Laserfiche WebLink
(N) (12) JA SOLAR JAM54S31-395/MR/(395W) MODULES <br /> WITH (6) AP SYSTEM DS3-L MICRO-INVERTER <br />ATTACHED TO THE BACK OF MODULE IN PAIR OF TWO. <br />PV CIRCUIT 1: 6 MODULES/PARALLEL [(3) AP SYSTEM DS3-L 2 IN 1] <br />RO <br />O <br />F <br />TOP <br />GR <br />O <br />U <br />N <br />D <br /> <br />LEV <br />EL <br /> <br />- <br />HOUSE EX <br />TER <br />IOR <br />20A <br />20A <br />N <br />2 (N) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />40A <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL <br />(N) 100A PV LOAD <br />CENTER <br />156 112 <br />1 <br />5 <br />PV CIRCUIT 2: 6 MODULES/PARALLEL [(3) AP SYSTEM DS3-L 2 IN 1] <br />112 <br />(E) VISIBLE <br />LOCKABLE <br />2 POLE 60A <br />'KNIFE' A/C <br />DISCONNECT <br />G <br />L1 <br /> <br />N <br />G G <br />(E) ABB PVI-3.0-OUTD-U-US-Z-A <br />INVERTER <br />(E) (13) KYOCER KU265-6ZPA <br />MODULES <br />ST <br />R <br />I <br />N <br />G <br /> <br /># <br />1 <br />EXISTING WIRE <br />EXISTING WIRE <br />L2 <br /> <br />(E) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />EXISTING WIRE <br />N <br />20A <br />20A <br />100A/240V <br />LOAD CENTER <br />G <br />L1 <br />N <br />GG <br />ST <br />R <br />I <br />N <br />G <br /> <br /># <br />1 <br /> <br />EXISTING WIRE <br />EXISTING WIRE <br />L2 <br />M <br />POINT OF <br /> DELIVERY AND <br />INTERCONNECTION <br />60A <br />175A <br />N <br />(E) GROUNDING <br />ELECTRODE OR <br />(UFER) <br />BACKFEED <br />BREAKER <br />3 <br />EXISTING <br />240V/200A <br />MAIN SERVICE PANEL <br />SINGLE PHASE <br />PV CIRCUIT 1: 13 MODULES/PARALLEL <br />PV CIRCUIT 1: 13 MODULES/PARALLEL <br />6 5 <br />(E) ABB PVI-3.0-OUTD-U-US-Z-A <br />INVERTER <br />(E) (13) KYOCER KU265-6ZPA <br />MODULES <br />(E) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />(N)MAIN BREAKER <br />DERATED TO 175A <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br /> 1228 W MYRTLE ST, <br /> SANTA ANA, <br /> CA 92703 <br /> APN:01011129 <br /> DATE:8/7/2023 <br />RIVAS <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: ORG <br />CORE ENERGY GROUP. <br />ADDRESS: 2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />E-1 <br />DESIGN TEMPERATURES <br />ASHRAE EXTREME LOW -1°C <br />ASHRAE 2% HIGH 36°C <br />PV Module Ratings @ STC <br />Module Make/Model <br />JA SOLAR <br />JAM54S31-395/MR/(395W) <br />MODULE <br />Max Power-Point Current (Imp)12.81A <br />Max Power-Point Voltage (Vmp)30.84V <br />Open-Circuit Voltage (Voc)36.98V <br />Short-Circuit Current (Isc)13.70A <br />Max Series Fuse (OCPD)25A <br />Nominal Maximum Power at STC (Pmax)395W <br />Maximum System Voltage 1500V <br />Voc Temperature Coefficient -0.275% /°C <br />Conduit and Conductor Schedule ~ (75°C Copper Column) <br />Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size <br />1 AP SYSTEM'S AC BUS CABLE 12 AWG 2 N/A - Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 10 AWG 4 EMT 3/4" <br />2 THWN-2 - Ground 8 AWG 1 EMT 3/4" <br />3 <br />3 <br />THWN-2 6 AWG 3 EMT 3/4" <br />THWN-2 - Ground 8 AWG 1 EMT 3/4" <br />Inverter Ratings <br />Inverter Make/Model AP SYSTEM DS3-L <br />Max DC Volt Rating 60V <br />Peak Output Power 768W <br />Max Nominal Voltage 240V <br />Max AC Current 3.2A <br />Max OCPD Rating 20A <br />METER # 222012785965 <br />"60.25A TOTAL BACKFEED, ROUNDED <br />DOWN TO 60A PER NEC/CEC 220.5(B)" <br />EXISTING PV SYSTEM IS NOT RSD COMPLIANT <br />SYSTEM SUMMARY <br />BRANCH #1 <br />INVERTERS PER BRANCH 3 <br />MAX AC CURRENT 9.6A <br />MAX AC OUTPUT POWER 2304W <br />ARRAY STC POWER 4740W <br />ARRAY PTC POWER 4424W <br />MAX AC CURRENT 19.20A <br />MAX AC POWER 4608W <br />DERATED (CEC) AC POWER 4269.54W <br />BRANCH #2 <br />3 <br />9.6A <br />2304W <br />MAIN SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 200A <br />MAX BREAKER SIZE: <br />(200A X 1.2) - 175A = 65.0A <br />Signed: 07/17/2023 <br />Structural <br />Only <br />1228 W Myrtle St - <br />2018034508/16/23