Laserfiche WebLink
TIGO <br />EI INVERTER <br />PV INPUT BATTERY AC GRID <br />MPPT2 +-G L1L2NGG <br />(N) TIGO TSI-3.8K-US <br />INVERTER <br />(N) TIGO CCA <br />KIT <br />+ <br />RA485 <br />LAN <br />- <br />E-STOP <br />BUTTON <br />3 <br />(N) 9 JA SOLAR JAM54S31-395/MR (395W) WITH TIGO <br />TS4-A-O OPTIMIZER ATTACHED TO THE BACK OF EACH <br />MODULE <br />G <br />1 <br />(N) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE 2 <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />PV CIRCUIT 1: 9 MODULES/SERIES <br />MPPT1 <br />BACKFEED <br />BREAKER <br />M <br />POINT OF <br /> DELIVERY AND <br />INTERCONNECTION <br />200A <br />N <br />(E) GROUNDING <br />ELECTRODE OR <br />(UFER) <br />EXISTING <br />240V/200A <br />MAIN SERVICE PANEL <br />SINGLE PHASE <br />40A <br />AC DISCONNECT <br />TO BE LOCATED <br />WITHIN 10' OF <br />METER <br />(N) VISIBLE <br /> LOCKABLE <br />2 POLE 60A <br />'KNIFE' AC <br /> DISCONNECT <br />4 <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL <br />20A <br />15A <br />N <br />(N) 100A PV LOAD <br />CENTER <br />4 <br />AC DISCONNECT <br />TO BE LOCATED <br />WITHIN 10' OF <br />METER <br />(E) JUNCTION BOX WITH <br />IRREVRESIBLE GROUND <br />SPLICE <br />(E) 8 HYUNDAI M250ORG (250W) MODULES WITH <br />AN ENPHASE M215-IG MICRO-INVERTER <br />ATTACHED TO THE BACK OF EVERY MODULE. <br />RO <br />O <br />F <br /> <br />T <br />O <br />P <br />GR <br />O <br />U <br />N <br />D <br /> <br />L <br />E <br />V <br />E <br />L <br /> <br />- <br />HO <br />U <br />S <br />E <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br />EXISTING WIRE <br />8 <br />PV CIRCUIT 1: 8 MODULES/PARALLEL <br />12 <br />15A <br />N <br />(E) 100A PV LOAD <br />CENTER <br />(E) VISIBLE <br />LOCKABLE <br />2 POLE 30A <br />'KNIFE' AC <br /> DISCONNECT <br />EXISTING WIRE <br />(E) PV SYSTEM IS RSD COMPLIANT <br />EXISTING WIRE <br />EXISTING WIRE <br />RO <br />O <br />F <br /> <br />T <br />O <br />P <br />GR <br />O <br />U <br />N <br />D <br /> <br />L <br />E <br />V <br />E <br />L <br /> <br />- <br />HO <br />U <br />S <br />E <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br />1410 N PARSONS PL, <br /> SANTA ANA, <br /> CA 92703 <br />APN:10046201 <br />DATE:11/2/2023 <br />KINGSTON <br />RESIDENCE <br />License#: C-10 1053344 <br />ADDRESS:2072 N MAIN ST <br /> FL 2, LOGAN <br /> UT 84341-1993 <br /> CSLB#: 1053344 <br />DESIGNER: OAV <br />CORE ENERGY GROUP. <br />E-1.1 <br />METER # 222012785226 <br />MAIN SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 200A <br />MAX BREAKER SIZE: <br />(200A X 1.2) - 200A = 40.0A <br />1410 N Parsons Pl - <br />2018164112/13/2023