Laserfiche WebLink
1. Framing lumber shall be Douglas Fir-Larch, grade marked by W.W.P.A. or W.C.L.I.B. as <br />follows, unless noted on plans: <br />4” x & 6” x and Larger No. 1 Grade or Better <br />2” x 6” and Larger <br />4” x 4” and Larger No. 1 Grade or Better <br />No. 2 Grade or Better <br />Vertical Framing <br />Standard Grade or Better2” x 4” <br />WOOD FRAMING: <br />8. Anchor bolts shall be 5/8” in diameter by 12” long with 3”x3”x0.229” washers embedded 9” <br />minimum into concrete or masonry, unless noted otherwise on plans. See shear wall schedule <br />and plans for spacing. Install a minimum of 2 bolts in each piece of p <br />9. Joists or rafters framing from opposite sides of beams or walls shall be lapped a minimum of <br />6” and spliced with 4-16d nails, unless noted otherwise on plans. <br />10. Beams built-up with more than 2-2”x members shall have all pieces full length and shall <br />have 1/2" bolts at 18” O.C. staggered top and bottom 3” from the edges, with the first bolt 3- <br />11. All flush framed 2”x connections shall be made with Simpson “LUP” series hangers, unless <br />noted otherwise on the plans. <br />12. All flush framed 2”x and larger connections shall be made with Simpson “B” series hangers, <br />unless noted otherwise on the plans. <br />13. Lap all 2x top plates a minimum of 4’-0” at splices and nail with 10-16d on each side of <br />each splice, unless noted otherwise on the plans. Where top or sill plates are cut, use a 1/8” x 1- <br />1/2” metal strap with 10-16d on each side of cut. <br />6. Bolts shall conform to ASTM A-307-03. Provide washers under all bolts, nuts, and screw <br />heads.7. Provide double joists under all parallel walls and solid blocking under walls perpendicular to <br />floor joists. <br />No. 2 Grade or Better2” x <br />Horizontal Framing <br />2. Plywood roof and floor sheathing shall be as noted on plans. Plywood for shear walls shall <br />be a minimum of Structural II. All sheets shall conform to DOC PS-1 and shall be bonded with <br />3. Each plywood sheet shall have a minimum area of 8 square feet and a minimum dimension of <br />2 feet in any direction. Plywood shall be installed with joints staggered in adjacent sheets, with <br />each sheet continuous over 2 or more supports and the face grai <br />4. All nails shall be common wire nails with minimum nailing per Tables 11N-11R, of NDS for <br />wood construction, unless shown otherwise. <br />5. All framing hardware shown are strong-Tie Connectors as manufactured by the Simpson <br />Company, unless noted otherwise. All hardware to be installed per manufacturer’s <br />4 <br />1311 N Towner St <br />9/24/2024