Laserfiche WebLink
N1 <br />N1 <br />N1 <br />N1 <br />N1 <br />N1 <br />(N <br />) <br />4 <br />: <br />1 <br />2 <br />(N <br />) <br />4 <br />: <br />1 <br />2 <br />(N)4:12 <br />(N <br />) <br />4 <br />: <br />1 <br />2 <br />(N)4:12 <br />(N <br />) <br />4 <br />: <br />1 <br />2 <br />(N)4:12 <br />(N)4:12 <br />1 <br />(N)DORMER VENT DM-36 <br />LEGEND <br />ATTIC VENT CALCULATION <br />TOTAL ATTIC AREA 1150 <br />(SQ.FT.) <br />SQ.FT. <br />REQUIRED <br />SQ.IN. <br />REQUIRED <br />749 5.0 719.0 <br />VENT TYPE NET FREE <br />AREA SQ.IN QTY TOTAL SQ.IN. <br />1 DORMER 100 8 800 <br />0 2 0 <br />TOTAL 800 <br />800 > 719.0 <br />NOTE: <br />1. THE TOTAL NET FREE VENTILATING AREA SHALL NOT <br />BE LESS THAN 1150 OR 1300 WHEN A MIN OF 3 FEET <br />SEPARATION FROM EAVE VENTS TO GABLE/DORMER <br />VENTS ARE SHOWN. CLASS I OR II VAPOR BARRIER IS <br />INSTALLED ON THE WARM-IN-WINTER SIDE OF THE <br />CEILING. <br />NOTE: <br />PROVIDE 8 DORMERS <br />MANUFACTURER: LG OR SIMILAR <br />MODEL: LG400N2W-V5 <br />SOLAR PANEL SIZE: (L x W x H) <br />2,024mm x 1,024mm x 40mm <br />6.64' x 3.35' x 0.13' <br />MAX POWER: 400 W <br />REQ PV SYSTEM: 2,040 W <br />2,040 / 400= 5.1 = 6 SOLAR PANELS <br />(N) PV SYSTEM REQUIRED <br />2.04 kWdc MIN SIZE <br />4:12 PITCH <br />(N)ASPHALT SHINGLE ROOF <br />CLASS "A" <br />TIMBERLINE COOL SERIES-COOL <br />BARKWOOD/BROWN COLOR <br />ESR-3267 <br />CRRC # 0676-0041a <br />SOLAR REFLECTANCE 0.27 <br />THERMAL EMITTANCE 0.90 <br />SRI 28 <br />(N)BEDROOM (N)GREAT <br />ROOM <br />2 31 <br />THRESHOLD <br />SILL FLASHING, <br />CONTINUE 2" UP <br />EACH JAMB <br />CONCRETE SLAB <br />*TYPICAL TO <br />SLABS AND DECKS <br />BITUMINOUS PROTECTION BARRIER <br />BETWEEN THRESHOLD AND UNITIZED <br />FLASHING TO PREVENT GALVANIC <br />REACTION DOOR <br />FLASHING DETAILS @ DOORS <br />PLYWOOD <br />INSULATION <br /> # 2 - LAYERS TYPE "D" <br />PAPER <br />AND STUCCO WIRE <br /> STUCCO OVER <br />1/2" X 2" BACK DAM <br />OR BEVELED <br />WOOD SIDING <br />SLOPED TO <br />EXTERIOR <br />PEEL-AND-STICK <br />FLASHING <br />DRYWALL <br />WINDOW FLANGE <br />WINDOW <br />FLASHING DETAIL @ WINDOWSEMERGENCY EXIT <br />SLEEPING ROOMS MUST HAVE A WINDOW OR EXTERIOR DOOR FOR AN EMERGENCY EXIT: <br />- SILL HEIGHT NOT MORE THAN 44 INCHES ABOVE THE FLOOR <br />- 5.0 SQ.FT. MIN CLEAR NET OPENABLE AREA OF GRADE FLOOR <br />- 5.7 SQ. FT. MIN CLEAR NET OPENABLE AREA FROM THE FOURTH FLOOR TO THE <br />SECOND FLOOR ABOVE GRADE <br />- 24 INCHES MIN CLEAR OPENING HEIGHT <br />- 20 INCHES MIN CLEAR OPENING WIDTH <br />AND SHALL OPEN DIRECTLY INTO A PUBLIC STREET, ALLEY, YARD, OR EXIT COURT. <br />F.F. <br />5.0 SQ.FT.MIN CLEAR <br />OPENABLE AREA 5.0 SQ.FT.MIN CLEAR <br />OPENABLE AREA <br />MINIMUM SIZE WINDOW FOR <br />24" CLEAR WIDTH <br />MINIMUM SIZE WINDOW FOR <br />20" CLEAR WIDTH <br />1-HR FIRE RATED WALL AND OVERHANG 4 1-HR FIRE RATED WALL ASSEMBLY 5 <br />8" <br /> <br />m <br />i <br />n <br />PLYWOOD SHEARWALL PER <br />STRUCTURAL <br />2 LAYERS BUILDING TYPE "D"PAPER <br />7 8"STUCCO PLASTER <br />FINISH <br />R-15 INSULATION <br />26 GAGI GALV. WEEP SCREED <br />The weep screed at least 4-inches above <br />exposed earth or <br />2-inches above hardscape. see notes <br />1'-3" MIN <br />24 <br />" <br />M <br />I <br />N <br />7SLAB ON GRADE FOOTING <br />NOTES: <br />- Requirements for a 19-mil (No. 26 galvanized sheet steel gage) or 50 mil PVC weep <br />screed with a minimum 3-1/2 inch attachment flange that is capable of allowing <br />trapped water to escape from behind the stucco. <br />-The attachment flange at or below the sill/concrete interface. <br />- The weep screed at least 4-inches above exposed earth or 2-inches above hardscape. <br />4 <br />3 <br />12"m <br />i <br />n <br />VERTICAL DRYER VENT <br />PRODUCT DATA <br />product to vent or exhaust grease or liquid. <br /> Recommended use of this product is for exhaust of warm dry or slightly moist air only. Do not use thisNOTE: <br />nailing flange. Apply moisture retardant over nailing flange in accordance with standard lathing practice. <br />Affix dryer vent directly to structural members using galvanized fasteners one half inch in at each corner of the <br />Waterproofing Manual. <br />basis for detail whenever applicable as well as NRCA (National Roofing Contractors Association) Roofing and <br />Conditioning Contractors National Association) Architectural Manual, current edition, shall be used as a guide and <br />Installation shall be made in accordance with recognized sheet metal practices. SMACNA (Sheet Metal and Air <br />uneven substrate. <br />Before installing, ensure that the substrate is uniform and even. Do not install C & J Sheet Metal Products on <br />TIONINSTALLA <br />ASTM A653/A653M -G90 hot dipped galvanized steel, 26GA standard. <br />TERIALSSTANDARD MA <br />ATPRODUCT DA <br />C & J METAL PRODUCTS INC <br />6925 DOWNEY AVENUE LONG BEACH CA 90805 <br />VERTICAL DRYER VENT <br />Designed for roof top venting where standard thru-wall <br />discharge is not available. Built in concealed damper <br />stays closed when not in use. <br />NEW OR EXISTING ROOF <br />(N)C.J. PER PLANS <br />NEW OR EXISTING <br />2X STUDS <br />5 8" GYPSUM BOARD TYPE X (EACH SIDE) <br />FROM FLOOR TO UNDERSIDE <br />OF THE ROOF SHEATHING <br />OR 1-HR RATED LATH AND PLASTER <br />R-15 INSULATION <br />R-30 INSULATION <br />(N)PLYWOOD <br />(WHERE OCCURS) <br />2X FIRE BLOCKING <br />PERMITTED PROJECTIONS WITH A <br />FIRE SEPARATION DISTANCE OF LESS <br />THAN 5 FEET SHALL HAVE NOT LESS <br />THAN ONE-HOUR FIRE-RESISTIVE <br />CONSTRUCTION ON THE UNDERSIDE <br />PL <br />24" MIN <br />PER PLANS <br />12" <br />A-7 <br />ROOF PLAN & <br />SECTION <br />37-23 <br />08/2024 <br />J.L.P. <br />No. Description Date <br />Scale <br />Project number <br />Date <br />Drawn by <br />SCALE 1/4"=1'-0" <br />PROPOSED ROOF PLAN <br />613 S EASTBURY AVE, <br />COVINA CA 91723 <br />Owner <br />Property Address <br />Main House: <br />1506 E CLEMENSEN AVE <br />SANTA ANA, CA 92705 <br />ADU: <br />1506 E CLEMENSEN AVE # 2 <br />SANTA ANA, CA 92705 <br />PHONE: <br />NANCY CALTAGIRONE <br />DRYER VENT 6 <br />SCALE 1/4"=1'-0" <br />SECTION A-A <br />714-997-0313 <br />1506 E Clemensen Ave & <br />#212/12/2024