My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1327 S Joane Way - Plan
PBA
>
Building
>
ProjectDox
>
J
>
Joane Way
>
1327 S Joane Way
>
1327 S Joane Way - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:57:12 AM
Creation date
6/1/2025 11:57:02 AM
Metadata
Fields
Template:
Plan
Permit Number
20177827
101112596
Full Address
1327 S Joane Way
Document Relationships
101112596 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Joane Way\1327 S Joane Way
20177827 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Joane Way\1327 S Joane Way
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
J-BOX <br />NEMA3R <br />A B <br />+- <br />DC <br />DC <br />INTEGRATED <br />DC DISCONNECT & AFCI <br />AC <br />DC <br />SOLAREDGE TECHNOLOGIES <br />SE5000H-US (240V) <br />HD WAVE INVERTER STRING 1: <br />(14) APTOS SOLAR TECHNOLOGY <br /> (DNA-144-MF26-440W) 440 WATT <br />SOLAR MODULES PAIRED WITH <br />(14) S440 OPTIMIZERS IN <br />(1) SERIES STRING <br />SOLAREDGE <br />S440 OPTIMIZER <br />(N) LOCKABLE <br />BLADE TYPE <br />NON-FUSIBLE <br />AC DISCONNECT <br />NEMA 3R <br />C <br />M <br />(N) GROUND <br />NEW 200A <br />MAIN BREAKER <br />(END FED) <br />NEW 200A <br />MAIN PANEL <br />30A PV BREAKER <br />INSTALLED AT OPPOSITE END OF <br />BUSBAR FROM MAIN BREAKER <br />30A-2P <br />200A <br />NO CENTER-FED <br />MAIN BREAKER <br />MIN 8' <br />MIN 6' <br />5' MAX <br />#4 AWG BARE <br />ARMOURED <br />CABLE <br />COLD WATER <br />BOND <br />120/240 VAC <br />SINGLE PHASE SERVICE <br />(OVERHEAD) <br />30A-2P <br />120/240VAC <br />(N) (L1,L2,N) 3/0 AWG <br />CU THHN/THWN-2 <br />PV-5REV: A 10/15/2022 <br />TELLES, JESSE <br />1327 SOUTH JOANE WAY <br />SANTA ANA, CA 92704 <br />APN # 10937303 TEL #: (949) 903-5649 <br />CLIENT: <br />ELECTRICAL <br />CSLB # 619149 CLASS: B, C-10 <br />NAME: GARY GIETZ, JACK MCCLARY <br />SIGNED: 8/7/22 PHONE 310.904.6139 <br />ENERGY SERVICE PARTNERS <br />970 W 190TH ST, STE 302 <br />TORRANCE, CA 90502 <br />CONTRACTOR: <br />ELECTRICAL <br />∆ <br />TAG CONDUCTOR CONDUCTOR <br />SIZE <br />NUMBER OF <br />CONDUCTORS <br />CONDUIT/CABLE <br />TYPE CONDUIT SIZE <br />A PV-WIRE 10 AWG 2 <br />FREE AIR N/A <br />EGC/GEC: BARE COPPER 6 AWG 1 <br />B THHN/THWN-2 10 AWG 2 <br />EMT 3/4" <br />EGC/GEC: THHN/THWN-2 8 AWG 1 <br />C LINE:THHN/THWN-2 10 AWG 2 <br />EMT 3/4"NEUTRAL: THHN/THWN-2 10 AWG 1 <br />EGC/GEC: THHN/THWN-2 8 AWG 1 <br />EVEREST INTEGRATED GROUNDING & LAY-IN LUGS ARE UL2703 LISTEDGROUNDING DETAIL <br />scale: NTS <br />RAILS MODULES <br />EVEREST RAIL <br />PV MODULE FRAME <br />EVEREST GROUNDING PIERCES <br />THROUGH ANODIZED COATINGS <br />OF MODULE FRAMES AND RAILS <br />EVEREST UNIVERSAL <br />FASTENING OBJECT <br />LAY-IN LUG TERMINAL <br />AL/CU DUAL RATED <br />(TIN PLATED CU) <br />SS SET SCREW INCLUDED <br />EVEREST RAIL <br />#10-24 SS LOCK NUT <br />6 AWG BARE CU WIRE <br />TE#10-24 X 3/4" SS HCS BOLT <br />#10 SS EXTERNAL TOOTH <br />LOCK (STAR) WASHER <br />SOLAREDGE NOTES: <br />1. STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND MAINTAINED AT NOMINAL 380 VDC. <br />2. STRING VOLTAGE IS LIMITED BY INVERTER TO A MAXIMUM OF 480VDC <br />3. SOLAREDGE DC/DC OPTIMIZERS ARE ALL RUN IN SERIES PER STRING (FIXED SOURCE CIRCUIT VOLTAGE - DC/DC CONVERTERS) <br />4. STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS LIMITED TO 15ADC MAX (PER STRING). <br />5. INTEGRATED SOLAREDGE DC SWITCH DISCONNECTS BOTH POSITIVE AND NEGATIVE CONDUCTORS AS REQUIRED. <br />6. SOLAREDGE INVERTERS ARE ALL RAPID SHUTDOWN READY PER CEC 690.12 <br />7. SOLAREDGE INVERTER IS SMART INVERTER COMPLIANT PER CALIFORNIA RULE 21. <br />8. SOLAREDGE INVERTERS ARE UL1699B CERTIFIED, PROVIDING CEC 2019 690.11 COMPLIANCE <br />SYSTEM NOTES: <br />1. PV SYSTEM IS UNGROUNDED <br />2. MODULES ARE BONDED TO RAIL USING EVEREST GROUNDING. <br />3. RAILS ARE BONDED USING UL 2703 RATED LAY-IN LUGS <br />4. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA IRREVERSIBLE CRIMP; GEC TO <br />BE CONTINUOUS PER CEC 250.64(C) <br />ALL TERMINALS <br />ARE 75° CELSIUS <br />RATED <br />SOLAR PV CIRCUIT BREAKER <br />MAIN SERVICE BUS RATING <br />PER CEC 705.12(B)(2)(3)(b) <br />200A x 120% = 240A <br />TOTAL BUS LOAD = (21A x 1.25) + 200A <br />TOTAL SYSTEM <br />TOTAL NUMBER OF MODULES 14 <br />TOTAL NUMBER OF OPTIMIZERS 14 <br />GROUNDING NOTES: <br />1. TWO GROUND RODS TO BE INSTALLED AT MINIMUM 6' APART WITH 8' MINIMUM EMBEDMENT TO GROUND. GROUNDING ELECTRODE <br />AND BONDING CONDUCTOR (COPPER) TO HAVE #4 AWG BARE ARMOURED CABLE. <br />2. CONNECTION TO THE INTERIOR METAL WATER PIPING SHALL BE MADE WITHIN 5' FROM POINT OF ENTRANCE. CEC 250.68(C)(1) <br />3. GROUNDING ELECTRODE CONDUCTOR SHALL BE CONNECTED WITHIN 5' FROM POINT OF ENTRANCE TO A COLD WATER PIPE <br />GROUNDING ELECTRODE <br />NOTE: <br />PROPOSED NEW MAIN PANEL IS IN THE SAME <br />LOCATION AS EXISTING PANEL. IF PROPOSED NEW MAIN <br />PANEL IS LOCATED MORE THAN 6 FEET FROM THE EXISTING <br />MAIN PANEL, COMBINATION-TYPE AFCI BREAKERS SHALL BE <br />USED AS METHOD OF PROTECTION FOR ALL 15A/1P AND <br />20A/1P (120V) LOADS PER 210.12(D). <br />WE ARE OVERDRIVING THE INVERTER <br />STRING INPUT WATTAGE BY SOLAREDGE <br />ALLOWANCE. PLEASE REFER TO THE <br />OPTIMIZER SPEC SHEET. <br />1327 S Joane Way <br />11/04/22
The URL can be used to link to this page
Your browser does not support the video tag.