Laserfiche WebLink
ATTACHMENT LAYOUT <br />SCOPE: <br />2.40 KW DC Roof Mounted <br />PV Electrical System <br />6 - Ureco 400W PV Modules <br />6 - IQ8+ Enphase Microinverters <br />DATE:03/10/2023 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />CUSTOMER INFORMATION <br />BUILDING INFO: <br />ONE STORY BUILDING <br />ROOF TYPE: COMPOSITION SHINGLE <br />ROOF STRUCTURE: <br />2''X4'' RAFTERS 24'' O/C <br />MOUNTING SYSTEM: <br />IRONRIDGE RACKING <br />PARCEL NUMBER: 10936105 <br />LOT AREA: 6,272 SQFT <br />LIVING AREA: 1,139 SQFT <br />COMPANY NAME: SKYSOLARPRO <br />ANDREY LITVINOV: #867980 TYPE: C10 <br />DATE: 11/30/2023 <br />ADDRESS: 11208 DONA LOLA DRIVE <br />STUDIO CITY, CA 91604 <br />PHONE: (323) 428-4892 <br />SIGNATURE <br />NAME: PET MARTINEZ <br />ADDRESS: 1705 W CUBBON ST, <br />SANTA ANA, CA 92703 <br />CITY OF SANTA ANA <br />UTILITY: SCE <br />PV-4 <br />SOLAR ARRAY MOUNTING RAIL TYPE: IRONRIDGE XR10 RACKING <br />SOLAR ARRAY ATTACHMENT TYPE: FLASH FOOT2 <br />ATTACHMENT SPACING: 72'' MAX <br />FRAMING: RAFTERS 2'' x 4'' @ 24'' O.C <br />FINISHED ROOF SURFACE IS ONE LAYER OF COMPOSITION SHINGLE. <br />WIND SPEED: 110 mph FOR EXPOSURE C <br />SNOW LOAD: 0 psf <br />72'' 24'' <br />NOTE TO INSTALL: VERIFY THE ROOF FRAMING INFO <br />BEFORE INSTALLATION AND NOTIFY THE EOR IF THERE IS <br />ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND <br />FOLLOWINGS: 2x 4 RAFTERS @ 24" OC SPACING WITH MAX <br />UNSUPPORTED SPAN EQUAL OR LESS THAN 6 FT <br />1705 W Cubbon St <br />04/14/23