Laserfiche WebLink
12 <br />3 <br />' <br />-7 <br />" <br />103'-9" <br />10 <br />3 <br />' <br />-4 <br />" <br />40'-1" <br />25 <br />' <br />- <br />6 <br />" <br />8'-11" <br />1 <br />7 <br />' <br />- <br />4 <br />" <br />SATELLITE VIEW <br />SCALE: NTS <br />SCALE: NTS <br />COVER SHEET <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />CS <br />DATE: 2/17/2023 <br />1 <br />5 <br />3 <br />5 <br /> <br /> W <br /> <br />P <br />O <br />M <br />O <br />N <br />A <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />FE <br />L <br />I <br />P <br />E <br /> <br />E <br />L <br />I <br />Z <br />A <br />L <br />D <br />E <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />TROY STOKES <br />2491 ALLUVIAL AVE <br />#22 CLOVIS, CA 93611 <br />CONTRACTOR LIC#: #904259 <br />PHONE #: 559-797-2232 <br />GENERAL B,C10-ELECTRICAL <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 2/17/2023 00 <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />10 MODULES-ROOF MOUNTED - 3.900 KW DC, 3.534 KW AC, 1535 W POMONA ST, SANTA ANA, CA 92704 <br />GOVERNING CODES <br />ALL WORK SHALL CONFORM TO THE FOLLOWING CODES <br />1. 2022 CA BUILDING CODE <br />2. 2022 CA ELECTRICAL CODE <br />3. 2022 CA FIRE CODE <br />4. 2022 CA RESIDENTIAL CODE <br />5. ANY OTHER LOCAL AMENDMENTS <br />ROOF ACCESS POINT <br />ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS <br />THAT DO NOT REQUIRE THE PLACEMENT OF GROUND <br />LADDERS OVER OPENINGS SUCH AS WINDOWS OR <br />DOORS, AND LOCATED AT STRONG POINTS OF BUILDING <br />CONSTRUCTION IN LOCATIONS WHERE THE ACCESS <br />POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />2 <br />PV0.0 <br />3 <br />PV0.0 <br />N <br />PRO <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> LIN <br />E <br />GENERAL NOTES: <br />a. INSTALLATION OF SOLAR <br />PHOTOVOLTAIC SYSTEM SHALL BE <br />IN ACCORDANCE WITH NEC ARTICLE <br />690, AND ALL OTHER APPLICABLE <br />NEC CODES WHERE NOTED OR <br />EXISTING. <br />b. PROPER ACCESS AND WORKING <br />CLEARANCE AROUND EXISTING AND <br />PROPOSED ELECTRICAL <br />EQUIPMENT WILL COMPLY WITH <br />NEC ARTICLE 110. <br />c. ALL CONDUCTORS, INCLUDING THE <br />GROUNDING ELECTRODE <br />CONDUCTOR SHALL BE PROTECTED <br />FROM PHYSICAL DAMAGE IN <br />ACCORDANCE WITH NEC ARTICLE <br />250. <br />d. THE PV MODULES ARE CONSIDERED <br />NON-COMBUSTIBLE; THIS SYSTEM IS <br />UTILITY INTERACTIVE PER UL 1741 <br />AND DOES NOT INCLUDE STORAGE <br />BATTERIES OR OTHER <br />ALTERNATIVE STORAGE SOURCES. <br />e. ALL DC WIRES SHALL BE SIZED <br />ACCORDING TO [NEC 690.8] <br />f. DC CONDUCTORS SHALL BE WITHIN <br />PROTECTED RACEWAYS IN <br />ACCORDANCE WITH [NEC 690.31] <br />g. ALL SIGNAGE TO BE PLACED IN <br />ACCORDANCE WITH LOCAL <br />JURISDICTIONAL BUILDING CODE. <br />h. PV MODULES TO BE RATED UL 1703 <br />CLASS C FIRE RATING OR BETTER. <br />i. ALL EQUIPMENT TO BE CERTIFIED <br />BY A NATIONALLY RECOGNIZED <br />TESTING LABORATORY. <br />j. A 36" WIDE PATHWAY SHALL BE <br />PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING. <br />SYSTEM SIZE: 3.900 kW DC <br /> 3.534 kW AC <br />MODULE TYPE & AMOUNT: (10) CANADIAN SOLAR CS3N-390MS [BLK] <br />MODULE DIMENSIONS: (L/W/H) 76.4"X41.3"/1.38" <br />INVERTER: (10) ENPHASE ENERGY I7PLUS-72-2-US [240V] [240V] <br />INTERCONNECTION METHOD: BACKFEED IN MSP <br />UTILITY COMPANY: SCE <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />SCALE: 1/16" = 1'-0" <br />1 PLOT PLAN <br />CS <br />1535 W POMONA ST <br />FRONT OF HOUSE <br />M EXISTING EXTERIOR MAIN <br />SERVICE PANEL & POINT <br />OF INTERCONNECTION TIED <br />TO EXTERIOR UTILITY METER <br />MAIN <br />HOUSE <br />FENCE <br />ROOF ACCESS POINT <br />DRIVEWAY <br />ROOF #1 <br />(10) CANADIAN SOLAR CS3N-390MS <br />[BLK] <br />SLOPE: 23° <br />AZIM.: 210° <br />PRO <br />P <br />E <br />RT <br />Y <br /> <br />LI <br />NE <br /> <br />SHEET INDEX <br />CS COVER SHEET <br />A1.0 SITE PLAN <br />A2.0 MOUNTING DETAILS <br />E1.0 NOTES <br />E2.0 ELECTRICAL LINE DIAGRAM <br />P1.0 WARNING LABELS <br />SS1+EQUIPMENT SPECIFICATIONS <br />This item has been digitally signed <br />and sealed on May 17, 2023 <br />The scope of the plans is for the installation <br />of the solar photovoltaic system only and <br />the approval is subject to compliance with <br />all applicable city and state codes and <br />regulations regarding construction. The <br />approval of the plans does not constitute <br />any certification of the accuracy, <br />completeness, or building permit status of <br />the existing buildings and structures as <br />shown. <br />Bldg# 101115585 <br />Elec# 20180112 <br />Issued 06/26/23 <br />1535 W Pomona St <br />06/26/23