENT PROPOSED ON THIS PROJECT AND IS LICENSED TO PURCHASE AND INSTALL THE <br />SOFTWARE REQUIRED TO PROVIDE THE SPECIFIED FUNCTIONS. <br />D. <br />SYSTEM SENSOR #B200-S (WHERE COMBINATION CO/ <br />SMOKE DETECTORS ARE REQUIRED) <br />SYSTEM SENSOR #B200-SLF (LOW FREQUENCY SOUND <br />FOR USE IN SLEEPING AREAS) <br />SYSTEM SHALL BE GAMEWELL - FCI TO MATCH EXISTING ON CAMPUS. <br />SYSTEM SENSOR #L-SERIES <br />SYSTEM SENSOR #L-SERIES <br />SYSTEM SENSOR #L-SERIES <br />CONNECTED LIFE SAFETY SERVICES (CLSS): THE CLSS IS AN INTERFACE FOR COMMUNICATING SYSTEM EVENTS VIA OWNER <br />LOCAL AREA NETWORK. CLSS SHALL BE CONFIGURED WITH A FIXED IP ADDRESS (FURNISHED BY OWNER-IMPLEMENTED BY <br />CONTRACTOR) TO ALLOW AUTOMATIC EMAIL OR CELL PHONE TEXT MESSAGING IN RESPONSE TO ANY SYSTEM EVENT. <br />ADDITIONAL CLSS UNITS SHALL ALLOW VIEWING OF SYSTEM STATUS, SYSTEM EVENT HISTORY AND DEVICE PROPERTIES BASED <br />ON ACCESS PERMISSIONS DEFINED BY THE OWNER. CONTRACTOR SHALL INCLUDE (8) HOURS OF CLSS CONFIGURATION BASED <br />ON OWNER INPUT COMBINED WITH CONFIGURATION TRAINING FOR THE OWNER'S REPRESENTATIVES IN BASE BID. <br />1/2"C., 2 #12 & 1 #12 GRD. <br />FACPFAPS <br />1/2"C., 2 #12 & 1 #12 GRD. <br />FAPS OR VEC <br />QTY. AS REQUIRED <br />FATCFATC CLSS <br />ALARM CONDUCTORS <br />1/2"C., WITH FIRE <br />1"C., WITH FIRE ALARM <br />CONDUCTORS, TYP. <br />U.O.N. <br />J <br />J <br />UDACT <br />3/4"C., WITH DATA <br />CABLING AS REQUIRED. <br />SPC <br />SOLE PATH COMMUNICATOR (CELLULAR) BY <br />OWNER'S MONITORING COMPANY/ VENDOR. <br />LOCATE WITHIN 20FT OF FACP. WHERE <br />REQUIRED PROVIDE REMOTE ANTENNA KIT <br />WITH CABLE/CONDUIT AND BOXES AS <br />REQUIRED TO MEET MFG SPECIFICATIONS <br />SPC <br />SPECIFICATIONS <br />FIRE ALARM VOICE EVACUATION AUDIO AMPLIFIER - SEE SPECIFICATIONS.AMP <br />AUDIO AMPLIFIER (AMP):GAMEWELL - FCI #AA SERIES <br />21159.00 <br />1202 W Edinger <br />Ave10/3/2024