N <br />1. NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD <br />REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. <br />2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE <br />3. ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE <br />PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP <br />RIVETS OR SCREWS OR OTHER APPROVED METHOD. <br />4. DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, <br />MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE <br />WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. <br />PERMANENT SIGNAGE NOTES: <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(3)(2) <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(3)(3) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C)(4) & <br />690.13(B) <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR <br />OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2022: 690.56(C)(2), <br />CFC 2022: 1204.5.3 <br />POWER TO THIS BUILDING IS <br />ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH <br />DISCONNECTS AS SHOWN <br />CAUTION: <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 19.20 AMPS <br />240.0 VAC <br />PHOTOVOLTAIC AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br /> 1228 W MYRTLE ST, <br /> SANTA ANA, <br /> CA 92703 <br /> APN:01011129 <br /> DATE:7/17/2023 <br />RIVAS <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: ORG <br />CORE ENERGY GROUP. <br />ADDRESS: 2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />E-2 <br />12 <br />2 <br />8 <br /> <br />W <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />WARNING! <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />WARNING! <br />DO NOT UPSIZE MAIN BREAKER- <br />MAIN BREAKER DERATED TO <br />150AMPS DO NOT UPSIZE <br />(N) SOLAR PANELS AND <br />MICRO-INVERTERS ON ROOF <br />LOCATION OF EXISTING TWO <br />STRING INVERTER AC <br />DISCONNECT & PV LOAD <br />CENTER <br />PV INTERCONNECTION POINT. <br />LOCATION OF METER MAIN COMBO , AC <br />DISCONNECT & PV LOAD CENTER <br />(E) PV SYSTEM IS NOT RSD <br />COMPLIANT <br />(E) SOLAR PANELS <br />MAXIMUM AC OPERATING CURRENT <br />(NEW AND EXISTING SYSTEM) : 48.2 AMPS <br />PHOTOVOLTAIC AC DISCONNECT <br />NOMINAL OPERATING AC VOLTAGE: 240.0 VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2019: 690.54 <br />1228 W Myrtle St - <br />2018034508/16/23