My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1327 S Joane Way - Plan
PBA
>
Building
>
ProjectDox
>
J
>
Joane Way
>
1327 S Joane Way
>
1327 S Joane Way - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:57:12 AM
Creation date
6/1/2025 11:57:02 AM
Metadata
Fields
Template:
Plan
Permit Number
20177827
101112596
Full Address
1327 S Joane Way
Document Relationships
101112596 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Joane Way\1327 S Joane Way
20177827 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Joane Way\1327 S Joane Way
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV-6REV: A 10/15/2022 <br />TELLES, JESSE <br />1327 SOUTH JOANE WAY <br />SANTA ANA, CA 92704 <br />APN # 10937303 TEL #: (949) 903-5649 <br />CLIENT: <br />CALCS <br />CSLB # 619149 CLASS: B, C-10 <br />NAME: GARY GIETZ, JACK MCCLARY <br />SIGNED: 8/7/22 PHONE 310.904.6139 <br />ENERGY SERVICE PARTNERS <br />970 W 190TH ST, STE 302 <br />TORRANCE, CA 90502 <br />CONTRACTOR: <br />ELECTRICAL CALCULATIONS <br />INVERTER CHARACTERISTICS - SOLAREDGE SE5000H-US <br />MAX OUTPUT POWER 5000 W <br />SYSTEM OPERATING VOLTAGE 380 V <br />MAX CONTINOUS OUTPUT CURRENT 21 A <br />MAX INPUT VOLTAGE 480 V <br />SYSTEM SHORT CIRCUIT CURRENT 15 A <br />CEC MAX EFFICIENCY 99 % <br />DC DISCONNECT VALUES <br />RATED MAX POWER-POINT CURRENT (IMP) 16.21 A <br />RATED MAX POWER-POINT VOLTAGE (VMP)380 V <br />MAX SYSTEM VOLTAGE (VOC)480.00 V <br />MAX SHORT CIRCUIT CURRENT (ISC)15 A <br />SYSTEM CHARACTERISTICS CALCULATIONS <br />VMP Inverter Fixed String Voltage 380 V 380 V <br />VOC Max Inverter System Voltage 480 V 480 V <br />IMP (DC System Size)/ VMP 6160 W / 380 V 16.21 A <br />ISC (Optimizer Max Output Current) x (# Strings)15 A x 1 15 A <br />AC WIRE SIZING CALCULATIONS <br />AFTER INVERTER Wire = 10 AWG, 40 A @ 90⁰C <br />MAX AC OUTPUT CURRENT (Max Inverter Output) x (Continuous Load)[690.8(B)(1)]21 A X 1.25 26.25 A <br />TOTAL AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table <br />310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.82 X 40 A X 1 32.80 A <br />26.25 A ---> 32.80 A Therefore 10 AWG OK <br />MAX AC OUTPUT CURRENT (Max Inverter Output) x (Continuous Load)[690.8(B)(1)]21 A X 1.25 26.25 A <br />26.25 ---> 30 A Overcurrent Protection <br />TEMPERATURE ADDERS <br />CONDUIT TO BE INSTALLED <br />MIN. OF 7 8" ABOVE ROOF <br />HIGH TEMPERATURE 47 °C <br />LOW TEMPERATURE -2 °C <br />TEMP ADDER FOR ROOF RUN 0 °C <br />TEMP ADDER FOR ATTIC RUN 7 °C <br />DC WIRE SIZING CALCULATIONS <br />AT ARRAY Max Optimizer Current = 15 A, Wire = 10 AWG, 40 A @ 90⁰C <br />125% MAX CURRENT (Max Optimizer Current) x (Continuous Load)[690.8(A)]15 A X 1.25 18.75 A Per 690.8(B)(1) 40 A > 18.75 A <br />DERATED AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table <br />310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.82 X 40 A X 1 32.80 A Per. 690.8(B)(2) 32.80 A > 18.75 A <br />10 AWG PV WIRE OK <br />DC WIRE SIZING CALCULATIONS <br />AT JBOX Max Optimizer Current = 15 A, Wire = 10 AWG, 40 A @ 90⁰C <br />125% MAX CURRENT (Max Optimizer Current) x (Continuous Load)[690.8(A)]15 A X 1.25 18.75 A Per 690.8(B)(1) 40 A > 18.75 A <br />DERATED AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table <br />310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.82 X 40 A X 1 32.80 A Per. 690.8(B)(2) 32.80 A > 18.75 A <br />10 AWG PV WIRE OK <br />MODULE CHARACTERISTICS - APTOS DNA-144-MF26-440W [BLK] <br />MAX POWER (PMAX) @ STC 440 W <br />OPEN CIRCUIT VOLTAGE (VOC)49.9 V <br />SHORT CIRCUIT CURRENT (ISC)11.33 A <br />MAX POWER VOLTAGE (VMP)41.0 V <br />MAX POWER CURRENT (IMP)10.74 A <br />SERIES FUSE RATING 20 A <br />OPTIMIZER CHARACTERISTICS - S440 <br />RATED INPUT DC POWER 440 W <br />MAX INPUT VOLTAGE 60 V <br />MAX INPUT CURRENT 14.5 A <br />MAX OUTPUT VOLTAGE 60 V <br />MAX OUTPUT CURRENT 15 A <br />SAFETY OUTPUT VOLTAGE/OPTIMIZER 1 V <br />MIN/MAX STRING LENGTH 8 / 25 <br />MAX POWER PER STRING [HD-WAVE] 5700 W <br />1327 S Joane Way <br />11/04/22
The URL can be used to link to this page
Your browser does not support the video tag.