Laserfiche WebLink
120/240V <br />1-PH, 3W <br />INCOMING <br />UTILITY <br />SERVICE <br />MAIN <br />BREAKER <br />120/240V <br />1-PH, 3W <br />INCOMING <br />UTILITY <br />SERVICE <br />Ω <br />M <br />5 <br />13 <br />6 <br />10 <br />8 <br />5 <br />7 <br />911 <br />NFT <br />40 <br />14 <br />15 <br />12 <br />3 <br />JUNCTION <br />BOX <br />3 <br />4 <br />4A 4 <br />(N) ENPHASE ENCHARGE  10T <br />5 <br />15 4 <br />CE <br />L <br />L <br />MO <br />D <br />E <br />M <br />ESS HOLD DOWN KIT BRHDK125 IS <br />REQUIRED PER <br />NEC 710.15 <br />HOLD DOWN KIT FOR PV <br />BREAKERS <br />6 <br />=== <br />=== <br />(BRANCH 1) <br />(BRANCH 2) <br />1 <br />1 <br />2 <br />2 <br />1 BRANCH OF 07 <br />PV MODULES <br />1 BRANCH OF 06 <br />PV MODULES <br />2 <br />1 <br />2 <br />1 <br />DATE: <br />SHEET NAME: <br />SHEET NUMBER: <br />DESIGNED BY: <br />DATE/DESIGNERREV. <br />1 <br />2 <br />3 <br />CUSTOMER INFORMATION: <br />SERGIO SEGURA <br />1817 MERIDAY LN <br />SANTA ANA, CA 92706 <br />(714) 904-4946 <br />12/12/2023 <br />TDAUPRAT <br />PVDC ­ 210211 <br />- <br />- <br />- <br />PV - 4.0 <br />ELETRICAL <br />GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE <br />TO BE MINIMUM PROTECTION OF BARE ARMOR SHEATHED CABLE, # 8 AWG. <br />MINIMUM. <br />NOTE: <br />- THIS SYSTEM IS DESIGNED, ENGINEERED AND EQUIPPED WITH A RAPID SHUTDOWN <br />FUNCTION FOR THE ENTIRE PV/ENERGY STORAGE SYSTEM <br />- THERE IS ONE SINGLE POINT, EXTERNALLY OPERABLE AND LOCKABLE SWITCH <br />THAT IS IDENTIFIED AS "RAPID SHUTDOWN SWITCH" (RSS) THAT WILL SHUT DOWN <br />AND DE-ENERGIZE THE ENTIRE PV/ESS SYSTEM INSTANTANEOUSLY <br />- THE RAPID SHUTDOWN SWITCH SHUTS DOWN AND OPENS ALL CIRCUITS TO THE <br />BATTERY-ENERGY STORAGE SYSTEM, SOLAR PV, POWER TO THE GRID AND POWER <br />TO THE BACKED UP LOADS SIMULTANEOUSLY <br />- THIS SWITCH IS THE ONLY WAY TO INSTANTLY DE-ENERGIZE THE ENTIRE PV/ESS <br />SYSTEM FROM A SINGLE IDENTIFIABLE POINT <br />ELECTRICAL EQUIPMENT LIST <br /># ITEM DESCRIPTION QTY.  <br />1 (N) PV MODULE 13 <br />1(N) PV BREAKER 20A-2P, 240V6 <br />1(N) ENPHASE: <br />IQ COMBINER 4 <br />ENPHASE AC COMBINER BOX W/ IQ+ <br />CONSOLIDATES INTERCONNECTION <br />INTO A SINGLE ENCLOSED <br />STREAMLINE <br />4 <br />(N) ENPHASE: <br />IQ COMBINER 4 <br />BREAKERS <br />20A/2P BREAKER FOR SOLAR <br />4A 10A/2P OR 15A/2P BREAKER FOR <br />ENVOY MONITORING & REVENUE <br />GRADE METER <br />2 <br />1 <br />(N) MICRO-INVERTER2 13 <br />2(N) JUNCTION BOX3 <br />ENPHASE ENERGY: IQ8PLUS-72-2-US <br />97% CEC EFFICIENCY @ 240 Vac <br />290 Wac CONTINUOUS <br />MAX.OUTPUT CURRENT 1.21 Aac <br />MAX.INPUT CURRENT 15 Adc <br />EQUIPPED W/ RAPID SHUTDOWN <br />(N) AC DISCONNECT <br />SQUARE D,DU221RB GENERAL OR EQ. <br />USE SWITCH, 30A, 2P-240V, BLADE <br />TYPE NON-FUSIBLE <br />15 1 <br />1(N) BACKUP LOAD <br />PANEL8 <br />9 1 <br />SQUARE D OR EQ. 125A, 240V, 1ɸ, <br />NEMA 3R RATED SURFACE MOUNT <br />(N) ENPHASE IQ <br />SYSTEM <br />CONTROLLER 2 <br />EP200G101-M240US01 200A MAX, <br />240VAC, 1ɸ, ENPHASE IQ SYSTEM <br />CONTROLLER 2 <br />1(N) ESS BREAKER 20A-2P, 240V10 <br />7 1(N) ENPHASE <br />ENCHARGE 10T <br />ENPHASE ENCHARGE 10T <br />STORAGE (ESS) <br />16A RATED OUTPUT <br />1(N) SUB PANEL <br />MAIN BREAKER 60A-2P, 240V11 <br />1 <br />(N) IQ SYSTEM <br />CONTROLER <br />BREAKER <br />60A-2P, 240V13 <br />1(N) CT METER CONSUMPTION MONITORING CT <br />(PAIR)12 <br />1(N) RAPID <br />SHUTDOWN SWITCH <br />ROTARY ACTUATOR, 2 POLE, 600 V, <br />16A, IP66, SCREW, FRONT MOUNT, <br />RAPID SHUTDOWN <br />14 <br />1MAIN SERVICE <br />PANEL5 <br />UPGRADING EXISTING <br />100A MAIN PANEL TO (N)  225A MAIN <br />PANEL W/ 200A MAIN BREAKER <br />PER CEC 705.12 (B)(3)(2) <br />MSP BUS BAR =225A <br />225A x 1.2 = 270A <br />LARGEST OCPD : 270A - 200A = 70A <br />PV SYSTEM: 13*1.21*1.25 = 19.66A (20A PV BREAKER) <br />BATTERIES : 16A*1*1.25 = 20A <br />TOTAL BACKFEED = 19.66A + 20A = 39.66A = 40A  <br />SOLADECK UL LISTED <br />WATER-TIGHT NEMA 3R RATED <br />RELOCATE ESSENTIAL LOADS FROM BUSBAR IN <br />MSP TO NEW 125A SUBPANEL. LOADS RELOCATED <br />MORE THAN 6' REQUIRE COMBO AFCI BREAKERS. <br />ATTENTION: TO PREVENT COMPLICATION BE SURE TO POWER DOWN <br />SYSTEM CONTROLLER 2 BEFORE CONNECTION THE SHUTDOWN <br />SWITCH <br />ESS NOTES: <br />*SINGLE LARGEST BREAKER IN MAIN PANEL CANNOT EXCEED THE <br />(ESS) STORAGE OUTPUT CAPACITY (20A) PER NEC 710.15. <br />*LRA OF LARGEST LOAD IN MAIN PANEL CANNOT EXCEED THE <br />(ESS) STORAGE OUTPUT CAPACITY (24.6A) PER NEC 710.15, <br />INSTALL SOFT START DEVICE TO MEET COMPLIANCE. <br />*BASELINE LOAD OF MAIN PANEL CANNOT EXCEED THE (ESS) <br />STORAGE OUTPUT CAPACITY (16A) PER NEC 710.15. <br />x________________ <br />JOHN RADLEIGH <br />VOLTAIC CONSTRUCTION, <br />LLC25186 HANCOCK AVE UNIT <br />230 MURRIETA, CA 92562 <br />(310) 709-0059 <br />CONSTRUCTION@VOLTAICNOW.COM <br />CSLB# 1096383 (B/C10) <br />CANADIAN SOLAR CS6R-395MS-HL <br />OPEN CIRCUIT VOLTAGE = 36.6VDC <br />MAX.POWER VOLTAGE = 30.06VDC <br />SHORT CIRCUIT CURRENT = 13.77A <br />MAX. POWER CURRENT = 12.91A <br />KEY NOTES <br />SOLID BARE E.G.C. (FREE-AIR) MOUNTED UNDER ARRAY PER NEC <br />250.120(C): WHERE CONDUCTORS & GROUND WIRE ARE RUN EXPOSED <br />ON FROM ARRAY TO J-BOX, CONDUCTORS & BARE GROUND WIRE SHALL <br />BE CONCEALED INSTALL IN CONDUIT <br />PER CEC ARTICLE 690.35 INVERTER GROUND FAULT PROTECTION <br />PROVIDED ALL GROUNDS AND NEUTRALS BONDED TO EXISTING <br />GROUNDING CONDUCTOR W/ IRREVERSIBLE CRIMP CONNECTOR <br />BACKFED BREAKERS MUST BE LOCATED @ OPPOSITE END OF <br />BUS BAR FROM MAIN BREAKER OR MAIN LUG ON GRID SIDE. <br />WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY <br />INTERCONNECTION, BREAKER SHALL NOT READ 'LINE OR LOAD'. <br />PER CEC 250.64(C): CONDUCTOR SPLICES ONLY ALLOWED WITH <br />COMPRESSION CONNECTORS OR EXOTHERMIC WELDING <br />ALL GROUNDS AND NEUTRALS BONDED TO EXISTING <br />GROUNDING CONDUCTOR W/ IRREVERSIBLE CRIP CONNECTOR. <br />VERIFY (E) UFER GROUND NEAR MSP. IF (E) UFER IS NOT <br />ACCESSIBLE OR VERIFIABLE , INSTALL A NEW 5/8"Ø X 8' LONG <br />GROUNDING ROD AND BOND SOLAR SYSTEM EQUIPMENT <br />GROUNDING ACCORDINGLY. <br />1817 W Meriday Ln- <br />201819032/22/2024