ELECTRIC OUTLET AND <br />LIGHT FIXTURE <br />20' MAX. <br />30" MIN. <br />MIN. 30X30" WORKING <br />PLATFORM SECURED IN <br />PLACE <br />22x30" MIN. <br />ATTIC ACCESS <br />MIN. 24" WIDE SOLID <br />FLOORING FROM ACCESS <br />OPENING TO FURNACE <br />WORKING PLATFORM <br />LIGHT SWITCH <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />ATTIC AIR HANDLER <br />AIR HANDLER DISCONNECT <br />AND ELECTRICAL OUTLET <br />1. WINDOW MANUFACTURER AND INSTALLER SHALL INSURE THAT ALL WINDOWS MEET OR <br />EXCEED ALL EGRESS REQUIREMENTS OF CRC R310 & R312 <br />2. ALL WINDOWS AND SLIDING GLASS DOORS SHALL BE INSTALLED PER AMERICAN <br />ARCHITECTURAL MANUFACTURERS ASSOCIATION AAMA 2400=02 RECOMMENDATIONS <br />"STANDARD PRACTICE FOR INSTALLATION OF WINDOWS WITH INTEGRAL MOUNTING <br />FLANGES IN STUD FRAME CONSTRUCTION". <br />3. INSTALL AN ISOLATION MEMBRANE BELOW THE THRESHOLD OF ALL SLIDING GLASS <br />DOORS THAT REST ON A CONCRETE SLAB. <br />4. ALL SEALANT SHALL BE OF HIGH QUALITY AND REVIEWED OFR COMPATIBILITY WITH <br />ASPHALTIC MEMBRANES AND FLASHING MATERIAL. <br />44" MAXIMUM <br />24" MIN. <br />20" MINNIMUM <br />F.F. > 72" ABV. FINISH GRADE. <br />24" MINIMUM @ <br />44" MAXIMUM <br />20" MINNIMUM <br />F.F. > 72" ABV. FINISH GRADE. <br />24" MINIMUM @ <br />5.7 S.F MINIMUM <br />24" MIN. <br />5. <br />7 <br /> <br />S <br />. <br />F <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. <br />2. MIN. SET CLEAR HEIGHT OF 24 INCHES. <br />3. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE <br />FLOOR. <br />EMERGENCY EGRESS <br />WINDOW AND DOOR NOTE <br />GENERAL NOTES <br />1. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS <br />EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR <br />SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET <br />FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE. <br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING <br />CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING <br />DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES <br />BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY <br />VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS. <br />3. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; <br />FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY <br />MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. <br />CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT <br />SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY <br />SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK. <br />4. CONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP <br />DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR. <br />5. CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND <br />CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK TOGETHER WITH ANY OTHER WORK <br />WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND <br />TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT <br />MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT <br />OR FOR LONGER PERIODS. <br />6. THAT IS RESPONSIBILITY OF CONTRACTOR TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD <br />OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS. <br />7. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB- <br />CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF <br />MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF <br />SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF <br />THE OWNER AND WITHOUT COST TO OWNER. <br />8. THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. <br />ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER <br />EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE <br />RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR <br />PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR <br />EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. <br />ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO <br />THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO <br />RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER. <br />9. OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING <br />ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR. BEFORE ANY CHANGES ARE BEGUN, THE ADDED OR <br />DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL. <br />10. SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND <br />SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN W RITING FOR APPROVAL OR DENIAL. IF MORE THAN ONE MANUFACTURER IS SPECIFIED IN <br />THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR <br />STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR <br />ARCHITECT'S AND OWNER'S DECISION. <br />11. THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND <br />DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR <br />MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR <br />SUB-CONTRACTOR FINDS ANY DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT <br />IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY <br />OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND <br />THOSE INDICATED ON THE DRAWINGS. <br />12. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE <br />IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED <br />IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN <br />DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD. <br />13. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND <br />DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND <br />OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS <br />AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY <br />MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. <br />SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED <br />PROCUREMENT, FABRICATION OR CONSTRUCTION. <br />14. FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB- <br />CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR <br />MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED <br />IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR <br />APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS. <br />NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. <br />15. ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE <br />IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF <br />FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD <br />RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND <br />SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN <br />BOTH. <br />16. AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE <br />STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE STRUCTURAL FRAME, SUB- <br />CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH <br />TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO <br />FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. <br />CONTRACTOR AND HIS SUB-CONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR <br />COMPONENT PARTS. <br />17. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE <br />APPEARS HERON. <br />18. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES. <br />19. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS. <br />20. THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, <br />COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE <br />ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED <br />ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND <br />MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. <br />21. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A <br />CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE <br />PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND <br />MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER <br />SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R-VALUE. <br />22. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT. <br />23. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND <br />RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS <br />PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. <br />24. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS <br />WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR INFORMATION <br />APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HAND <br />WRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION <br />(PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). <br />U UNDER <br />U.B.C.UNIFORM BUILDING CODE <br />U.G.UNDERGROUND <br />U.L.UNDERWRITER'S LABORATORY <br />UNF.UNFINISHED <br />U.N.O.UNLESS NOTED OTHERWISE <br />UR.URINAL <br />V.VERTICAL <br />VENT.VENTILATING <br />VERT.VERTICAL <br />VER.VERIFY <br />V.T.R.VENT THROUGH ROOF <br />W.WEST, WIDE, WIDTH <br />W/.WITH <br />WD.WOOD <br />W.H.WATER HEATER <br />W.C.WATER CLOSET <br />W.I.WROUGHT IRON <br />WP.WATERPROOF <br />W.W.M.WELDED WIRE MESH <br />&AND <br /><ANGLE <br />@ AT <br />C CENTERLINE <br />∅DIAMETER OR ROUND <br />PL PROPERTY LINE, PLATE <br />A.B.ANCHOR BOLT <br />ABV.ABOVE <br />A/C AIR CONDITIONING <br />A.C.ASPHALT CONCRETE <br />ACOUS.ACOUSTICAL <br />A.D.AREA DRAIN <br />ADH.ADHESIVE <br />ADJ.ADJUSTABLE <br />AL.ALUMINUM <br />ALT.ALTERNATE <br />ANOD.ANODIZED <br />A.P.ACCESS PANEL <br />APPX.APPROXIMATELY <br />APPV'D APPROVED <br />ARCH.ARCHITECTURAL <br />ASB.ASBESTOS <br />ASSY.ASSEMBLY <br />AUTO.AUTOMATIC <br />B.BATH <br />BD.BOADRD <br />BEL.BELOW <br />BET.BETWEEN <br />BITUM.BITUMINOUS <br />BLDG.BUILDING <br />BLK.BLOCK <br />BLK'G BLOCKING <br />BM.BEAM <br />B.O.BY OWNER/BY OTHERS <br />BOT.BOTTOM <br />BR.BEDROOM <br />B.W.BACK OF WALK/ <br />BOT. OF WALL <br />CAB.CABINET <br />C.B.CATCH BASIN <br />CEM.CEMENT <br />C.G.CORNER GUARD <br />CHAN.CHANNEL <br />CHG.CHANGE <br />C.I.CAST IRON <br />C.J.CONTROL JOINT/ <br />CONST. JOINT <br />CLG.CEILING/ CEILING JOIST <br />CLKG.CAULKING <br />CLR.CLEAR <br />CNTR.COUNTER <br />CONC.CONCRETE <br />COND.CONDITION <br />CONST.CONSTRUCTION <br />CONT.CONTRACTOR/ CONTINOUS <br />CORR.CORRIDOR, CORROSIVE <br />CTSK.COUNTERSUNK <br />CTR.CENTER <br />DBL.DOUBLE <br />DECO.DECORATIVE <br />DEPT.DEPARTMENT <br />DET.DETAIL <br />D.F.DRINKING FOUNTAIN/ <br />DOUGLASS FIR <br />DIA.DIAMETER <br />DIAG.DIAGONAL <br />DIM.DIMENSION <br />DN.DOWN <br />DR.DOOR <br />D.S.DOWN SPOUT <br />D.S.P.DRY STAND PIPE <br />DWG.DRAWING <br />(E.)EXISTING/ EAST/ <br />ENTRY/ EACH <br />E.J.EXPANSION JOINT <br />EL.ELEVATION <br />ELEC.ELECTRIC <br />ELEV.ELEVATOR <br />EMER.EMERGENCY <br />ENCL.ENCLOSURE <br />E.P.ELECTRIC PANEL <br />E.Q.EQUAL/ <br />EQUIVALENT <br />EQPT/ <br />EQPM EQUIPMENT <br />E.W.EACH WAY <br />EXST.EXISTING <br />EXH.EXHAUST <br />EXPO.EXPOSED <br />EXT.EXTERIOR <br />E.G.EXISTING GRADE <br />F.FIXED <br />F.A.FIRE ALARM <br />FAC.FACTORY <br />F.C.O.FLOOR CLEAN OUT <br />F.D.FLOOR DRAIN <br />FDN.FOUNDATION <br />F.E.FIRE EXTINGUISHER <br />F.E.C.FIRE EXTINGUISHER CABINET <br />F.G.FINISH GRADE <br />F.H.FLAT HEAD <br />FIN.FINISH <br />FIX/FIXT FIXTURE <br />F.J.FLOOR JOIST <br />F.L.FLOW LINE <br />FLASH.FLASHING <br />FLR.FLOOR <br />FLUOR.FLUORESCENT <br />F.O.C.FACE OF CONCRETE/ <br />FACE OF CURB <br />F.O.F.FACE OF FINISH <br />F.O.S.FACE OF STUD/ <br />FACE OF STRUCUTRE <br />F.O.M.FACE OF MASONRY <br />FP.FIREPLACE <br />F.S.FLOOR SINK <br />FT.FOOT OR FEET <br />FTG.FOOTING <br />FURR.FURRING <br />FUT.FUTURE <br />F.V.FIELD VERIFY <br />GA.GAUGE <br />GALV.GALVANIZED <br />G.B.GRAB BAR/GRADE BEAM <br />G.C.GENERAL CONTRACTOR <br />GEN.GENERAL <br />G.F.I.GROUND FAULT INTERRUPT <br />G.I.GALVANIZED IRON <br />G.L.GLASS <br />G.L.B.GLU-LAM BEAM <br />GND.GROUND <br />GR.GRADE <br />GYP.GYPSUM <br />G.P. GRADE PLANE <br />H.HIGH <br />H.B.HOSE BIB <br />H.C.HOLLOW CORE <br />HD.HARD <br />HDR.HEADER <br />HDWD.HARDWOOD <br />HDWR.HARDWARE <br />H.M.HOLLOW METAL <br />HORIZ.HORIZONTAL <br />HR.HOUR <br />HT./HGT.HEIGHT <br />HVAC HEATING VENTILATING/ <br />AIR COND. <br />I.D.INSIDE DIAMETER/ <br />INTERIOR DESIGNER <br />IN.INCH <br />INSUL.INSULATION <br />INT.INTERIOR <br />INV.INVERT/ <br />INVERTED <br />JAN.JANITOR <br />JT.JOINT <br />JST.JOIST <br />KIT.KITCHEN <br />L.LOW/LINEN <br />L.A.LANDSCAPED AREA <br />LAB.LABORATORY <br />LAM.LAMINATE <br />LAV.LAVATORY <br />LBS.POUNDS <br />LFA.LOAD FROM ABOVE <br />L.H.LEFT HAND <br />LKR.LOCKER <br />LT.LIGHT <br />LUM.LUMINOUS <br />MAINT.MAINTENANCE <br />MAS.MASONRY <br />MAT.MATERIAL <br />MAX.MAXIMUM <br />M.B.METAL BOLT <br />M.C.MEDICINE CABINET <br />MECH.MECHANICAL <br />MEMB.MEMBRANE <br />MET/MTL.METAL <br />MFR/MFGR MANUFACTURER <br />M.H.MAN HOLE <br />MIN.MINIMUM <br />MIR.MIRROR <br />MISC.MISCELLANEOUS <br />M.O.MASONRY OPENING <br />MOS.MOSAIC <br />MTD.MOUNTED <br />MUL.MULLION <br />(N.)NEW <br />N.NORTH <br />NAT.NATURAL <br />N.I.C.NOT IN CONTRACT <br />N.G.NATURAL GRADE <br />NO.NUMBER <br />NOM.NOMINAL <br />N.T.S.NOT TO SCALE <br />O/.OVER <br />O.A.OVERALL <br />OBS.OBSCURE <br />O.C.ON CENTER <br />O.D.OUTSIDE DIAMETER/ <br />DIMENSION <br />O.F.D.OVERFLOW DRAIN <br />OFF.OFFICE <br />OPNC.OPENING <br />OPP.OPPOSITE <br />PERIM.PERIMETER <br />PL.PLATE/PROPERTY LINE <br />P.LAM.PLASTIC LAMINTE <br />PLAS.PLASTER <br />PLUMB.PLUMBING <br />PLYWD PLYWOOD <br />PNT.PAINT <br />P.O.C.POINT OF CONNECTION <br />PR.PAIR <br />PROJ.PROJECTION <br />PSL.PARALLEL STRAND <br />LAMINATE <br />PT.POINT <br />R.A.RETURN AIR <br />RAD.RADIUS <br />R.D.ROOF DRAIN <br />R.D.L.ROOF DRAIN LEADER <br />RECPT.RECEPTACLE <br />RECT.RECTANGULAR <br />REF.REFERENCE <br />REFR/ R/F REFRIGERATOR <br />REG.REGISTER <br />REINF.REINFORCEMENT <br />REQ'D.REQUIRED <br />RESIL.RESILIENT' <br />RET.RETAIN(ING), RETURN <br />RM.ROOM <br />R.O.ROUGH OPENING <br />R.R.ROOF RAFTER <br />RWD.REDWOOD <br />S.SOUTH <br />S.A.SUPPLY AIR <br />S.C.SOLID CORE <br />S.C.D.SEAT COVER DISPENSER <br />SCHED.SCHEDULE <br />S.D.SUB DRAIN/ <br />SOAP DISPENSER <br />SEC.SECTION <br />SEL.SELECTED <br />SH.SHELF <br />SHT.SHEET <br />SHT'G.SHEATHING <br />SIM.SIMILAR <br />SIMP.SIMPSON <br />S.J.SOFFIT JOIST <br />S.S.STAINLESS STEEL <br />S.SK.SERVICE SINK <br />STA.STATION <br />STD.STANDARD <br />STL.STEEL <br />STOR.STORAGE <br />STRUCT.STRUCTURAL <br />SUSP.SUSPENDED <br />SYM.SYMMETRICAL <br />T.TREAD <br />T.C.TOP OF CURB <br />T.CL.TIME CLOCK <br />TEL.TELEPHONE <br />TEMP.TEMPERED <br />TER.TERRAZZO <br />T.D.TOP OF FENCE <br />T.&G.TONGUE AND GROOVE <br />THK. THICK <br />T.P.TOP OF PAVING <br />T.PL.TOP OF PLATE <br />T.O.S.TOP OF STRUCTURE/SLAB <br />TRANS.TRANSFORMER <br />T.S.TOP OF STEP <br />T.W.TOP OF WALL <br />TYP.TYPICAL <br />ABREVIATION <br />NORTH ARROW <br />BUILDING SECTIONSHEET NUMBER <br />SECTION NUMBER1 <br />A1.01 <br />BUILDING ELEVATION <br />SHEET NUMBER <br />ELEVATION NUMBER <br />A1.01 <br />1 <br />1 <br />A1.01 <br />DETAIL NUMBER <br />SHEET NUMBER <br />XX <br />DOOR TYPE <br />WINDOW TYPE <br />XX <br />KEY NOTE REFERENCE <br />STEP AS SLAB <br />DOOR ID <br />XX WINDOW ID <br />2" <br />SYMBOLS LEGEND <br />DETAIL REFFERENCE <br />REVISION REFERENCE1REVISION <br />NUMBER <br />KEYNOTE NUMBER <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />NEW DETACHED ADU <br />2 BEDS, 2 BATHS, <br />LIVING, KITCHEN, <br />DINING, LAUNDRY <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />1 11/25/2023 1ST PLANCHECK <br />2 12/21/2023 2ND PLANCHECK <br />A.03 <br />GENERAL DETAILS <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />14 <br />0 <br />2 <br /> <br />W <br /> <br />1 <br />0 <br />T <br />H <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SI <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />14 <br />0 <br />2 <br /> <br />W <br /> <br />1 <br />0 <br />T <br />H <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />ATTIC AIR HANDLER REQUIREMENTS <br />#GENERAL WINDOW NOTES <br />WATER HEATER <br />1402 W 10th St & Unit #2 - <br />101117923-245/8/2024