Laserfiche WebLink
© 2022 IRONRIDGE, INC. VERSION 3.6 FLUSH MOUNT INSTALLATION MANUAL - 2 <br />RATINGS <br />3URGXFWPDUNLQJVDUHORFDWHGRQWKH*URXQGLQJ/XJEROW <br />head. <br />MARKINGS <br />UL 2703 LISTED <br />Conforms to STD UL 2703 Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/ <br />Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels <br />• Max Overcurrent Protective Device (OCPD) Rating: 40A <br />• Max Module Size: 30.5 ft² <br />• 0RGXOH2ULHQWDWLRQ3RUWUDLWRU/DQGVFDSH <br />• 6\VWHP'HVLJQ/RDG5DWLQJ36)GRZQZDUG36)XSZDUG36)ODWHUDO <br />• $FWXDOV\VWHPVWUXFWXUDOFDSDFLW\LQFOXGLQJVSDQVDQGFDQWLOHYHUVDUHGH¿QHGE\3(VWDPSHGFHUWL¿FDWLRQOHWWHUV. <br />• &$026SHFL¿F'HVLJQ/RDGUDWLQJ36)GRZQZDUG36)XSZDUG36)ODWHUDO <br />&HUWL¿HGWR&6$7,/1R$3KRWRYROWDLF0RGXOH5DFNLQJ6\VWHPV <br />• /RDG5DWLQJ3$>36)@ <br />CLASS A SYSTEM FIRE RATING PER UL 2703 <br />• $Q\5RRI6ORSHZLWK0RGXOH7\SHV $OORZHGZLWKDQ\URRIVORSH$Q\PRGXOHWRURRIJDSLV <br />permitted, with no perimeter guarding required. <br />• 0RGXOH7\SHVDQG$OORZHGZLWK6WHHS6ORSH5RRIV •ƒ $Q\PRGXOHWRURRIJDSLVSHUPLWWHGORZHGJH <br />guarding (Trim) required <br />• &ODVV$UDWHG39V\VWHPVFDQEHLQVWDOOHGRQ&ODVV$%DQG&URRIVZLWKRXWDႇHFWLQJWKHURRI¿UHUDWLQJ <br />CLASS B SYSTEM FIRE RATING PER UL 2703 <br />• 0RGXOH7\SHVDQG$OORZHGZLWK6WHHS6ORSH5RRIV •ƒ $Q\PRGXOHWRURRIJDSLVSHUPLWWHGZLWKQR <br />perimeter guarding required <br />WATER SEAL RATINGS: <br />• 8/ )ODVKIRRW$OO7LOH+RRN.QRFNRXW7LOH)ODVKYXH/0RXQW <br />• 7$6 $  )ODVKIRRW$OO7LOH+RRN.QRFNRXW7LOH)ODVKYXH/0RXQW4EDVH <br />• Tested and evaluated without sealant. <br />• $Q\URR¿QJPDQXIDFWXUHUDSSURYHGVHDODQWLVDOORZHG5DWLQJVDSSOLFDEOHIRUURRIVORSHVEHWZHHQDQG <br />STRUCTURAL CERTIFICATION <br />• 'HVLJQHGDQG&HUWL¿HGIRU&RPSOLDQFHZLWKWKH,QWHUQDWLRQDO%XLOGLQJ&RGH $6&(6(, <br />FLORIDA PRODUCT APPROVAL #FL29843 <br />• &RQIRUPVWR7$67$6 $ <br />• $SSURYHGIRULQVWDOODWLRQERWKLQVLGHDQGRXWVLGH+LJK9HORFLW\+XUULFDQH=RQHV +9+= <br />• $OORZDEOHGHVLJQSUHVVXUHXSWR36) <br />• Additional details and full list of approved components can be found +HUH <br /> <br />© 2022 IRONRIDGE, INC. VERSION 3.6 FLUSH MOUNT INSTALLATION MANUAL - 3 <br />ATTACHMENTS <br />BONDING HARDWARE TORQUE VALUES <br />Please refer to each attachment's individual section for full details <br />on all torque values and instructions. <br /> ☐%RQGLQJ+DUGZDUH1XWV 6RFNHW LQOEV <br /> ☐$OO7LOH+RRN&DUULDJH%ROWV 6RFNHW LQOEV <br /> ☐)ODW5RRI$WWDFKPHQW1XWV ´6RFNHW LQOEV <br /> ☐/\Q[6HW6FUHZ +H['ULYH LQOEV <br /> ☐/\Q[)ODQJH1XW 6RFNHW LQOEV <br /> ➢If using previous version of Integrated Grounding Mid Clamps, <br />End Clamps, Expansion Joints and for a list of approved 3rd party <br />components please refer to Alternate Components Addendum <br />(Version 1.9) <br />ATTACHMENTS <br />40/0RXQWFlashVue <br />404XLFN+RRNDQG <br />Flashing (optional) <br />404%DVH7LOH <br />$OO7LOH+RRNDQG <br />Flashing (optional) <br />FlashFoot2 <br />COMPOSITION SHINGLE <br />TILE <br />407LOH5HSODFHPHQW <br />40&ODVVLF&RPS <br />Mount404%DVH <br />404%DVH0RXQWFlat Roof Attachment <br />LOW SLOPE ROOF <br />40&ODVVLF0RXQW <br />Shake <br />404EDVH6KDNH <br />Slate - Metal Shingle <br />ADDITIONAL ROOF TYPES <br />PRE-INSTALLATION <br /> ☐Verify module compatibility. See 3DJH for info. <br />TOOLS REQUIRED <br /> ☐Cordless Drill (non-impact) <br /> ☐Impact Driver (for lag bolts) <br /> ☐Torque Wrench (0-250 in-lbs) <br /> ☐´Socket <br /> ☐6RFNHW <br /> ☐6RFNHW <br /> ☐'ULOO%LW <br /> ☐'ULOO%LW <br /> ☐'ULOO%LW <br /> ☐T30 Bit <br /> ☐&KDQQHO/RFN3OLHUV <br /> ☐#3 Phillips Bit <br /> ☐+H[%LW <br />40/\Q[0HWDO5RRI <br />Attachment <br />407LOH&RQGXLW <br />Penetration <br />40&RPSRVLWLRQ <br />Conduit Penetration <br />.QRFNRXW7LOH <br />1621 W Avalon <br />Ave08/07/23