Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET NUMBER <br />DATE DESCRIPTION <br />VERSION <br />PV-7 <br />PROJECT NAME <br />UR04/27/2023 INITIAL RELEASE <br />HE <br />R <br />A <br />S <br />, <br /> <br />M <br />O <br />U <br />R <br />E <br />E <br />N <br />1 <br />4 <br />3 <br />0 <br /> <br />N <br /> <br />B <br />A <br />K <br />E <br />R <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />4 <br />0 <br />5 <br />2 <br />5 <br />1 <br />1 <br />3 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />ENERGY RENOVATION CENTER <br />11731 Sterling Avenue, Unit G <br /> Riverside, CA 92503 <br />LIC:- 1009326 <br />PH:- 8886040226 <br />pm@energyrenovationcenter.com <br />WARNING LABELS & <br />PLACARD <br />CAUTION ! <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />AT: MAIN SERVICE PANEL & UTILITY METER, <br />AC DISCONNECT & COMBINER BOX <br />MULTIPLE POWER SOURCEWARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />! <br /> WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />LABEL LOCATION: <br />EMT/CONDUIT RACEWAYS <br />(PER CODE: CEC690.31(D)(2) <br />PHOTOVOLTAIC POWER SOURCE <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />PRODUCTION METER <br />CEC 705.12(B)(3)(3) & CEC 690.59) <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE <br />2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS <br />ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE <br />LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS <br />USING EFFECTIVE WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE <br />EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND <br />WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND <br />THE ENVIRONMENT INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE <br />SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: CEC 706.15 <br />(C)(4) & CEC 690.13(B) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 16.94 AMPS <br /> 240 VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING <br />MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. <br />PER CODE(S):2022 CEC 690.56(C) :2022 CFC 1205.4.1 <br />! <br />4" <br />3" <br />PHOTOVOLTAIC AC DISCONNECT <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT / UTILITY METER <br />(PER CODE: CEC 690.13(B)) <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES TOTAL <br />RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN POWER <br />SUPPLY SHALL NOT EXCEED <br />AMPACITY OF BUSBAR <br />WARNING <br />LABEL LOCATION: <br /> POINTS OF CONNECTION/BREAKER <br />CODE: CEC 705.12(B)(3)(3) <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT <br />CEC 690.13(B) <br />LABEL LOCATION: <br />MSP (PER CODE: CEC 705.12(D) & <br />CEC 690.59 <br />CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />! <br />LABEL LOCATION: <br />SERVICE PANEL IF SUM OF <br />BREAKERS EXCEEDS PANEL RATING <br />CEC 705.12 (B)(3)(2) <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR <br />OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2022: 690.56(C)(2) <br />RAPID SHUTDOWN FOR <br />SOLAR PV SYSTEM <br />! <br />! <br />WARNING <br />THE DISCONNECTION OF THE <br />GROUNDED CONDUCTOR(S) <br />MAY RESULT IN OVERVOLTAGE <br />ON THE EQUIPMENT <br />! <br />LABEL LOCATION: <br />COMBINER BOX <br />PER CODE: CEC 690.31(E) <br />1430 N BAKER ST <br />MAIN SERVICE PANEL <br />WITH MAIN BREAKER <br />UTILITY METER <br />NON FUSED AC <br />DISCONNECT <br />COMBINER BOX <br />PV MODULES <br />1430 N Baker St <br />06/12/23