Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET NUMBER <br />DATE DESCRIPTION <br />VERSION <br />PV-6 <br />PROJECT NAME <br />UR04/27/2023 INITIAL RELEASE <br />HE <br />R <br />A <br />S <br />, <br /> <br />M <br />O <br />U <br />R <br />E <br />E <br />N <br />1 <br />4 <br />3 <br />0 <br /> <br />N <br /> <br />B <br />A <br />K <br />E <br />R <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />4 <br />0 <br />5 <br />2 <br />5 <br />1 <br />1 <br />3 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />ENERGY RENOVATION CENTER <br />11731 Sterling Avenue, Unit G <br /> Riverside, CA 92503 <br />LIC:- 1009326 <br />PH:- 8886040226 <br />pm@energyrenovationcenter.com <br />ELECTRICAL <br />CALCULATION <br />SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / MODEL #HANWHA Q.CELLS Q.PEAK DUO <br />BLK-G6+/AC (340W) MODULES <br />VMP 33.94 <br />IMP 10.02 <br />VOC 40.66 <br />ISC 10.52 <br />MODULE DIMENSION 68.50"L x 40.60"W x 1.57"D (In Inch) <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL #ENPHASE ENERGY IQ7PLUS-72-ACM-US <br />OR IQ7PLUS-72-E-ACM-US <br />NOMINAL OUTPUT VOLTAGE 240 VAC <br />NOMINAL OUTPUT CURRENT 1.21A <br />AMBIENT TEMPERATURE SPECS <br />WEATHER STATION: TUSTIN MCAF <br />RECORD LOW TEMP 2° <br />AMBIENT TEMP (HIGH TEMP 2%)31° <br />CONDUIT HEIGHT (ABOVE ROOF)7/8" <br />ROOF TOP TEMP 31° <br />CONDUCTOR TEMPERATURE RATE (ON ROOF)90° <br />CONDUCTOR TEMPERATURE RATE (OFF ROOF)75° <br />MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/°C <br />PERCENT OF VALUES NUMBER OF CURRENT <br />CARRYING CONDUCTORS IN EMT <br />.80 4-6 <br />.70 7-9 <br />.50 10-20 <br />ELECTRICAL CALCULATION <br />SCALE: NTS1 <br />ELECTRICAL NOTES <br />1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 AND 75 DEGREE C WET ENVIRONMENT. <br />3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. <br />5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL <br />APPLICABLE CODES AND STANDARDS. <br />6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM JUNCTION BOX TO COMBINER BO X: <br />AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT <br />PER CEC 310.15(B)(3)(c): (7/8"RULE) <br />EXPECTED WIRE TEMP (In Celsius)31° <br />TEMP. CORRECTION PER TABLE 310.15(B)(2)(a)0.96 <br />NO. OF CURRENT CARRYING CONDUCTORS 4 <br />CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)0.80 <br />CIRCUIT CONDUCTOR SIZE 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY 40A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B): <br />10.59A1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT <br />CURRENT <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(B)(2)(a) <br />30.72A TEMP. CORRECTION PER TABLE 310.15(B)(2)(a) X <br />CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a) X CIRCUIT <br />CONDUCTOR AMPACITY <br />RESULT SHOULD BE GREATER THAN (10.59A) OTHERWISE LESS THE ENTRY FOR <br />CIRCUIT CONDUCTOR SIZE AND AMPACITY <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM COMBINER BOX TO INTERCONNECTION: <br /># OF INVERTERS 14 <br />EXPECTED WIRE TEMP (In Celsius)31° <br />TEMP. CORRECTION PER TABLE 310.15(B)(2)(a)0.94 <br />NO. OF CURRENT CARRYING CONDUCTORS 3 <br />CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)1.00 <br />CIRCUIT CONDUCTOR SIZE 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY 35A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B): <br />21.18A1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT <br />CURRENT <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(B)(2)(a) <br />32.90ATEMP. CORRECTION PER TABLE 310.15(B)(2)(a) X <br />CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a) X CIRCUIT <br />CONDUCTOR AMPACITY <br />RESULT SHOULD BE GREATER THAN (21.18A) OTHERWISE LESS THE ENTRY FOR <br />CIRCUIT CONDUCTOR SIZE AND AMPACITY <br />1430 N Baker St <br />06/12/23