Laserfiche WebLink
1.NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD <br />REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. <br />2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE <br />3.ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE <br />PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP <br />RIVETS OR SCREWS OR OTHER APPROVED METHOD. <br />4.DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, <br />MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE <br />WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. <br />PERMANENT SIGNAGE NOTES: <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(3)(2) <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(3)(3) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 690.13(B) <br />& 706.15(C)(4) <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR <br />OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2022: 690.56(C)(2), <br />CFC 2022: 1204.5.3 <br />POWER TO THIS BUILDING IS <br />ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH <br />DISCONNECTS AS SHOWN <br />CAUTION: <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />16.00 AMPS <br />240.0 VAC <br />PHOTOVOLTAIC AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br />1410 N PARSONS PL, <br /> SANTA ANA, <br /> CA 92703 <br />APN:10046201 <br />DATE:11/2/2023 <br />KINGSTON <br />RESIDENCE <br />License#: C-10 1053344 <br />ADDRESS:2072 N MAIN ST <br /> FL 2, LOGAN <br /> UT 84341-1993 <br /> CSLB#: 1053344 <br />DESIGNER: OAV <br />CORE ENERGY GROUP. <br />E-2 <br />LOCATION OF EXISTING AC <br />DISCONNECT & PV LOAD <br />CENTER <br />WARNING! <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />PV INTERCONNECTION POINT. <br />LOCATION OF METER MAIN COMBO, AC <br />DISCONNECT, PV LOAD CENTER & STRING <br />INVERTER. <br />1410 N PARSONS PL <br />(N) SOLAR PANELS & OPTIMIZER <br />ON ROOF <br />(E) PV SYSTEM IS RSD COMPLIANT <br />(E) SOLAR PANELS & <br />MICRO-INVERTERS ON ROOF <br />W <br />S <br />U <br />N <br />S <br />W <br />E <br />P <br />T <br /> <br />A <br />V <br />E <br />PHOTOVOLTAIC SYSTEM <br />DC DISCONNECT <br />OPERATING VOLTAGE: 443.76 VDC <br />OPERATING CURRENT: 12.81 AMPS <br />MAX SYSTEM VOLTAGE: 501.44VDC <br />SHORT CIRCUIT CURRENT: 13.70 AMPS <br />LABEL LOCATION: INVERTER <br />PER CODE(S): CEC 2022: 690.53 <br />1410 N Parsons Pl - <br />2018164112/13/2023