GRAVEL BASE <br />10 MIL POLY VAPOR DIFFUSION <br />RETARDER IS EXTENTED UNDER <br />FOOTING <br />MORTAR BED 3/4" TO 1 1/4" <br />CONCRETE SLAB <br />BOND COAT <br />CERAMIC TILE <br />7/8" 3-COATS STUCCO/ OVER <br />METAL LATH <br />2 LAYERS OF GRADE "D" <br />BUILDING PAPER <br />(VAPOR BARRIER) <br />PLYWOOD SHEATHING (PER <br />STRUCTURAL DESIGN) MIN. MIN. <br />3/8" CDX PLYWOOD <br />2X FRAMING <br />INSULATION PER T-24 <br />1/2" GYPSUM BOARD <br />INTERIOR FINISH PER <br />SCHEDULE <br />EXTERIOR INTERIOR <br />1/2" GYPSUM BOARD <br />INTERIOR FINISH PER <br />SCHEDULE <br />INTERIOR INTERIOR <br />FIN. SLAB PER PLAN <br />POLYVINYL-CHLORIDE COATED <br />STEEL SPIRAL DUCT SIZE PER <br />MECHANICAL ENGINEER W/ <br />ALL JOISTS TAPED AND <br />SEALED <br />ANY AND ALL DUCK PENETRATIONS <br />TO BE ABOVE 9.00 NAVD88 <br />0' - 4" <br />0' - 4" <br />VAPOR BARRIER <br />4" MIN. CONCRETE <br />SURROUND ALL DUCTS <br />GRAVEL FILL <br />WHEN WALL IS SHEATHED ON THE <br />EXTERIOR, LAP BOTH LAYERS OF <br />BUILDING PAPER OVER THE WEEP <br />SCREED FLANGE <br />EXPOSED EARTH <br />MIN. 26 GA. G.S. PLASTER WEEP <br />SCREED W/ 3-1/2" VERTICAL <br />NAILING FLANGE <br />STUCCO OVER 1 <br />LAYER GRADE 'D' <br />PAPER <br />PRESSURE TREATED WOOD PLATE <br />SEAL TO CONCRETE W/ CONT. <br />BEAD OF SEALANT <br />WHEN WALL IS SHEATHED ON THE <br />EXTERIOR, LAP BOTH LAYERS OF <br />BUILDING PAPER OVER THE WEEP <br />SCREED FLANGE <br />CONC. SLAB <br />FOOTING OR <br />CURB <br />CONCRETE OR <br />IMPERVIOUS SURFACE <br />MIN. 26 GA. G.S. PLASTER WEEP <br />SCREED W/ 3-1/2" VERTICAL NAILING <br />FLANGE <br />STUCCO OVER 1 <br />LAYER GRADE 'D' <br />PAPER <br />PRESSURE TREATED WOOD PLATE <br />SEAL TO CONCRETE W/ CONT. BEAD <br />OF SEALANT <br />CONC. SLAB <br />FOOTING OR <br />CURB <br />5% <br />4'' MIN. <br />TO FIN. NATURAL GRADE <br /> 8 <br />'' MIN. <br />2'' MIN. <br />2% <br />TO FIN. NATURAL GRADE <br />8" MIN. <br />FLOOR FINISH, SEE <br />SCHEDULE <br />SEE STRUCT. DWGS FOR <br />SLAB UNDER LAYER <br />FACE OF STUD <br />PORCH SLAB2" <br />ISOLATED SLAB FROM <br />CONC. SEE STRUCT. <br />SLAB AND UNDER LAYER SEE <br />STRUCT. DWGS <br />INTERIOR FINISH, SEE <br />SCHEDULE <br />INTERIOR FINISH, <br />SEE SCHEDULE <br />2x STUD WALL <br />FLOOR FINISH, SEE <br />SCHEDULE <br />PORCH BEAM, SEE STRUCT. DWGS <br />SOFFIT BOARD <br />(EXTERIOR GRADE) <br />ROOF FRAMING <br />ROOF SHEATHING <br />CLASS ''A'' ROOFING <br />OVER 30# FELT <br />BOXED OUT SOFFIT <br />SOFFIT FRAMING <br />2" X 4" WOOD STUDS AT 16" WITH DOUBLE TOP PLATES, SINGLE BOTTOM PLATE; INTERIOR <br />AND EXTERIOR SIDES COVERED WITH TYPE X GYPSUM WALLBOARD AND SHEATHING, <br />RESPECTIVELY, 4' WIDE, APPLIED HORIZONTALLY OR VERTICALLY WITH VERTICAL JOINTS <br />OVER STUDS, AND FASTENED WITH 2 1/4" TYPE S DRYWALL SCREWS, SPACED 12" ON <br />CENTER. CAVITY TO BE FILLED WITH 3 1/2" " MINERAL WOOL INSULATION. PER CBC TABLE <br />721.1(2) ITEM 15-1.15 <br />7/8" 3-COATS STUCCO OVER <br />METAL LATH/WALL SIDING <br />WHERE OCCUR. <br />1 LAYER OF GRADE "D" BUILDING <br />PAPER <br />(VAPOR BARRIER) <br />PLYWOOD SHEATHING (PER <br />STRUCTURAL DESIGN) MIN. MIN. <br />3/8" CDX PLYWOOD <br />2X FRAMING <br />INSULATION PER T-24 <br />CAUKLING <br />ROOF RAFTER 2x FULL HEIGH FIRE BLOCK <br />NO VENT HOLE ALLOWED <br />SOLID FASCIA <br />MIN. <br />3 1/2" <br />MIN. <br />1". <br />@ paved <br />2" min. <br />@ N.G <br />6" min. <br />SLOPE 5% MIN. AT N.G <br />SLOPE 2% MIN. AT PAVED <br />PER. PLAN <br />CBC TABLE 721.1(2) ITEM 15-1.15 <br />CLASS I OR II VAPOR <br />RETARDER <br />INSTALLED ON THE <br />WARM IN WINTER <br />SIDE OF CEILING <br />VAULTED <br />CEILING WHERE <br />OCCUR <br />5/8" TYPE "X" GYP. SHEATHING <br />FOR OVERHANGE <br />SEE DETAIL 17 <br />ROOFING (SEE PLAN) OVER 2 LAYERS 30# BUILDING <br />PAPER OVER ROOF SHEATHING OVER RADIANT BARRIER <br />OVER ROOF FRAMING <br />1 LAYER OF 5/8" TYPE "X" <br />GYPSUM BOARD <br />10 <br />AD.10 <br />1-HOUR RATED <br />CEILING <br />1 <br />SEE PLAN <br />ROOFING (SEE PLAN) OVER 2 LAYERS 30# <br />BUILDING PAPER OVER ROOF SHEATHING <br />OVER RADIANT BARRIER OVER ROOF <br />FRAMING <br />2X BLK'G <br />GUTTER <br />WHERE <br />OCCURS <br />1x4 OVER 2x6 <br />FASCIA <br />1X4 ''V'' GROOVE T+G SOFFIT <br />OVER 5/8'' TYPE 'X' GYP. BD WHEN <br />LESS THAN 5'-0" TO PROPERTY LINE <br />2X6 FRIEZE OVER HOUSEWRAP <br />CAULK <br />EXT . MATERIAL OVER <br />HOUSEWRAP <br />COPPER FLASHING <br />5/8" GYP. SEE FINISH <br />SCHEDULE <br />1/2" GYP. WHERE SLOPE <br />CEILING OCCURS. <br />ATTIC SPACE <br />IN ROOM <br />WOOD JOIST, GYPSUM WALLBOARD <br />ONE LAYER OF 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER <br />BASE SHALL BE INSTALLED PERPENDICULAR TO THE CEILING FRAMING <br />AND SHALL BE FASTENED AT MAXIMUM 6 INCHES O.C. BY MIN. I 7/8 <br />INCHES 6D COATED NAILS OR EQUIVALENT DRYWALL SCREWS <br />REQ'D FIRE BARRIER CRC SEC. R302.6 <br />OCCUPANCY SEPARATION <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />NEW DETACHED ADU <br />2 BEDS, 2 BATHS, <br />LIVING, KITCHEN, <br />DINING, LAUNDRY <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />1 02/01/2024 1ST PLAN CORRECTION <br />AD.10 <br />ARCHITECTURAL <br />DETAILS <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />14 <br />0 <br />2 <br /> <br />W <br /> <br />1 <br />0 <br />T <br />H <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SI <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />14 <br />0 <br />2 <br /> <br />W <br /> <br />1 <br />0 <br />T <br />H <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />N/A 6VENT THROUGH ROOF <br />N/A 8CERAMIC TILE / CONCRETE <br />N/A 11DOOR HEAD/JAM <br />N/A 12DOOR JAM AT EXT. WALL <br />N/A 13WINDOW HEAD-STUCCO <br />N/A 14WINDOW JAM-STUCCO <br />N/A 15WINDOW SILL <br />N/A 1EXTERIOR WALL <br />1" = 1'-0"3INTERIOR WALL <br />N/A 4UNDER SLAB DUCT SYSTEM <br />N/A 5WEEP SCREET <br />N/A 2HOUSE TO PORCH <br />N/A 7NON-BEARING WALL <br />N/A 9PORCH CEILING SOFFIT <br />N/A 161HR EXT. WALL AND ROOF OVERHANG <br />N/A 17EAVE DETAIL <br />N/A 101-HOUR RATED CEILING <br />1 <br />1402 W 10th St & Unit #2 - <br />101117923-245/8/2024