Laserfiche WebLink
AT <br />T <br />I <br />C <br />HP <br />W/H <br />RE <br />F <br />GAS <br />DW <br />W <br />D <br />HP <br />ATTIC <br />RE <br />F <br />GAS <br />DW <br />W <br />D <br />1. VERIFY ALL APPLIANCE EQUIPMENT AND FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO CASEWORK <br />FABRICATION INSTALLATION. <br />2. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & PAINT EXPOSED GYP. BD. WALL TO <br />MATCH WALLS. INSTALL MATCHING BASE BD. <br />3. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. <br />4. SHOWER COMPARTMENTS AND WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A <br />SMOOTH, NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. <br />5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. <br />6. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING FINISH. <br />7. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE HARD WIRED WITH BATTERY <br />BACK-UP AND LOCATED (1) IN EACH BEDROOM, HALLWAYS OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR <br />ALARM SOUND MUST BE AUDIBLE IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE DETECTORS WITHIN <br />THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. INSTALL AND LOCATE PER MFGR. LISTED REQUIREMENTS. <br />8. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE SLEEPING ROOMS PER CHAPTER 3 CRC. <br />9. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE DUCTED TO THE EXTERIOR OF THE <br />BUILDING <br />10. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD REQUIREMENTS. <br />11. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. <br />12. PROVIDE TWO LAYERS OF GRADE D OR 60-MINUTE GRADE D PAPER OVER ALL WOOD BASE SHEATHING AT EXTERIOR WALLS. <br />13. A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL FLANGE OF 3½ <br />INCHES SHALL BE PROVIDED AT OR BELOW FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS. SCREED SHALL BE A <br />MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1) <br />14. ACCESS TO ATTIC FURNACE MUST BE WITHIN 20' OF UNIT AND SHALL HAVE A CONTINUOUS SOLID WALKWAY AT LEAST 24" <br />WIDE. A SWITCH CONTROL IS ALSO REQUIRED (CMC 304.4.1) <br />15. DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH <br />OF 14 FEET (4267 MM), INCLUDING TWO 90 DEGREE (1.57 RAD) ELBOWS.A LENGTH OF 2 FEET (610 MM) SHALL BE DEDUCTED <br />FOR EACH 90 DEGREE (1.57 RAD) ELBOW IN EXCESS OF TWO. <br />16. ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED WATER HEATING SYSTEM, SHALL HAVE: <br />(BEES 150.0(N)1A-D) <br />A. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER. <br />B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. <br />C. CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. <br />17. SMOKE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVE ALL ALARMS. <br />18. CARBON MONOXIDE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVE ALL <br />ALARMS. <br />KITCHEN EXHAUST FAN 85% CE OR 280 CFM SHALL BE <br />DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />(N) 2X4 WALL <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING <br />MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ <br />HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% SHALL <br />BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />IAQ FAN MIN 46 CFM PER T-24 <br />PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, <br />MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE <br />HB <br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR <br />SMOKE DETECTOR HARDWIRED w/ <br />BATTERY BACK UP <br />SD <br />CARBON MONOXIDE DETECTOR ALARM <br />HARDWIRED w/ BATTERY BACK UPCD <br />24X30 ATTIC ACCESS <br />HEATPUMP + AIR <br />HANDLER <br />HEATPUMP UNIT ON <br />PAD 3" MIN. <br />ELECTRIC WATER <br />HEATER W/ HEATPUMP <br />1-HOUR FIRE RATED WALL <br />LAUNDRY DRYER EXHAUST <br />CEILING AIR DIFFUSER <br />ELECTRICAL PANEL/METER PER KEYNOTE <br />WHOLE HOUSE FAN: 1200 CFM PER T-24 <br />1 <br />DUAL-GANG ELECTRICAL METER BOX1.1 <br />ELECTRICAL SUB-PANEL 225 AMP <br />2 CONSUMER TANK W/ HEATPUMP <br />3 24X30 ATTIC ACCESS <br />4 LANDING. 1 1/2" BELOW THRESHOLD.MINIMUM 36" IN <br />DEPTH.MIN. 2% SLOPE AWAY FROM BUILDING. <br />5 <br />EXHAUST FAN FOR BATHROOM SHALL BE ENERGY STAR <br />RATED. CEILING MOUNTED LIGHT W/VENT 50CFM MIN. <br />INTERMITTENT W/HUMIDITY CONTROL PER CMC402.5, <br />BETWEEN 50-80% SHALL BE DUCTED TO OUTSIDE <br />THROUGH ROOF/ EXTERIOR WALL. <br />6 HEATPUMP UNIT ON 3" THICK CONCRETE PAD <br />8 OBSCURED,TEMPERED GLASS <br />9 <br />10 <br />7 <br />LOUVER DOOR TO PROVIDE 100SQ.IN MAKE-UP AIR <br />TEMPERED GLASS <br />FUTURE INSTALLED FLOOR MOUNTED <br />FOLDABLE GRAB BAR <br />APPROVED PRE-FABRICATED SHOWER <br />ENCLOSURES WALL PANELS WITH FACTORY- <br />INSTALLED REINFORCEMENT FOR GRAB BARS. <br />11 <br />12 <br />1HR FIRE RATED WALL, SEE DETAIL #18/ AD.10 <br />UNPROTECTED OPENING MAX 25% WALL AREA <br />2X8 BACKING FOR FUTURE GRAB BAR <br />INSTALLATION <br />2'' SHOWER CURB. <br />EXHAUST FAN ABOVE GAS RANGE SHALL BE 85% <br />CE OR 280 CFM (EXHAUST THROUGH WALL)13 <br />14 <br />15 <br />16 <br />MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A <br />BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS <br />LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] <br />(EXHAUST THROUGH EXTERIOR WALL) <br />XX DOOR TYPE, SEE SCHEDULE <br />WINDOW TYPE, SEE SCHEDULE <br />XX KEY NOTE <br />FLOOR DEPRESSION <br />XX <br />6" <br />15 <br />" <br />15 <br />" <br />8'-1"8'-0 1/2"2'-4 1/2"5'-4"5'-3 1/2" <br />29 1/2" <br />29'-1" <br />11'-0" <br />9'-11" <br />11'-1" <br />10'-0" <br />3'-0"3'-0" <br />4'-0" <br />2'-6" <br />2'-6" <br />10'-3" <br />5'-0 1/2" <br />6'-2 1/2" <br />5'-10" <br />A.06 <br />3 <br />13'-0 1/2"5'-0"11'-0 1/2" <br />ENTRY PORCH 60 SF <br />4'-9" <br />5'-3" <br />4'-11 1/2" <br />8'-11" <br />2'-6 1/2" <br />5'-8" <br />27'-4" <br />3 <br />2 <br />3 3 <br />B B <br />A <br />B <br />4 <br />4 <br />6A <br />A <br />1 <br />C <br />5 <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />BED 1 <br />10FT CL'G <br />BED 2 <br />10FT CL'G <br />BATH 1 <br />10FT CL'G <br />BATH 2 <br />10FT CL'G <br />HALLWAY <br />LIVING <br />10FT CL'G <br />KITCHEN <br />10FT CL'G <br />A.06 <br />1 <br />A <br />A.06 <br />A <br />A.06 <br />16'-7 1/2" <br />3'-0" <br />16"16" <br />28 <br />" <br />6x6 POST 6x6 POST <br />B <br />A.06 <br />B <br />A.06 <br />A. <br />0 <br />6 <br />2 <br />A. <br />0 <br />6 <br />4 <br />1 1.1 <br />SD <br />SD <br />SD <br />CD <br />HB <br />HB <br />1. <br />5 <br />" <br />EE <br />& <br />R <br />O <br />EE&RO <br />8 <br />12 <br />1616 <br />8 <br />7 <br />11 <br />7 <br />11 <br />14 <br />15 <br />13 <br />5 <br />4 <br />7 <br />10 <br />9 <br />6 <br />10 <br />2 <br />3 <br />RANGEHOOD TO OUTSIDE <br />DRYER EXHAUST TO OUTSIDE <br />2'-0" <br />3'-7" <br />1' <br />- <br />0 <br />" <br />A <br />12 <br />5'-1" <br />2'-6" <br />16 <br />AD.10 <br />A.06 <br />3 <br />4:12 <br />4:12 <br />4:12 <br />4:12 <br />4:12 <br />PORCH BELOW <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />WALL LINE BELOW <br />WALL LINE BELOW <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />(N) ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY <br />CERTAINTEED ICC-ESR #3537.OVER 30# BUILDING PAPER OVER <br />PLYWOOD SHEATHING OVER RADIANT BARRIER OVER RAFTERS <br />PER STRUCTURAL DWGS. ROOF COLOR AND MATERIAL TO <br />MATCH WITH EXISTING BUILDING. <br />SO <br />L <br />A <br />R <br /> <br />P <br />A <br />N <br />E <br />L <br />S <br />O'HAGIN 72 SQ.IN, TYP. <br />A.06 <br />1 <br />A <br />A.06 <br />A <br />A.06 <br />B <br />A.06 <br />B <br />A.06 <br />A. <br />0 <br />6 <br />2 <br />A. <br />0 <br />6 <br />4 <br />ROOF ATTIC <br />800 SF <br />17 <br />AD.10 <br />3'-0" <br />3'-6 <br />" <br />3'-6 <br /> <br />1/2" <br />9 <br />AD.10 <br />17 <br />AD.10 <br />R327.1.1 REINFORCEMENT FOR GRAB BARS <br />AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN <br />ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE <br />BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING <br />AGENCY. <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 <br />INCH (38 MM BY 184 MM) ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND <br />LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) AND 39 1/4 INCHES (997 MM) <br />ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. <br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL <br />AND THE BACK WALL. <br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE <br />BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE <br />PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. <br />EXCEPTIONS <br />1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A <br />GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, <br />FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING <br />AGENCY. <br />2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PREFABRICATED SHOWER <br />ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORYINSTALLED GRAB BARS OR WHEN <br />FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS <br />SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS <br />OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />4. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION <br />OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR- <br />MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE <br />ENFORCING AGENCY. <br />5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED <br />ON CONCRETE SLAB FLOORS. <br />R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS <br />ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING <br />CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDEDTO BE <br />USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES (1219.2 MM) <br />MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES <br />(381 MM) MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH <br />FLOOR. <br />EXCEPTIONS <br />1. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS <br />MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON <br />APPLIANCES. <br />2. RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON <br />A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED FLOOR AND A <br />BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW, IS LESS <br />THAN 15 INCHES (381 MM) <br />R327.1.3 INTERIOR DOORS <br />EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY <br />LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF OR LESS THAN 32 <br />INCHES (812.8 MM), MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES <br />FROM THE CLOSED POSITION; OR, IN THE CASE OF A TWO OR THREE-STORY SINGLE <br />FAMILY DWELLING, ON THE SECOND OR THIRD FLOOR OF THE DWELLING IF A BATHROOM <br />OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. <br />R327.1.4 DOORBELL BUTTONS <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES <br />(1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE <br />DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER <br />FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED <br />FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL <br />SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE <br />EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR <br />CONTROL. <br />AGING-IN PLACE NOTES <br />1. ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537. COLOR & PER <br />THE INSTALLATION OF ROOF COVERING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. <br />2. PROJECTIONS LESS THAN 5'-0" (HOUSE WITH NO SPRINKLER) TO PROPERTY LINE TO BE 1-HOUR <br />CONSTRUCTION, TYP. <br />3. ROOF VENT : SEE ROOF VENTILATION CALCULATION. <br />ATTIC AREA: 800 SF <br />USE BALANCE METHOD : <br />NET VENT AREA REQUIRE : 800/300 x 144 SQ.IN. = 384 SQ.IN <br />WHOLE HOUSE FAN: 1200 CFM -230 SQ.IN VENT NFA IS REQUIRED (144 SQ.IN PER 750 CFM) <br />TOTAL VENT AREA REQUIRED: 384 + 230 = 614 SQ.IN <br />NOTE: MAX. 50% ON UPPER ROOF AREA <br />LOW: USE 5 UNITS O'HAGIN VENT (72 SQ.IN/UNIT) (1/3 LOW AREA OF ROOF) <br />HIGHT: USE 4 UNITS O'HAGIN VENT (72 SQ.IN/UNIT) (1/3 HIGH AREA OF ROOF) <br />DOOR/WINDOW REMARKS: <br />(1) DOOR SHALL HAVE A MINIMUM CLEAR WIDTH OF 32" WHEN MEASURED BETWEEN THE FACE OF THE <br />DOOR AND THE STOP,WITH THE DOOR OPEN AT 90 DEGREE. <br />(2) DOOR SHALL HAVE A MINIMUM CLEAR HEIGHT OF 78", MEASURED FROM THE TOP OF THE THRESHOLD TO <br />THE BOTTOM OF THE STOP <br />(3) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR <br />SPECIAL KNOWLEDGE OR EFFORT. <br />(4) SELF-CLOSING, TIGHT FITTING, SOLID WOOD, 1-3/8'' THICK DOOR, NOT LESS THAN 20-MIN FIRERATED <br />DOOR AT OPENING TO DWELLING (CBC 715.4.3). <br />(5) MIN. 72'' ABOVE FINISH FLOOR IN BATHROOMS. <br />(6) THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED <br />BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE ENERGY <br />CALCULATIONS. <br />(7) THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN <br />ACCORDANCE WITH ASTM E1300. <br />(8) ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, ASER- <br />ETCHED, OR EMBOSSED PER CRC 2406.3. <br />(9) DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE <br />(10) GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR <br />PRIVATE AREA <br />435 SF <br />45:55 RATIO OF COMMON TO PRIVATE AREAS <br />COMMON AREA <br />355 SF <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />NEW DETACHED ADU <br />2 BEDS, 2 BATHS, <br />LIVING, KITCHEN, <br />DINING, LAUNDRY <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />1 11/25/2023 1ST PLANCHECK <br />2 12/21/2023 2ND PLANCHECK <br />A.05 <br />PROPOSED FLOOR <br />PLAN & ROOF PLAN <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />14 <br />0 <br />2 <br /> <br />W <br /> <br />1 <br />0 <br />T <br />H <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SI <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />14 <br />0 <br />2 <br /> <br />W <br /> <br />1 <br />0 <br />T <br />H <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />FLOOR PLAN KEYNOTES <br />FLOOR PLAN LEGEND <br />FLOOR PLAN NOTES <br />1/4" = 1'-0"1ADU FLOOR PLAN 1/4" = 1'-0"2ADU ROOF PLAN <br />DOOR SCHEDULE <br />NUMBER DOOR SIZE QTY DESCRIPTION U-FACTOR SHGC REMARKS <br />1 3' - 0" x 6' - 8" 1 EXTERIOR DOOR 1 PANEL/TEMPERED GLASS, VINYL FRAME, <br />PAINTED FINISH <br />0.5 ENTRY DOOR (1), (2), (3), (9) <br />2 3' - 0" x 6' - 8" 1 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR <br />3 2' - 8" x 6' - 8" 3 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR <br />4 5' - 0" x 6' - 8" 2 INTERIOR SLIDING CLOSET INTERIOR <br />5 4' - 8" x 6' - 8" 1 HOLLOW CORE 2 PANELS, WOOD FRAME, PAINTED FINISH PROVIDE 100SQ.IN AIR GRILL <br />TO MAKE UP AIR <br />6 2' - 4" x 6' - 8" 1 STEEL DOOR LOUVER, PAINTED FINISH INTERIOR <br />Grand total: 9 <br />WINDOW SCHEDULE <br />ID QTY WINDOW SIZE DESCRIPTION U-FACTOR SHGC REMARKS <br />A 4 3' - 0" x 5' - 0" SINGLE HUNG, DUAL GLASS/ VINYL FRAME, FINISH PER MFGR. 0.3 0.23 <varies> <br />B 3 3' - 0" x 4' - 0" SINGLE HUNG, DUAL GLASS/ VINYL FRAME, FINISH PER MFGR. 0.3 0.23 <varies> <br />C 1 3' - 0" x 3' - 0" SINGLE HUNG, DUAL GLASS/ VINYL FRAME, FINISH PER MFGR. 0.3 0.23 <br />Grand total: 8 <br />ROOF PLAN GENERAL NOTES ROOF VENTILATION CALCULATION <br />AREA PLAN RATIO <br />1402 W 10th St & Unit #2 - <br />101117923-245/8/2024