ELECTRIC OUTLET AND
<br />LIGHT FIXTURE
<br />20' MAX.
<br />30" MIN.
<br />MIN. 30X30" WORKING
<br />PLATFORM SECURED IN
<br />PLACE
<br />22x30" MIN.
<br />ATTIC ACCESS
<br />MIN. 24" WIDE SOLID
<br />FLOORING FROM ACCESS
<br />OPENING TO FURNACE
<br />WORKING PLATFORM
<br />LIGHT SWITCH
<br />30
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />30
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />ATTIC AIR HANDLER
<br />AIR HANDLER DISCONNECT
<br />AND ELECTRICAL OUTLET
<br />1. WINDOW MANUFACTURER AND INSTALLER SHALL INSURE THAT ALL WINDOWS MEET OR
<br />EXCEED ALL EGRESS REQUIREMENTS OF CRC R310 & R312
<br />2. ALL WINDOWS AND SLIDING GLASS DOORS SHALL BE INSTALLED PER AMERICAN
<br />ARCHITECTURAL MANUFACTURERS ASSOCIATION AAMA 2400=02 RECOMMENDATIONS
<br />"STANDARD PRACTICE FOR INSTALLATION OF WINDOWS WITH INTEGRAL MOUNTING
<br />FLANGES IN STUD FRAME CONSTRUCTION".
<br />3. INSTALL AN ISOLATION MEMBRANE BELOW THE THRESHOLD OF ALL SLIDING GLASS
<br />DOORS THAT REST ON A CONCRETE SLAB.
<br />4. ALL SEALANT SHALL BE OF HIGH QUALITY AND REVIEWED OFR COMPATIBILITY WITH
<br />ASPHALTIC MEMBRANES AND FLASHING MATERIAL.
<br />44" MAXIMUM
<br />24" MIN.
<br />20" MINNIMUM
<br />F.F. > 72" ABV. FINISH GRADE.
<br />24" MINIMUM @
<br />44" MAXIMUM
<br />20" MINNIMUM
<br />F.F. > 72" ABV. FINISH GRADE.
<br />24" MINIMUM @
<br />5.7 S.F MINIMUM
<br />24" MIN.
<br />5.
<br />7
<br />
<br />S
<br />.
<br />F
<br />
<br />M
<br />I
<br />N
<br />I
<br />M
<br />U
<br />M
<br />1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET.
<br />2. MIN. SET CLEAR HEIGHT OF 24 INCHES.
<br />3. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE
<br />FLOOR.
<br />EMERGENCY EGRESS
<br />WINDOW AND DOOR NOTE
<br />GENERAL NOTES
<br />1. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS
<br />EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR
<br />SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET
<br />FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE.
<br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING
<br />CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
<br />DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES
<br />BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY
<br />VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
<br />3. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS;
<br />FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY
<br />MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS.
<br />CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT
<br />SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY
<br />SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
<br />4. CONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP
<br />DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR.
<br />5. CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND
<br />CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK TOGETHER WITH ANY OTHER WORK
<br />WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND
<br />TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT
<br />MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT
<br />OR FOR LONGER PERIODS.
<br />6. THAT IS RESPONSIBILITY OF CONTRACTOR TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD
<br />OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS.
<br />7. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-
<br />CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF
<br />MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF
<br />SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF
<br />THE OWNER AND WITHOUT COST TO OWNER.
<br />8. THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER.
<br />ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER
<br />EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE
<br />RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR
<br />PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR
<br />EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK.
<br />ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO
<br />THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO
<br />RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
<br />9. OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING
<br />ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR. BEFORE ANY CHANGES ARE BEGUN, THE ADDED OR
<br />DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
<br />10. SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND
<br />SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN W RITING FOR APPROVAL OR DENIAL. IF MORE THAN ONE MANUFACTURER IS SPECIFIED IN
<br />THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR
<br />STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR
<br />ARCHITECT'S AND OWNER'S DECISION.
<br />11. THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND
<br />DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR
<br />MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR
<br />SUB-CONTRACTOR FINDS ANY DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT
<br />IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY
<br />OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND
<br />THOSE INDICATED ON THE DRAWINGS.
<br />12. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE
<br />IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED
<br />IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN
<br />DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD.
<br />13. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND
<br />DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND
<br />OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS
<br />AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY
<br />MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES.
<br />SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED
<br />PROCUREMENT, FABRICATION OR CONSTRUCTION.
<br />14. FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-
<br />CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR
<br />MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED
<br />IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR
<br />APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS.
<br />NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS.
<br />15. ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE
<br />IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF
<br />FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD
<br />RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND
<br />SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN
<br />BOTH.
<br />16. AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE
<br />STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE STRUCTURAL FRAME, SUB-
<br />CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH
<br />TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO
<br />FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER.
<br />CONTRACTOR AND HIS SUB-CONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR
<br />COMPONENT PARTS.
<br />17. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE
<br />APPEARS HERON.
<br />18. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
<br />19. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
<br />20. THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS,
<br />COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE
<br />ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED
<br />ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND
<br />MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE.
<br />21. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A
<br />CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE
<br />PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND
<br />MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER
<br />SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R-VALUE.
<br />22. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT.
<br />23. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND
<br />RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS
<br />PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.
<br />24. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS
<br />WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR INFORMATION
<br />APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HAND
<br />WRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION
<br />(PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING).
<br />U UNDER
<br />U.B.C.UNIFORM BUILDING CODE
<br />U.G.UNDERGROUND
<br />U.L.UNDERWRITER'S LABORATORY
<br />UNF.UNFINISHED
<br />U.N.O.UNLESS NOTED OTHERWISE
<br />UR.URINAL
<br />V.VERTICAL
<br />VENT.VENTILATING
<br />VERT.VERTICAL
<br />VER.VERIFY
<br />V.T.R.VENT THROUGH ROOF
<br />W.WEST, WIDE, WIDTH
<br />W/.WITH
<br />WD.WOOD
<br />W.H.WATER HEATER
<br />W.C.WATER CLOSET
<br />W.I.WROUGHT IRON
<br />WP.WATERPROOF
<br />W.W.M.WELDED WIRE MESH
<br />&AND
<br /><ANGLE
<br />@ AT
<br />C CENTERLINE
<br />∅DIAMETER OR ROUND
<br />PL PROPERTY LINE, PLATE
<br />A.B.ANCHOR BOLT
<br />ABV.ABOVE
<br />A/C AIR CONDITIONING
<br />A.C.ASPHALT CONCRETE
<br />ACOUS.ACOUSTICAL
<br />A.D.AREA DRAIN
<br />ADH.ADHESIVE
<br />ADJ.ADJUSTABLE
<br />AL.ALUMINUM
<br />ALT.ALTERNATE
<br />ANOD.ANODIZED
<br />A.P.ACCESS PANEL
<br />APPX.APPROXIMATELY
<br />APPV'D APPROVED
<br />ARCH.ARCHITECTURAL
<br />ASB.ASBESTOS
<br />ASSY.ASSEMBLY
<br />AUTO.AUTOMATIC
<br />B.BATH
<br />BD.BOADRD
<br />BEL.BELOW
<br />BET.BETWEEN
<br />BITUM.BITUMINOUS
<br />BLDG.BUILDING
<br />BLK.BLOCK
<br />BLK'G BLOCKING
<br />BM.BEAM
<br />B.O.BY OWNER/BY OTHERS
<br />BOT.BOTTOM
<br />BR.BEDROOM
<br />B.W.BACK OF WALK/
<br />BOT. OF WALL
<br />CAB.CABINET
<br />C.B.CATCH BASIN
<br />CEM.CEMENT
<br />C.G.CORNER GUARD
<br />CHAN.CHANNEL
<br />CHG.CHANGE
<br />C.I.CAST IRON
<br />C.J.CONTROL JOINT/
<br />CONST. JOINT
<br />CLG.CEILING/ CEILING JOIST
<br />CLKG.CAULKING
<br />CLR.CLEAR
<br />CNTR.COUNTER
<br />CONC.CONCRETE
<br />COND.CONDITION
<br />CONST.CONSTRUCTION
<br />CONT.CONTRACTOR/ CONTINOUS
<br />CORR.CORRIDOR, CORROSIVE
<br />CTSK.COUNTERSUNK
<br />CTR.CENTER
<br />DBL.DOUBLE
<br />DECO.DECORATIVE
<br />DEPT.DEPARTMENT
<br />DET.DETAIL
<br />D.F.DRINKING FOUNTAIN/
<br />DOUGLASS FIR
<br />DIA.DIAMETER
<br />DIAG.DIAGONAL
<br />DIM.DIMENSION
<br />DN.DOWN
<br />DR.DOOR
<br />D.S.DOWN SPOUT
<br />D.S.P.DRY STAND PIPE
<br />DWG.DRAWING
<br />(E.)EXISTING/ EAST/
<br />ENTRY/ EACH
<br />E.J.EXPANSION JOINT
<br />EL.ELEVATION
<br />ELEC.ELECTRIC
<br />ELEV.ELEVATOR
<br />EMER.EMERGENCY
<br />ENCL.ENCLOSURE
<br />E.P.ELECTRIC PANEL
<br />E.Q.EQUAL/
<br />EQUIVALENT
<br />EQPT/
<br />EQPM EQUIPMENT
<br />E.W.EACH WAY
<br />EXST.EXISTING
<br />EXH.EXHAUST
<br />EXPO.EXPOSED
<br />EXT.EXTERIOR
<br />E.G.EXISTING GRADE
<br />F.FIXED
<br />F.A.FIRE ALARM
<br />FAC.FACTORY
<br />F.C.O.FLOOR CLEAN OUT
<br />F.D.FLOOR DRAIN
<br />FDN.FOUNDATION
<br />F.E.FIRE EXTINGUISHER
<br />F.E.C.FIRE EXTINGUISHER CABINET
<br />F.G.FINISH GRADE
<br />F.H.FLAT HEAD
<br />FIN.FINISH
<br />FIX/FIXT FIXTURE
<br />F.J.FLOOR JOIST
<br />F.L.FLOW LINE
<br />FLASH.FLASHING
<br />FLR.FLOOR
<br />FLUOR.FLUORESCENT
<br />F.O.C.FACE OF CONCRETE/
<br />FACE OF CURB
<br />F.O.F.FACE OF FINISH
<br />F.O.S.FACE OF STUD/
<br />FACE OF STRUCUTRE
<br />F.O.M.FACE OF MASONRY
<br />FP.FIREPLACE
<br />F.S.FLOOR SINK
<br />FT.FOOT OR FEET
<br />FTG.FOOTING
<br />FURR.FURRING
<br />FUT.FUTURE
<br />F.V.FIELD VERIFY
<br />GA.GAUGE
<br />GALV.GALVANIZED
<br />G.B.GRAB BAR/GRADE BEAM
<br />G.C.GENERAL CONTRACTOR
<br />GEN.GENERAL
<br />G.F.I.GROUND FAULT INTERRUPT
<br />G.I.GALVANIZED IRON
<br />G.L.GLASS
<br />G.L.B.GLU-LAM BEAM
<br />GND.GROUND
<br />GR.GRADE
<br />GYP.GYPSUM
<br />G.P. GRADE PLANE
<br />H.HIGH
<br />H.B.HOSE BIB
<br />H.C.HOLLOW CORE
<br />HD.HARD
<br />HDR.HEADER
<br />HDWD.HARDWOOD
<br />HDWR.HARDWARE
<br />H.M.HOLLOW METAL
<br />HORIZ.HORIZONTAL
<br />HR.HOUR
<br />HT./HGT.HEIGHT
<br />HVAC HEATING VENTILATING/
<br />AIR COND.
<br />I.D.INSIDE DIAMETER/
<br />INTERIOR DESIGNER
<br />IN.INCH
<br />INSUL.INSULATION
<br />INT.INTERIOR
<br />INV.INVERT/
<br />INVERTED
<br />JAN.JANITOR
<br />JT.JOINT
<br />JST.JOIST
<br />KIT.KITCHEN
<br />L.LOW/LINEN
<br />L.A.LANDSCAPED AREA
<br />LAB.LABORATORY
<br />LAM.LAMINATE
<br />LAV.LAVATORY
<br />LBS.POUNDS
<br />LFA.LOAD FROM ABOVE
<br />L.H.LEFT HAND
<br />LKR.LOCKER
<br />LT.LIGHT
<br />LUM.LUMINOUS
<br />MAINT.MAINTENANCE
<br />MAS.MASONRY
<br />MAT.MATERIAL
<br />MAX.MAXIMUM
<br />M.B.METAL BOLT
<br />M.C.MEDICINE CABINET
<br />MECH.MECHANICAL
<br />MEMB.MEMBRANE
<br />MET/MTL.METAL
<br />MFR/MFGR MANUFACTURER
<br />M.H.MAN HOLE
<br />MIN.MINIMUM
<br />MIR.MIRROR
<br />MISC.MISCELLANEOUS
<br />M.O.MASONRY OPENING
<br />MOS.MOSAIC
<br />MTD.MOUNTED
<br />MUL.MULLION
<br />(N.)NEW
<br />N.NORTH
<br />NAT.NATURAL
<br />N.I.C.NOT IN CONTRACT
<br />N.G.NATURAL GRADE
<br />NO.NUMBER
<br />NOM.NOMINAL
<br />N.T.S.NOT TO SCALE
<br />O/.OVER
<br />O.A.OVERALL
<br />OBS.OBSCURE
<br />O.C.ON CENTER
<br />O.D.OUTSIDE DIAMETER/
<br />DIMENSION
<br />O.F.D.OVERFLOW DRAIN
<br />OFF.OFFICE
<br />OPNC.OPENING
<br />OPP.OPPOSITE
<br />PERIM.PERIMETER
<br />PL.PLATE/PROPERTY LINE
<br />P.LAM.PLASTIC LAMINTE
<br />PLAS.PLASTER
<br />PLUMB.PLUMBING
<br />PLYWD PLYWOOD
<br />PNT.PAINT
<br />P.O.C.POINT OF CONNECTION
<br />PR.PAIR
<br />PROJ.PROJECTION
<br />PSL.PARALLEL STRAND
<br />LAMINATE
<br />PT.POINT
<br />R.A.RETURN AIR
<br />RAD.RADIUS
<br />R.D.ROOF DRAIN
<br />R.D.L.ROOF DRAIN LEADER
<br />RECPT.RECEPTACLE
<br />RECT.RECTANGULAR
<br />REF.REFERENCE
<br />REFR/ R/F REFRIGERATOR
<br />REG.REGISTER
<br />REINF.REINFORCEMENT
<br />REQ'D.REQUIRED
<br />RESIL.RESILIENT'
<br />RET.RETAIN(ING), RETURN
<br />RM.ROOM
<br />R.O.ROUGH OPENING
<br />R.R.ROOF RAFTER
<br />RWD.REDWOOD
<br />S.SOUTH
<br />S.A.SUPPLY AIR
<br />S.C.SOLID CORE
<br />S.C.D.SEAT COVER DISPENSER
<br />SCHED.SCHEDULE
<br />S.D.SUB DRAIN/
<br />SOAP DISPENSER
<br />SEC.SECTION
<br />SEL.SELECTED
<br />SH.SHELF
<br />SHT.SHEET
<br />SHT'G.SHEATHING
<br />SIM.SIMILAR
<br />SIMP.SIMPSON
<br />S.J.SOFFIT JOIST
<br />S.S.STAINLESS STEEL
<br />S.SK.SERVICE SINK
<br />STA.STATION
<br />STD.STANDARD
<br />STL.STEEL
<br />STOR.STORAGE
<br />STRUCT.STRUCTURAL
<br />SUSP.SUSPENDED
<br />SYM.SYMMETRICAL
<br />T.TREAD
<br />T.C.TOP OF CURB
<br />T.CL.TIME CLOCK
<br />TEL.TELEPHONE
<br />TEMP.TEMPERED
<br />TER.TERRAZZO
<br />T.D.TOP OF FENCE
<br />T.&G.TONGUE AND GROOVE
<br />THK. THICK
<br />T.P.TOP OF PAVING
<br />T.PL.TOP OF PLATE
<br />T.O.S.TOP OF STRUCTURE/SLAB
<br />TRANS.TRANSFORMER
<br />T.S.TOP OF STEP
<br />T.W.TOP OF WALL
<br />TYP.TYPICAL
<br />ABREVIATION
<br />NORTH ARROW
<br />BUILDING SECTIONSHEET NUMBER
<br />SECTION NUMBER1
<br />A1.01
<br />BUILDING ELEVATION
<br />SHEET NUMBER
<br />ELEVATION NUMBER
<br />A1.01
<br />1
<br />1
<br />A1.01
<br />DETAIL NUMBER
<br />SHEET NUMBER
<br />XX
<br />DOOR TYPE
<br />WINDOW TYPE
<br />XX
<br />KEY NOTE REFERENCE
<br />STEP AS SLAB
<br />DOOR ID
<br />XX WINDOW ID
<br />2"
<br />SYMBOLS LEGEND
<br />DETAIL REFFERENCE
<br />REVISION REFERENCE1REVISION
<br />NUMBER
<br />KEYNOTE NUMBER
<br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO
<br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY
<br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A
<br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND
<br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL
<br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE
<br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS
<br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR
<br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED.
<br />DESCRIPTIONDATEDELTA
<br />NEW DETACHED ADU
<br />2 BEDS, 2 BATHS,
<br />LIVING, KITCHEN,
<br />DINING, LAUNDRY
<br />PROJECT CONTACT
<br />OWNERSHIP
<br />KHANH DAO
<br />10448 SALINAS RIVER CIR
<br />FOUNTAIN VALLEY, CA 92708
<br />PHONE: (714) 390-5154
<br />LOAN PHAM
<br />17021 BOLERO LN
<br />HUNTINGTON BEACH, CA 92649
<br />PHONE: 714-614-6344
<br />EMAIL: LOANPHAM8888@YAHOO.COM
<br />1 11/25/2023 1ST PLANCHECK
<br />2 12/21/2023 2ND PLANCHECK
<br />A.03
<br />GENERAL DETAILS
<br />(N
<br />)
<br />
<br />D
<br />E
<br />T
<br />A
<br />C
<br />H
<br />E
<br />D
<br />
<br />A
<br />D
<br />U
<br />14
<br />0
<br />2
<br />
<br />W
<br />
<br />1
<br />0
<br />T
<br />H
<br />
<br />S
<br />T
<br />,
<br />
<br />U
<br />N
<br />I
<br />T
<br />
<br />2
<br />,
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />SI
<br />N
<br />G
<br />L
<br />E
<br />
<br />F
<br />A
<br />M
<br />I
<br />L
<br />Y
<br />
<br />R
<br />E
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />14
<br />0
<br />2
<br />
<br />W
<br />
<br />1
<br />0
<br />T
<br />H
<br />
<br />S
<br />T
<br />,
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />ATTIC AIR HANDLER REQUIREMENTS
<br />#GENERAL WINDOW NOTES
<br />WATER HEATER
<br />1402 W 10th St & Unit #2 -
<br />101117923-245/8/2024
|