Laserfiche WebLink
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />PV-5 <br />11" X 17" <br />MYNT SOLAR, INC. <br />(801) 349-6475 <br />Email - Service@myntsolar.com <br />www.myntsolar.com <br />MA <br />R <br />I <br />E <br />L <br />A <br /> <br />M <br />A <br />N <br />R <br />I <br />Q <br />U <br />E <br />Z <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />1 <br />1 <br />1 <br />8 <br /> <br />S <br /> <br />H <br />I <br />C <br />K <br />O <br />R <br />Y <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />0 <br />1 <br />1 <br />0 <br />7 <br />5 <br />2 <br />8 <br />PHOTOVOLTAIC PROJECT INFO <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br />S <br />C <br />E <br />PV MODULE: <br />INVERTER: <br />(9) HANWHA Q.PEAK DUO BLK <br />ML-G10+ 400 <br />(5) AP SYSTEM DS3-S <br />MICROINVERTERS(240V) <br />3.60 kW (DC) / 3.20 kW (AC) <br /> ARRAY1 AZIMUTH: 180° <br />CEC 2022 / CRC 2022 / CBC 2022 <br />PROJECT NAME <br />04-19-2023 <br />REV. BYDATE <br />ARRAY TILT: 18° <br /> ARRAY2 AZIMUTH: 270° <br />THREE LINE <br />DIAGRAM <br />ELECTRICAL SCHEMATIC <br />SCALE: NTS1 <br />UTILITY FEED + TOTAL BACKFEED <br />200A + 20A = 220A <br />LESS OR EQUAL TO <br />BUS RATING x 120% <br />200A x 120% = 240A <br />INTERCONNECTION 120% RULE <br />(MAIN PANEL) <br />G <br />N <br />1 <br />2 <br />1 <br />2 <br />ON OFF <br />PV VISIBLE LOCKABLE <br />LABELED DISCONNECT <br />(30A UNFUSED 1PH 240VAC) <br /> MCB-01 LC-01 <br /> MS-01 <br />LC-01 <br />AC wire details <br />WireID #Inverter Nominal <br />Voltage <br />Backfeed *1.25 <br />/cond. set <br />Min <br />OCPD <br />Total <br />Power <br />Conductor <br />sets <br />ccConductors <br />/conduit <br />Expected <br />max temp <br />Adjusted ampacity (ampacity x temp <br />derate x conduit fill derate) <br />Conductor & <br />neutral size <br />EGC size <br />(Cu) <br />Conductor <br />metal <br />Min EMT <br />size <br />MS-01 05 240 V 16.62 A 20 A 3.20 kW 1 2 31 30 x 0.96x 1.00 = 28.8 A 12 AWG PV 06 AWG BARE <br />(NOT IN CONDUIT)Cu - <br />MCB-01 05 240 V 16.62 A 20 A 3.20 kW 1 2 31 40 x 0.96x 1.00 = 38.4 A 10 AWG THWN-2 10 AWG THWN-2 Cu 3/4" <br />LC-01 05 240 V 16.62 A 20 A 3.20 kW 1 2 31 35 x 0.94 x 1.00 = 32.9 A 10 AWG THWN-2 08 AWG THWN-2 Cu 3/4" <br />SYSTEM SUMMARY STC DC/AC <br />(3.60 KW DC / 3.20 KW AC) <br />STC DC: (9) 400 = 3.60 KW <br />STC AC: (05) 640 = 3.20 KW <br />- (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES <br />- (05) AP SYSTEM DS3-S (240V) MICROINVERTERS <br />· 1X CIRCUIT OF 9 MODULES CONNECTED IN SERIES <br />ELECTRICAL NOTES <br />1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS <br />APPLICATION. <br />2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET <br />ENVIRONMENT. <br />3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED <br />DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, <br />OR VALLEY. <br />4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT <br />SHALL COMPLY WITH CEC 110.26. <br />5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR <br />SHALL FURNISH ALL CECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES <br />TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT <br />SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND <br />MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S <br />INSTRUCTION. <br />9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB <br />LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CEC 690. <br />11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF <br />INSTALL. <br />12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER <br />CEC 310.15(B)(16). <br />1 <br />1 <br />2 <br />G <br />N <br />2 1 <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />N <br />G <br />N <br />JUNCTION BOX <br />600V, NEMA 3R <br />UL LISTED AC COMBINER PANEL <br />20(N) <br />G <br />N <br />TO <br />UTILITY <br />GRIDM <br />200A(E) <br />20A(N) <br />MAIN SERVICE PANEL <br />(EXISTING, BOTTOM-FED) <br />BUS RATING: 200A <br />MAIN BREAKER: 200A (E) <br />UTILITY METER <br />UTILITY: SOUTHERN <br />CALIFORNIA EDISON CO <br />SERVICE: 240V 60HZ 1P <br />MOD: HANWHA Q.PEAK DUO BLK ML-G10+ 400 <br />INV: AP SYSTEM DS3-S-MICRO (240V) <br />(1 CIRCUIT X 4 MICRO-INV(1:2)X1 MICRO-INV(1:1)) <br />09 <br />Structural Only <br />R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R <br />C I V I L <br />No. C70784 <br />Exp. 06/30/2025 <br />S T A T E O F C A L I F O R N IA <br />PHONG TRUONG <br />1118 S Hickory St <br />06/05/23