1118 S Hickory St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hickory St
>
1118 S Hickory St
>
1118 S Hickory St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:56:51 AM
Creation date
6/1/2025 11:56:33 AM
Metadata
Fields
Template:
Plan
Permit Number
20179517
101114928
Full Address
1118 S Hickory St
Document Relationships
101114928 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Hickory St\1118 S Hickory St
20179517 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Hickory St\1118 S Hickory St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 11:56 AM
Modified:
5/30/2025 11:48 AM
Text:
http://www.myntsolar.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />PV-6 <br />11" X 17" <br />MYNT SOLAR, INC. <br />(801) 349-6475 <br />Email - Service@myntsolar.com <br />www.myntsolar.com <br />MA <br />R <br />I <br />E <br />L <br />A <br /> <br />M <br />A <br />N <br />R <br />I <br />Q <br />U <br />E <br />Z <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />1 <br />1 <br />1 <br />8 <br /> <br />S <br /> <br />H <br />I <br />C <br />K <br />O <br />R <br />Y <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />0 <br />1 <br />1 <br />0 <br />7 <br />5 <br />2 <br />8 <br />PHOTOVOLTAIC PROJECT INFO <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br />S <br />C <br />E <br />PV MODULE: <br />INVERTER: <br />(9) HANWHA Q.PEAK DUO BLK <br />ML-G10+ 400 <br />(5) AP SYSTEM DS3-S <br />MICROINVERTERS(240V) <br />3.60 kW (DC) / 3.20 kW (AC) <br /> ARRAY1 AZIMUTH: 180° <br />CEC 2022 / CRC 2022 / CBC 2022 <br />PROJECT NAME <br />04-19-2023 <br />REV. BYDATE <br />ARRAY TILT: 18° <br /> ARRAY2 AZIMUTH: 270° <br />ELECTRICAL NOTES <br />PV MODULE RATING @ STC <br />MANUFACTURER <br />MAX. POWER-POINT CURRENT (IMP) <br />MAX. POWER-POINT VOLTAGE (VMP) <br />OPEN-CIRCUIT VOLTAGE (VOC) <br />SHORT-CIRCUIT CURRENT (ISC) <br />10.77 AMPS <br />37.13 VOLTS <br />45.30 VOLTS <br />11.14 AMPS <br />NOM. MAX. POWER AT STC (PMAX) <br />VOC TEMPERATURE COEFFICIENT <br />400 WATT <br />-0.27° %/°K <br />Q.PEAK DUO BLK ML-G10+ 400 <br />16.APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED <br />WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER <br />THROUGH FINAL BUILDING INSPECTOR OR A COUNY OF SAN <br />BERNARDINO SELF - CERTIFICATION FORM. SMOKE ALARMS ARE <br />REQUIRED TO BE INSTALLED IN ALL BEDROOMS,OUTSIDE EACH <br />BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON <br />MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT <br />LEAST ONE ON EACH FLOOR OF THE HOUSE [R314.1,R315.1] <br />17.NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. <br />ELECTRICAL NOTE: <br />1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 2022 <br />CEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING <br />ELECTRICAL UTILITY COMPANY AND OF THE LOCAL AUTHORITY <br />HAVING JURISDICTION. <br />2. BI-DIRECTIONAL UTILITY METER TO BE INSTALLED BY UTILITY <br />COMPANY (WHEN REQUIRED). <br />3. BI-DIRECTIONAL UTILITY METER TO BE INSTALLED BY UTILITY <br />COMPANY (WHEN REQUIRED). <br />4. LABEL BREAKER "PHOTOVOLTAIC ELECTRIC POWER SOURCE". PER <br />CEC 705.10 AND "BREAKERS ARE BACKFED" PER CEC 690.64(B)(5). <br />LABEL WITH THE MAXIMUM AC OUTPUT OPERATING CURRENT AND <br />THE OPERATING VOLTAGE PER CEC 690.54. <br />5. LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER CEC <br />690.14(C)(2). LABEL WITH OPERATING CURRENT, OPERATING <br />VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT <br />CURRENT PER CEC 690.53. SWITCH TO BE LOCKED PER CEC 690.7(d). <br />6. LABEL "PHOTOVOLTAIC POWER SYSTEM DEDICATED kWH METER". <br />7. PROVIDE WARNING SIGN PER CEC 690.17 READING <br />"WARNING-ELECTRICAL SHOCK HAZARD- DO NOT TOUCH TERMINALS- <br />TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN <br />THE OFF POSITION". <br />8. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON <br />POWER INVERTER AND SOLAR MODULES PER CEC 110.3(b). <br />9. METALLIC CONDUIT SHALL BE USED WITHIN BUILDING PER CEC <br />690.31(E). <br />10. LABEL "DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL" AND " <br />LOADS NOT TO BE ADDED TO THIS PANEL. <br />11. GEC TO BE INSTALL AS REQUIRED BY MANUFACTURER <br />INSTRUCTIONS AND CEC 690.47 <br />12. PER CEC 690.64 B.2: THE SUM OF THE AMPERE RATINGS OF <br />OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE <br />BUS BAR SHALL NOT EXCEED 120% THE RATING OF THE BUS BAR OR <br />CONDUCTOR FOR A DWELLING UNIT. <br />13. THE PV PANELS AND THE INVERTERS REQUIRE NEGATIVE <br />GROUNDING PER MANUFACTURE'S INSTRUCTIONS. <br />14. ANTI-ISLANDING PROTECTION ENSURES THE SYSTEM WILL NOT <br />EXPORT POWER INTO A BALANCED 60 Hz RESONANT LOAD WHILE <br />THE UTILITY IS DISCONNECTED. <br />15. PER CEC 690.64(B)(7): UNLESS THE PANELBOARD IS RATED NOT LESS <br />THAN THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT <br />DEVICES SUPPLYING IT, A CONCECTION IN A PANELBOARD SHALL BE <br />POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER <br />LOCATION OR MAIN CIRCUIT LOCATION. THE BUS OR CONDUCTOR <br />RATING SHALL BE SIZED FOR THE LOADS CONCECTED IN <br />ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL <br />SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT WITH THE <br />FOLLOWING OR EQUIVALENT MARKING: "WARNING INVERTER <br />OUTPUT CONCECTION DO NOT RELOCATE THIS OVERCURRENT <br />DEVICE" <br />ELECTRICAL NOTES <br />1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET <br />ENVIRONMENT. <br />3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, <br />AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL <br />COMPLY WITH CEC 110.26. <br />5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL <br />FURNISH ALL CECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL <br />APPLICABLE CODES AND STANDARDS. <br />6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE <br />CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE <br />SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR <br />ILSCO GBL-4DBT LAY-IN LUG. <br />10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CEC 690. <br />11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. <br />12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER CEC <br />310.15(B)(16). <br />THIS PANEL IS FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />AC OUTPUT CURRENT <br />NOMINAL AC VOLTAGE 240V <br />13.3A <br />Rooftop conductor ampacities designed in <br />compliance with art. 690.8, Tables <br />310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), <br />310.15(B)(16), Chapter 9 Table 4, 5, & 9. <br />Location specific temperature obtained from <br />ASHRAE 2017 data tables <br />AMBIENT TEMP (HIGH TEMP 2%) <br />RECORD LOW TEMP 2° <br />31° <br />CONDUIT HEIGHT 0.5" <br />ROOF TOP TEMP 53° <br />CONDUCTOR TEMPERATURE RATE 90° <br />INVERTER SPECIFICATIONS <br />MODEL <br />NOMINAL OUTPUT CURRENT <br />640VA <br />NOMINAL AC VOLTAGE <br />2.66A <br />NOMINAL VOLTAGE RANGE <br />240 VOLTS <br />NOMINAL FREQUENCY <br />POWER FACTOR <br />MAX AC OUTPUT CURRENT <br />211V/264V <br />59.3-60.5 HZ <br />MAXIMUM CONTINOUS OUTPUT POWER <br />< 0.99 <br />15.96A <br /> DS3-S MICROINVERTER <br />MANUFACTURER AP SYSTEM <br />MODEL <br />HANWHA <br />Structural Only <br />R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R <br />C I V I L <br />No. C70784 <br />Exp. 06/30/2025 <br />S T A T E O F C A L I F O R N IA <br />PHONG TR UONG <br />1118 S Hickory St <br />06/05/23